Search    ENTER KEYWORD
MSDS Material Safety Data Sheet
CAS

7487-88-9

File Name: montereyagresources_com---MagSulfHeptahydra-Valudor-m.asp
                           Valudor Products

MATERIAL SAFETY DATA SHEET
Product Name Magnesium Sulfate Heptahydrate
Supplier Valudor Products
1728 Hawk View Drive
Encinitas, CA 92024
Telephone (760) 635 9051
Emergency Telephone 1 (800) CHEMTRAC

PRODUCT IDENTIFICATION
Product Name Valumag 7
Molecular Formula MnSO4 路 7H20
CAS Number 7487-88-9


PHYSICAL PROPERTIES
Appearance Transparent crystals
Odor No Odor
Melting Point 2055F
Solubility in Water Highly soluble in water

HEALTH HAZARD INFORMATION

Skin No adverse effects expected but may cause minor skin
irritation.
Eyes No adverse effects expected but dust may cause mechanical
irritation.
Inhalation Dust may be slightly irritating. Sore throat or coughing may
occur.
Swallowing Since magnesium salts are slowly absorbed, abdominal pain,
vomiting and diarrhea may be the only symptoms. However, if
elimination is blocked by bowel blockage or other reasons,
CNS depression, lack of reflexes, hypocalcemia (deficiency of
calcium in the blood) may occur.




1
FIRE AND EXPLOSION HAZARD INFORMATION

Not considered to be a fire or explosion hazard.

Flash Point Not applicable.
Flammable Limits Not flammable.
Extinguishing Media Use any means suitable for extinguishing surrounding fire.


REACTIVITY DATA
Stability Stable under ordinary conditions of use and storage.
Hazardous Decomposition Oxides of sulfur and the contained metal.
Products
Polymerization Will not occur.
Incompatibilities Phosphates, ethoxy ethyl alcohols, tartrates, alkali metals.


FIRST AID MEASURES
Swallowing Give several glasses of water to drink to dilute. If large
amounts were swallowed, get medical advice.
Skin Remove any contaminated clothing. Wash skin with soap and
water for at least 15 minutes. Get medical attention if irritation
develops or persists.
Eyes Wash thoroughly with running water. Get medical advice if
irritation develops.
Inhalation Remove to fresh air. Get medical attention for any breathing
difficulty.
Note to Physician IV administration of calcium gluconate will partially reverse
the effects of acute magnesium toxicity. Ventricular support
with calcium chloride infusion and mannitol forced diuresis
has also been successful.

EXPOSURE CONTROLS AND PERSONAL PROTECTION INFORMATION

Skin Protection: Wear protective gloves and clean body-covering
Personal Protective Equipment
clothing.
Eye Protection: Use chemical safety goggles. Maintain eye wash
fountain and quick-drench facilities in work area.
A system of local and/or general exhaust is recommended to keep
Ventilation
employee exposures as low as possible. Local exhaust ventilation is
generally preferred because it can control the emissions of the
contaminant at its source, preventing dispersion of it into the general
work area. Please refer to the ACGIH document, Industrial
Ventilation, A Manual of Recommended Practices, most recent
edition, for details.


2
For conditions of use where exposure to dust or mist is apparent and
engineering controls are not feasible, a particulate respirator (NIOSH
type N95 or better filters) may be worn. If oil particles (e.g.
lubricants, cutting fluids, glycerine, etc.) are present, use a NIOSH
type R or P filter. For emergencies or instances where the exposure
levels are not known, use a full-face positive-pressure, air-supplied
respirator. WARNING: Air-purifying respirators do not protect
workers in oxygen-deficient atmospheres.

Airborne Exposure Limits: None established.


ENVIRONMENTAL AND DISPOSAL INFORMATION
Waste Disposal Whatever cannot be saved for recovery or recycling should be
managed in an appropriate and approved waste disposal
facility. Processing, use or contamination of this product may
change the waste management options. State and local
disposal regulations may differ from federal disposal
regulations. Dispose of container and unused contents in
accordance with federal, state and local requirements.
Environmental Effects No information found.


TOXICOLOGICAL INFORMATION
No LD50/LC50 information found relating to normal routes of occupational exposure.
REGULATORY INFORMATION
Chemical Weapons Convention: No TSCA 12(b): No CDTA: No
SARA 311/312: Acute: Yes Chronic: Yes Fire: No Pressure: No
SARA 302: No

SHIPPING INFORMATION

Not regulated.


NPFA RATINGS:

Health: 1
Flammability: 0
Reactivity: 0

All information in this MSDS was obtained form sources we believe are reliable. However, the
information is provided without any warranty or representation, expressed or implied, regarding
its accuracy.




3

Search    ENTER KEYWORD
ALL Chemical Property And Toxicity Analysis PAGES IN THIS GROUP
NAMECAS
montereyagresources_com---CropOilCon-m.asp N/A
montereyagresources_com---CutrinePluGra-m.asp 12069-69-1 141-43-5
montereyagresources_com---Dimethoate4EC-m.asp 60-51-5
montereyagresources_com---DitracRatMouBait-m.asp 82-66-6
montereyagresources_com---DitrAllWeCk1101m.asp 82-66-6
montereyagresources_com---DitrSpSzBlx1101m.asp 82-66-6
montereyagresources_com---DitrTracPow1001m.asp 82-66-6
montereyagresources_com---Endosulfan3EC-m.asp 115-29-7
montereyagresources_com---Envirosul-Iron22-MSDS.asp 1309-37-1 7704-34-9
montereyagresources_com---FastraAllWeaBlox-m.asp 63333-35-7
montereyagresources_com---FastracPlacePacs-m.asp 63333-35-7
montereyagresources_com---FeedGra_MinGra-m.asp 7446-19-7
montereyagresources_com---FerSulHydrate-m.asp 7782-63-0 7720-78-7
montereyagresources_com---FeSulfHeptahydra-Valudor-m.asp 7720-78-7
montereyagresources_com---FinalRodenticideRTUPlacePac-m.asp 56073-10-0
montereyagresources_com---FoliCal-m.asp N/A
montereyagresources_com---Granubor2-14-m.asp N/A
montereyagresources_com---GranusolCu30-m.asp N/A
montereyagresources_com---GranusolFe50-03-m.asp 8047-67-4 14808-60-7 112926-00-8
montereyagresources_com---GranusolMn35-03-m.asp 7439-96-5 112926-00-8 14808-60-7
montereyagresources_com---GreenMatchO-m.asp 5989-27-5
montereyagresources_com---IgnitorRTU-m.asp N/A
montereyagresources_com---IndSulTecMGPow-m.asp N/A
montereyagresources_com---KaligreenOtsuka-m.asp 298-14-6
montereyagresources_com---LineMaster-m.asp N/A
montereyagresources_com---MagSulfHeptahydra-Valudor-m.asp 7487-88-9
montereyagresources_com---ManganousOxideErachem-0704-m.asp 1344-43-0
montereyagresources_com---MarkItBlue-m.asp N/A
montereyagresources_com---MarkItRed0405m.asp 64-19-7
montereyagresources_com---Maximo361-m.asp N/A
montereyagresources_com---MediaBlitz-m.asp 7758-98-7 7733-02-0
montereyagresources_com---MonCobSul33-m.asp 10124-43-3
montereyagresources_com---MonCopAll5-m.asp 7758-98-7
montereyagresources_com---MonGranManSul-m.asp 10034-96-5
montereyagresources_com---MonH20Blue-m.asp N/A
montereyagresources_com---MonoPlexPlus1-m.asp 7758-99-8 7758-98-7 7720-78-7 10034-96-5 7446-19-7 7733-02-0
montereyagresources_com---MonSodMol39_7-m.asp 7631-95-0
montereyagresources_com---MontereyAg-Product_Guide2008.asp N/A
montereyagresources_com---MSMA_6_Plus-m.asp 2163-80-6
montereyagresources_com---Nordox75WG-m.asp 1317-39-1
montereyagresources_com---OdorMask-m.asp 119-36-8
montereyagresources_com---Oxzinal-m.asp N/A
montereyagresources_com---PAL-m.asp N/A
montereyagresources_com---PCQBait-0303-m.asp 82-66-6
montereyagresources_com---PoaConstrictor-m.asp 26225-79-6
montereyagresources_com---PureIronSulSol-m.asp 7720-78-7
montereyagresources_com---PygCroProEC14-m.asp 008003-34-7
montereyagresources_com---QuikFire-m.asp N/A
montereyagresources_com---QuintoxMouseSeed-m.asp 67-97-0
montereyagresources_com---QuintoxRatMouBait-m.asp 67-97-0

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com | Ads link:HBCCHEM.INC