LORD CORP -- CHEMLOK 855 ELASTOMER ADHESIVE, 98550W
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BXRPT
MSDS NAME: CHEMLOK 855 ELASTOMER ADHESIVE, 98550W
Responsible Party
Name: LORD CORP
Address: 2000 WEST GRANDVIEW BLVD
City: ERIE PA 16514
Info Phone: 814-868-3611
Emergency Phone Number: 814-763-2345
Preparer's Name: KMB
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LORD CORP
Address: 2000 W GRANDVIEW BLVD
Box: 10038
City: ERIE PA 16514
Phone: 814-868-3611
Name: LORD CORPORATION, CHEMICAL PRODUCTS DIVISION
Address: 2000 WEST GRANDVIEW BLVD
City: ERIE PA 16514-0038
Phone: 814-868-3611
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE: SKIN & EYE IRRIT. MAY CAUSE HDCH & NAUS. IN
ELEVATED TEMP APPLICATNS, PROD MAY RELEASE VAPS THAT MAY PRODUCE CYANOSIS IN
ABSENCE OF SUFFICIENT VENT/ADEQ RESP PROT. CHRONIC: MAY CAUSE DERM. MAY
AFFECT GI SYS. IARC HAS IDENTIFIED PROPRIETARY CURATIVE IN PROD AS "ANIMAL
SUSPECTED" CARCIN, GROUP 3, (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: HLTH HAZ: WHICH DOWNGRADES A PREVIOUS NCI
REPORT OF IT AS AN "ANIMAL POSITIVE" CARCINOGEN.
Medical Cond Aggravated By Exposure: CHRONIC DISEASES OF THE SKIN, THE EYES,
AND THE GASTROINTESTINAL TRACT.
First Aid: INHAL: MOVE PERS TO FRESH AIR. RESTORE BRTHG BY ARTF RESP IF NEC.
TREAT SYMPTOMATICALLY. CONSULT MD. EYES: FLUSH IMMED W/LGE AMTS OF WATER FOR
AT LEAST 15 MIN, HOLDING EYELIDS OPEN WHILE FLUSHING. GET PROMPT MED ATTN.
SKIN: FLUSH CONTAM SKIN & CLTHG W/LGE AMTS OF WATER. REMOVE CONTAM CLTHG.
WASH AFFECTED SKIN AREAS W/SOAP & WATER. CONSULT MD IF IRRIT PERSISTS.
INGEST: DRINK 1-2 GLASSES (SUP DAT)
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: EVACUATE NON-ESSENTIAL PERSONNEL. AVOID BREATHING
VAPORS. VENTILATE AREA. NOTIFY APPROPRIATE AUTHORITIES, IF NECESSARY. CONTAIN
AND REMOVE WITH INERT ABSORBENT MATERIAL. AVOID CONTACT.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISP SHOULD BE DONE I/A/W FED (40CFR PART 261), STATE
& LOC ENVIRONMENTAL CTL REGS. BEFORE ATTEMPTING CLEAN-UP, REFER TO HAZ
CAUTION INFO IN OTHER SECTIONS OF MSDS. IF WASTE IS DETERMINED TO BE HAZ, U
SE LICENSED HAZ WASTE TRANSPORTER & DISP FACILITY.
Handling And Storage Precautions: KEEP CLOSURE TIGHT AND CONTAINER UPRIGHT TO
PREVENT LEAKAGE. STORE DRUM OUT OF SUN AND AWAY FROM HEAT. STORE ONLY IN
WELL-VENTILATED AREAS.
Other Precautions: DO NOT GET IN EYES. AVOID SKIN CONTACT. PREVENT PROLONGED OR
REPEATED BREATHING OF VAPOR OR SPRAY MISTS. DO NOT HANDLE UNTIL THE
MANUFACTURER'S PRECAUTIONS HAVE BEEN READ AND UNDERSTOOD. KEEP FROM FRE
EZING.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point Text: >200F,>93C
Extinguishing Media: CARBON DIOXIDE, DRY CHEMICAL, WATER FOG, FOAM.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). IF WATER IS USED, FOG NOZZLES ARE PREFERABLE.
Unusual Fire/Explosion Hazard: KEEP CONTRS TIGHTLY CLSD. CLSD CONTRS MAY
RUPTURE WHEN EXPOS TO EXTREME HEAT. WATER MAY BE USED TO COOL CLSD CONTRS TO
PREVENT PRESS BUILD-UP & POSS (SUP DAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED CHEMICAL/MECHANICAL FILTER
RESPIRATOR DESIGNED TO REMOVE A COMBINATION OF PARTICULATES & ORGANIC
VAPOR IF OCCUPATIONAL LIMITS ARE EXCEEDED. USE NIOSH/MSHA APPROVED AIRLINE
TYPE RESPIRATORS OR HOODS IN CONFINED AREAS.
Ventilation: SUFFICIENT VENT, IN PATTERN & VOL, SHOULD BE PROVIDED TO KEEP
AIR CONTAMINANT CONC BELOW APPLIC EXPOS LIM. ALL (SUP DAT)
Protective Gloves: NEOPRENE, NITRILE OR RUBBER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: USE DISPOSABLE/IMPERVIOUS CLTHG IF WORK CLTHG
CONTAM IS LIKELY. REMOVE & WASH CONTAM CLTHG BEFORE REUSE.
Work Hygienic Practices: WASH HANDS BEFORE EATING, SMOKING/USING THE WASH ROOM.
DO NOT SMOKE IN ANY CHEMICAL HANDLING OR STORAGE AREA.
Supplemental Safety and Health: USERS OF THE "L" VERSION OF TO CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). EXPLO HAZ: AUTO IGNIT/EXPLO. FIRST AID PROC:
OF WATER/MILK TO DILUTE. DO NOT INDUCE VOMIT. CONSULT MD/POIS CTL CTR IMMED .
TREAT SYMPTOMATICALLY. VENT: APPLICATN AREAS SHOULD BE VENT I/A/W OSHA REG
29CFR PART 1910.94.
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: (SEE ING2)
Vapor Density: HVR/AIR
Spec Gravity: 1.138
Evaporation Rate & Reference: SLOWER THAN ETHER
Solubility in Water: DISPERSED
Appearance and Odor: GREEN/BLACK LIQUID WITH MILD ODOR
Percent Volatiles by Volume: 64
=======================================================
Reactivity Data
=======================================================
Stability Indicator: NO
Stability Condition To Avoid: HIGH TEMPERATURES. PRODUCT IS NOT STABLE UNDER
NORMAL STORAGE CONDITIONS.
Materials To Avoid: STRONG ACIDS, BASES AND STRONG OXIDIZERS.
Hazardous Decomposition Products: CARBON DIOXIDE, CARBON MONOXIDE, CHLORINE,
HYDROGEN CHLORIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CHEMLOK 855 ELASTOMER ADHESIVE, 98550W
Assigned IND: Y
Company: LORD CORP
Street: 2000 W GRANDVIEW BLVD
PO Box: 10038
City: ERIE PA
Zipcode: 16514
Health Emergency Phone: 814-763-2345
Label Required IND: Y
Date Of Label Review: 05/26/1995
Status Code: C
Label Date: 05/26/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: WARNING
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: COMBUSTIBLE. ACUTE: SKIN AND EYE IRRITATION. MAY CAUSE
HEADACHE AND NAUSEA. IN ELEVATED TEMPERATURE APPLICATIONS, PRODUCT MAY
RELEASE VAPORS THAT MAY PRODUCE CYANOSIS IN ABSENCE OF SUFFICIENT VENTILAT
ION OR ADEQUATE RESPIRATORY PROTECTION.CHRONIC: MAY CAUSE DERMATITIS. MAY
AFFECT THE GASTROINTESTINAL SYSTEM.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.