ITW DEVCON CORP -- UNDERWATER REPAIR PUTTY HARDENER, 11800
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBFDB
MSDS NAME: UNDERWATER REPAIR PUTTY HARDENER, 11800
Kit Part: Y
Responsible Party
Name: ITW DEVCON CORP
Address: 30 ENDICOTT ST
City: DANVERS MA 01923
Info Phone: 508-777-1100
Emergency Phone Number: 800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DEVCON CORP
Address: 30 ENDICOTT ST
City: DANVERS MA 01923-3753
Phone: 1-508-777-1100
Name: ITW DEVCON CORP
Address: 30 ENDICOTT ST
City: DANVERS MA 01923
Phone: 508-777-1100
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENT 2
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE:EYES:SEVERE IRRITATION OR BURNS, SENSITIZATION OR
ALLERGIC RESPONSE. SKIN:SEVERE IRRITATION OR BURNS. INHALATION:RESPIRATORY
IRRITATION, POSSIBLE SENSITIZATION OR ALLERGIC RESPONSE. INGEST:NO DA TA.
CHRONIC:PROLONGED OR REPEATED EXPOSURE MAY CAUSE ASTHMA AND SKIN
SENSITIZATION OR OTHER ALLERGIC RESPONSE.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: ALLERGY, ASTHMA, ECZEMA.
First Aid: EYES:FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CONTACT A PHYSICIAN.
A ONE PERCENT BORIC ACID RINSE MAY BE USED IF AVAILABLE. SKIN:WASH THOROUGHLY
WITH SOAP AND WATER. INHALATION:REMOVE TO FRESH AIR. I NGESTION:DO NOT INDUCE
VOMITING. GIVE LARGE AMOUNTS OF WATER OR MILK AND TRANSPORT TO A MEDICAL
FACILITY.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: PREVENT SKIN AND EYE CONTACT. REMOVE CONTAMINATED
CLOTHING. DISCARD CONTAMINATED LEATHER ARTICLES SUCH AS SHOES AND BELTS.
ABSORB SPILLAGE ON INERT MATERIAL AND DISCARD IN SUITABLE CONTAINERS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). REMOVE TO A WASTE DISPOSAL FACILITY OPERATING IN
COMPLIANCE WITH STATE AND LOCAL REGULATIONS.
Handling And Storage Precautions: PRLNGD/RPTD OVEREXP MAY CAUSE SENSIT &
ALLERGIC RESPONSE. PERSONS SO AFFECTED SHOULD CONSULT MD. IF SENSIT IS
CONFIRMED, AVOID FURTHER EXPOS TO MATL.
Other Precautions: STORE IN A COOL, DRY PLACE. IF THIS PRODUCT IS SANDED OR
MACHINED AFTER CURING, TAKE APPROPRIATE PRECAUTIONS AGAINST INHALATION OF
NUISANCE PARTICULATES. A TLV-TWA OF 10 MG/M3 SHOULD BE OBSERVED.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: 180F,82C
Extinguishing Media: CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NONE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE NEEDED IN NORMAL USE WITH PROPER VENTILATION. IN
POORLY VENTILATED AREAS, USE NIOSH/MSHA APPROVED ORGANIC VAPOR CARTRIDGE
MASKS.
Ventilation: LOCAL EXHAUST IS RECOMMENDED FOR FOR PROLONGED OR REPEATED USE.
EFFECTIVE MECHANICAL VENT IS ADEQ FOR OCCASIONAL USE.
Protective Gloves: CHEMICAL RESISTANT RUBBER GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS(SUPDAT)
Other Protective Equipment: ANSI APPROVED EMERGENCY EYE WASH AND DELUGE SHOWER
(FP N). OTHER PROTECTIVE CLOTHING AS REQUIRED TO PREVENT SKIN CONT.
Work Hygienic Practices: KEEP HANDS AWAY FROM FACE WHEN HNDLG MATL/BEFORE
WASHING AFTER USE. WASH THORO AFTER USING, PARTICULARLY BEFORE (SUPDAT)
Supplemental Safety and Health: USERS OF THE "L" VERSION SHOULD CONSULT THE
"LR" VERSION FOR ADDITIONAL INFORMATION (FP N). PH (5% BY WEIGHT IN
WATER):10.5. EYE PROT:AND FULL LENGTH FACE SHIELD (FP N). HYGIENE
PRACT:EATING OR SMOKIN G.
=======================================================
Physical/Chemical Properties
=======================================================
Vapor Pres: <1 @ 25F
Vapor Density: >1
Spec Gravity: 1.48
PH: SUPDAT
Solubility in Water: NIL
Appearance and Odor: VISCOUS WHITE PASTE WITH AMMONIA LIKE ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: EXPOSURE TO OPEN FLAME AND EXCESSIVE HEAT.
Materials To Avoid: STRONG OXIDIZING AGENTS, ACIDS AND CHLORINATED ORGANIC
COMPOUNDS.
Hazardous Decomposition Products: OXIDES OF CARBON, NITROGEN AND AMMONIA.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: HEAT IS GENERATED WHEN MIXED WITH EPOXY
HARDENER. USE CAUTION WHEN MIXING LARGE QUANTITIES.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: UNDERWATER REPAIR PUTTY HARDENER, 11800
Assigned IND: Y
Company: ITW DEVCON CORP
Street: 30 ENDICOTT ST
City: DANVERS MA
Zipcode: 01923
Health Emergency Phone: 800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 11/30/1995
Status Code: C
Label Date: 11/30/1995
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Severe
Fire Hazard: Moderate
Reactivity Hazard: None
Hazard And Precautions: AVOID EYE AND SKIN CONTACT. ACUTE:EYES:SEVERE
IRRITATION OR BURNS, SENSITIZATION OR ALLERGIC RESPONSE. SKIN:SEVERE
IRRITATION OR BURNS. INHALATION:RESPIRATORY IRRITATION, POSSIBLE
SENSITIZATION OR ALL ERGIC RESPONSE. CHRONIC:PROLONGED OR REPEATED EXPOSURE
MAY CAUSE ASTHMA AND SKIN SENSITIZATION OR OTHER ALLERGIC RESPONSE.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.