CERTIFIED LABS DIV NCH CORP -- STRATA PLUS, 0540
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBFMP
MSDS NAME: STRATA PLUS, 0540
Responsible Party
Name: CERTIFIED LABS DIV NCH CORP
Box: 152170
City: IRVING TX 75015
Info Phone: 214-438-1381
Emergency Phone Number: 214-438-1381
Preparer's Name: K WOODY
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: CERTIFIED LABS DIV OF NCH CORP
Box: 152170
City: IRVING TX 75015
Phone: 214-438-1381972-438-1381
Name: NCH CORP
Address: 2727 CHEMSEARCH BLVD
Box: 152170
City: IRVING TX 75015-2170
Phone: 972-438-0563
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: SEE INGREDIENTS.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE:MAY CAUSE IRRITATION IF INHALED. MAY BE IRRITATING
TO EYES CAUSING REDNESS. INGESTION MAY RESULT IN NAUSEA. ASPIRATION OF
MATERIAL INTO LUNGS MUST BE AVOIDED. ALTHOUGH PRODUCT HAS LOW ORDER OF O RAL
TOXICITY. EVEN MINUTE AMOUNTS ASPIRATED INTO THE LUNGS DURING INGESTION OR
VOMITING MAY CAUSE MILD(EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: HLTH HAZ:TO SEVERE PULMONARY INJURY &
POSSIBLY DEATH. CHRONIC: MARKED IRRIT OF EYES UPON CHRONIC OVEREXPOSURE.
PRLNG/RPTD CONTACT WITH SKIN TENDS TO REMOVE SKIN OILS POSSIBLY LEADING TO
SKIN IRRITATIO N & DERMATITIS. HOWEVER, DUE TO USE PATTERN OF THE
PRODUCT, THIS IS NOT, IN OUR BEST JUDGMENT TO BE THE PRIMARY HAZARD.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHAL:REMOVE FROM AREA TO FRESH AIR. SEEK MED ATTN IF RESP IRRIT
DEVELOPS/IF BRTHG BECOMES DFCLT. EYE:RINSE EYES W/H*2O. REMOVE ANY CONTACT
LENSES, & CONTINUE FLUSHING W/PLENTY OF H*2O FOR AT LEAST 15 MIN. SEEK
MED ATTN IF IRRIT DEVELOPS/PRESISTS. SKIN:WASH AFFECTED AREAS W/PLENTY OF
H*2O, & SOAP IF AVAIL, FOR SEVERAL MIN. SEEK ATTN IF IRRIT
DEVELOPS/PERSIST. INGEST:GIVE 3 TO 4 GLASSES OF (SUPDAT)
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ELIMINATE ALL SOURCES OF IGNITION. TAKE UP WITH
ABSORBANT MATERIAL AND PLACE IN LABELED CONTAINER FOR DISPOSAL.
Waste Disposal Methods: DISPOSE ON IF ACCORDANCE WITH ALL FEDERAL, STATE, AND
LOCAL REGULATIONS.
Handling And Storage Precautions: STORAGE TEMP:120F MAX 32F MIN INDOOR. "EMPTY"
CNTNRS RETAIN RESIDUE (LIQ/VAP) DO NOT PRESSURIZE, CUT, WELD, SOLDER,
DRILL/EXPOSE SUCH CNTNRS
Other Precautions: KEEP OUT OF REACH OF CHILDREN. READ ENTIRE LABEL BEFORE
USING PRODUCT.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: TCC
Flash Point Text: 315F,157C
Lower Limits: 0.9%
Upper Limits: 7%
Extinguishing Media: FOAM, CO*2, DRY CHEMICAL, WATER SPRAY.
Fire Fighting Procedures: USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP (FP
N). IN CASES WHERE HIGH TEMP/FLAMING OCCUR SUCH AS AN EMERGENCY SITUATIONS,
AS W/ALL PETROLEUM BASED (SUPDAT)
Unusual Fire/Explosion Hazard: BE AWARE THAT PETROLEUM VAPS ARE HEAVIER THAN
AIR & MAY ACCUM IN LOW AREAS/AREAS INADEQUATELY VENT RSLTG IN LOCATIONS
THAT MIGHT BE IGNITABLE AT AREAS (SUPDAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: TYPICAL USE DOES NOT REQUIRE RESPIRATORS, HOWEVER, IN
EMERGENCY SITUATIONS WHERE EXPOSURE EXCEEDS OSHA STANDARDS:IDLH
50000PPM/SAF/SCRAF. AVOID BREATHING MISTED OIL. NIOSH/MSHA APPROVED
RESPIRATOR APP ROPRIATE FOR EXPOSURE OF CONCERN (FP N).
Ventilation: LOCAL VENTILATION.
Protective Gloves: NEOPRENE GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: USERS OF "L" VERSION OF SHOULD CONSULT "LR"
VERSION FOR ATTNL INFO (FP N). FIRE FIGHT PROC: PRODS WHERE APPROP NIOSH/MSHA
APPRVD RESP. EXPLO HAZ: DISTANT TO HNDLG SITE. FIRST AID PROC: WATER BUT DO
NOT INDUCE VOMIT. GET MED ATTN TO DETERM WHETHER EVACUATION OF STOMACH IS
NEC.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: 465F,241C
Vapor Pres: 0.01
Vapor Density: 5
Spec Gravity: 0.89 (H*2O=1)
PH: 100
Evaporation Rate & Reference: 0.01 (BU AC = 1)
Solubility in Water: NEGLIGIBLE
Appearance and Odor: AMBER; PETROLEUM ODOR; OPAQUE.
Percent Volatiles by Volume: 1
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Materials To Avoid: OPEN FLAME AND STONG OXIDIZING AGENTS LIKE LIQUID CHLORINE,
LIQUID OXYGEN, AND SODIUM AND CALCIUM HYPOCHLORITIES.
Hazardous Decomposition Products: FUMES, SMOKE, OXIDES OF CARBON AND SULFUR,
ALDEHYDES AND OTHER DECOMPOSITION PRODUCTS OF INCOMPLETE COMBUSTION.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: STRATA PLUS, 0540
Company: NCH CORP
Street: 2727 CHEMSEARCH BLVD
PO Box: 152170
City: IRVING TX
Zipcode: 75015-2170
Health Emergency Phone: 214-438-1381
Label Required IND: Y
Date Of Label Review: 01/17/1996
Status Code: C
Label Date: 01/17/1996
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Moderate
Fire Hazard: Slight
Reactivity Hazard: Slight
Hazard And Precautions: COMBUSTIBLE. DECOMPOSITION PRODUCTS MAY BE HAZARDOUS.
ACUTE:MAY CAUSE IRRIT IF INHALED. MAY BE IRRIT TO EYES CAUSING REDNESS.
INGEST MAY RESULT IN NAUSEA. ASPIRATION OF MATERIAL INTO LUNGS MUST BE AVO
IDED. ALTHOUGH PRODUCT HAS LOW ORDER OFORAL TOX EVEN MINUTE AMOUNTS ASPIRATED
INTO THE LUNGS DURING INGEST OR VOMIT MAY CAUSE MILD TO SEVERE PULMONARY
INJURY & POSSIBLE DEATH. CHRONIC:MARKED IRRIT OF EYES UPON CHRONIC
OVEREXPOSURE. PROLONGED OR REPEATED CONTACT WITH SKIN TENDS TO REMOVE SKIN
OILS POSSIBLY LEADING TO SKIN IRRIT & DERMATITIS. HOWEVER, DUE TO USE
PATTERN OF THE PRODUCT, THIS IS NOT, IN OUR BEST JUDGEMENT TO BE THE PRIMARY
HAZARD.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|