CHEVRON -- SYNTHETIC GEAR LUBRICANT TEGRA ISO 460, CPS23
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CBKJT
MSDS NAME: SYNTHETIC GEAR LUBRICANT TEGRA ISO 460, CPS233916
Responsible Party
Name: CHEVRON
Address: 575 MARKET ST ROOM 2900
City: SAN FRANCISCO CA 94105-2856
Info Phone: 800-582-3835
Emergency Phone Number: 800-231-0623;800-424-9300(CHEMTREC)
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: CHEVRON CHEMICAL CO CONSUMER PRODUCTS DIV
Address: 575 MARKET ST
Box: 3744
City: SAN FRANCISCO CA 94105-2823
Phone: 800-822-5823
Name: CHEVRON ENVIRONMENTAL HEALTH CENTER INC
Address: 15299 SAN PABLO AVE
Box: 4054
City: RICHMOND CA 94804
Phone: 800-582-3835
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYES & SKIN:SUBSTANCE IS NOT EXPECTED TO CAUSE
PRLNGD/SIGNIFICANT IRRIT. HAZ EVAL IS BASED ON KNOWN TOX OF INGS IN
SUBSTANCE. SKIN HAZ EVAL IS BASED ON DATA FROM SIMILAR MATLS. SYSTEMIC TOX OF
SUBSTAN CE HAS NOT BEEN DETERM. HOWEVER, IT SHOULD BE PRACTICALLY NON-TOX TO
INTERNAL ORGANS IF IT GETS ON (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZS:SKIN. INGEST &
INHAL:SYSTEMIC TOX OF SUBSTANCE HAS NOT BEEN DETERM. HOWEVER, IT SHOULD BE
PRACTICALLY NON-TOX TO INTERNAL ORGANS. HAZ EVAL IS BASED ON DATA FROM
SIMILAR MATLS. TOX INFO:EYE, INHAL:NO PROD TOX DATA AVAIL. HAZ EVAL WAS
BASED ON DATA ON COMPONENTS. SKIN, INGEST:NO PROD TOX DATA AVAIL. HAZ(SUPDAT)
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INGESTION:CALL MD IMMEDIATELY (FP N). INHALATION:REMOVE TO FRESH
AIR. SUPPORT BREATHING (GIVE O*2/ARTF RESP) (FP N). EYES:NO FIRST AID PROC
ARE REQUIRED. HOWEVER, AS PRECAUTION FLUSH WITH FRESH WATER FOR AT LEAST 15
MINUTES. REMOVE CONTACTLENSES IF WORN. SKIN:NO FIRST AID PROC ARE REQUIRED.
AS A PRECAUTION, WASH THOROUGHLY WITH SOAP AND WATER. REMOVE AND WASH
CONTAMINATED CLOTHING.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CHEMTREX EMERGENCY NUMBER (24 HR):800-424-9300 OR
202-483-7616. CLEAN UP SPILLS IMMEDIATELY, OBSERVING PRECAUTIONS IN CONTROL
MEASURES DATA.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE I/A/W FEDERAL, STATE & LOCAL
REGULATIONS (FP N). PLACE CONTAMINATED MATERIALS IN DISPOSABLE CONTAINERS AND
DISPOSE OF IN A MANNER CONSISTENT WITH APPLICABLE REGULATIONS. CONTACT LOCAL
ENVIRON/HLTH AUTHS FOR APPRVD DISP OF MATL.
Handling And Storage Precautions: DO NOT WELD, HEAT OR DRILL CONTAINER. RESIDUE
MAY IGNITE WITH EXPLOSIVE VIOLENCE IF HEATED SUFFICIENTLY.
Other Precautions: CAUTION! DO NOT USE PRESSURE TO EMTPY DRUM OR DRUM MAY
RUPTURE WITH EXPLOSIVE FORCE. AVOID PROLONGED OR FREQUENTLY REPEATED SKIN
CONTACT WITH THIS MATERIAL.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: COC
Flash Point Text: 410F,210C
Extinguishing Media: CO*2, DRY CHEMICAL, FOAM AND WATER FOG.
Fire Fighting Procedures: WEAR NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: NORMAL COMBUSTION FORMS CARBON DIOXIDE, WATER
VAPOR AND MAY PRODUCE OXIDES OF SULFUR, NITROGEN AND PHOSPHORUS. INCOMPLETE
COMBUSTION CAN PRDCE CARBON MONOXIDE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: USE NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN (FP N). NO SPECIAL RESPIRATORY PROTECTION IS NORMALLY
REQUIRED.
Ventilation: NO SPECIAL VENT IS USUALLY NEC. HOWEVER, IF OPERATING CNDTNS
CREATE HIGH AIRBORNE CONCS OF MATL, SECIAL VENT
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: ANSI APPROVED EMERGENCY EYE WASH AND DELUGE SHOWER
(FP N). SKIN CONTACT CAN BE MINIMIZED BY WEARING PROTECTIVE CLOTHING.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: USERS OF "L" VERSION CONSULT "LR" VERSION FOR
ADDNL INFO (FP N). SPEC GRAV:0.87 @ 15.6/15.6C. EFTS OF OVEREXP:EVAL WAS
BASED ON DATA FROM SIMILAR MATLS. ADDNL TOX INFO:PROD CNTNS SYNTHETIC BASE
OILS N OT REFINED FROM PETROL BASE STOCKS. POTNTL OF BASE OIL PREPARED BY
THIS PROCESS TO CAUSE CANCER HAS NOT BEEN
=======================================================
Physical/Chemical Properties
=======================================================
Spec Gravity: SUPP DATA
Solubility in Water: INSOLUBLE
Appearance and Odor: HEAVY DARK COLORED OIL.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NO DATA AVAILABLE.
Materials To Avoid: MAY REACT WITH STRONG OXIDIZING AGENTS, SUCH AS CHLORATES,
NITRATES, PEROXIDES, ETC.
Hazardous Decomposition Products: NO DATA AVAILABLE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: SYNTHETIC GEAR LUBRICANT TEGRA ISO 460, CPS233916
Company: CHEVRON ENVIRONMENTAL HEALTH CENTER INC
Street: 15299 SAN PABLO AVE
PO Box: 4054
City: RICHMOND CA
Zipcode: 94804
Health Emergency Phone: 800-231-0623;800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 02/22/1996
Status Code: C
Label Date: 02/22/1996
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE:EYES AND SKIN:SUBSTANCE IS NOT EXPECTED TO CAUSE
PROLONGED OR SIGNIFICANT IRRITATION. THE SYSTEMIC TOXICITY OF SUBSTANCE HAS
NOT BEEN DETERMINED. HOWEVER, IT SHOULD BE PRACTICALLY NON-TOXIC TO I NTERNAL
ORGANS IF IT GETS ON SKIN. CHRONIC:NONE SPECIFIED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.