HACH CO -- 1055 SULFAMIC ACID REAGENT
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CCZMG
MSDS NAME: 1055 SULFAMIC ACID REAGENT
Responsible Party
Name: HACH CO
Address: 5600 LINDBERGH DR
Box: 389
City: LOVELAND CO 80539-0389
Info Phone: 303-962-6721/515-232-2533
Emergency Phone Number: 303-962-6721/515-232-2533
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: HACH COMPANY
Address: 100 DAYTON RD.
Box: 907
City: AMES IA 50010
=======================================================
Contractor Summary
=======================================================
Name: HACH CO
Address: 5600 LINDBERGH DR
Box: 389
City: LOVELAND CO 80539
Phone: 970-669-3050/ 303-623-5716
Name: HACH COMPANY
Address: 100 DAYTON RD.
Box: 907
City: AMES IA 50010
Phone: 800-227-4224
=======================================================
Ingredients
=======================================================
Cas: 5329-14-6
RTECS #: WO5950000
Name: SULFAMIC ACID
% Wt: <100
------------------------------
Name: OTHER COMPONENTS
% Wt: <1
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ORAL LD50(RAT): 3160 MG/KG
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: MODERATELY TOXIC. OVEREXPOSURE MAY CAUSE IRRITATION OF THE
SKIN, RESPIRATORY TRACT, MOUTH, ESOPHAGUS & GI TRACT.
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: IRRITATION
Medical Cond Aggravated By Exposure: PRE-EXISTING EYE, SKIN & RESPIRATORY
TRACT DISORDERS.
First Aid: EYES/SKIN: FLUSH W/WATER FOR 15 MINS. INGESTION: DON'T INDUCE
VOMITING. GIVE 1-2 GLASSES OF WATER. NEVER GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON. INHALATION: REMOVE TO FRESH AIR. OBTAIN MEDICA L
ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: COVER W/SODA ASH/SODIUM BICARBONATE. MIX & ADD
WATER IF NECESSARY. USE LITMUS PAPER, MAKE SURE PH OF SLURRY IS NEUTRAL/ADD
NEUTRALIZER UNTIL MIXTURE STOP BUBBLING. SCOOP UP THE SLURRY & WASH THE
NEUTR AL WASTE DOWN THE DRAIN W/EXCESS WATER.(SUPP)
Waste Disposal Methods: DISPOSE OF IAW/FEDERAL, STATE & LOCAL REGULATIONS.
UN2967.
Handling And Storage Precautions: STORE TIGHTLY CLOSED IN A DRY PLACE. KEEP
AWAY FROM HEAT, SPARKS & OPEN FLAMES.
Other Precautions: AVOID CONTACT W/EYES, SKIN & CLOTHING. DON'T BREATHE
DUST.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: WATER/DRY CHEMICAL
Unusual Fire/Explosion Hazard: MAY REACT VIOLENTLY W/CHLORINE/FUMING NITRIC
ACID, METAL NITRATES, METAL NITRITES. MAY EMIT TOXIC FUMES OF SULFUR
OXIDES/NITROGEN OXIDES & AMMONIA IN FIRE.
=======================================================
Control Measures
=======================================================
Ventilation: ADEQUATE VENTILATION
Protective Gloves: RUBBER
Eye Protection: LAB GRADE GOGGLES
Other Protective Equipment: LAB COAT
Work Hygienic Practices: WASH THOROUGHLY AFTER HANDLING. REMOVE/LAUNDER
CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health: PH IS OF 1% SOLUTION. SPILLS CONT'D: WASH SITE
W/SODA ASH SOLUTION.
=======================================================
Physical/Chemical Properties
=======================================================
M.P/F.P Text: 401F
Spec Gravity: 2.15
PH: 1.1
Appearance and Odor: WHITE CRYSTALLINE SOLID POWDER W/NO ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: HEAT, MOISTURE, SPARKS, OPEN FLAMES.
Materials To Avoid: CHLORINE, FUMING NITRIC ACID, METAL NITRATES, METAL
NITRITES, OXIDIZERS, BASES.
Hazardous Decomposition Products: FIRE: TOXIC FUMES OF SULFUR OXIDES/NITROGEN
OXIDES & AMMONIA.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: 1055 SULFAMIC ACID REAGENT
Company: HACH COMPANY
Street: 100 DAYTON RD.
PO Box: 907
City: AMES IA
Zipcode: 50010
Health Emergency Phone: 303-962-6721/515-232-2533
Label Required IND: Y
Date Of Label Review: 10/12/1999
Status Code: A
Origination Code: G
Hazard And Precautions: MODERATELY TOXIC. OVEREXPOSURE MAY CAUSE IRRITATION OF
THE SKIN, RESPIRATORY TRACT, MOUTH, ESOPHAGUS & GI TRACT.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|