M A BRUDER & SONS INC -- PLY-THANE 890, 020069 (I)
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CDMGT
MSDS NAME: PLY-THANE 890, 020069 (I)
Responsible Party
Name: M A BRUDER & SONS INC
Address: 600 REED RD
City: BROOMALL PA 19008
Info Phone: 215-359-3635
Emergency Phone Number: 215-353-5100
Proprietary Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: M A BRUDER & SONS INC
Address: 600 REED RD
Box: 600
City: BROOMALL PA 19008
Phone: 610-353-5100;610-359-3635
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHAL:IRRIT OF RESP TRACT. PRLNG INHAL MAY LEAD TO FATG,
DROW, DIZZ &/OR LT HEAD, HDCH, LACK OF COORD, NAUS, VOMIT, CNS DEPRESS,
ANESTH EFT/NARCOS. SKIN CONT:IRRIT. PRLNG/RPTD CONT CAN CAUSE DERM, DEF AT.
EYE CONT:IRRIT. PRLNG/RPTD CONT CANCAUSE BLURRED VISION, REDNESS, TEARING,
SEV IRRIT. INGEST:AMTS (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ:INGESTED INCIDENTAL TO CONSUMER
& INDUS HNDLG ARE NOT LIKELY TO CAUSE INJURY; HOWEVER, LGR AMTS MAY CAUSE
LUNG INFLAMM & DMG DUE TO ASPIR OF MATL INTO LUNGS. NOTICE:RPTS HAVE
ASSOC RPTD & PRL NG OCCUP OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS
DMG. INTENTIONAL MISUSE BY DELIB CONC & INHAL CONTENTS MAY BE
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INHAL:REMOVE TO FRESH AIR. RESTORE & SUPPORT CONTINUED
BREATHING. HAVE TRAINED PERSON GIVE OXYGEN IF NECESSARY. GET EMERGENCY
MEDICAL ATTENTION. SKIN:WASH OFF QUICKLY W/PLENTY OF WATER, THEN SOAP &
WA TER; REMOVE & WASH CONTAMINATED CLOTHING BEFORE REUSE. EYES:FLUSH
IMMEDIATELY W/LARGE AMTS OF WATER, ESP UNDER LIDS, FOR AT LST 15 MINS. OBTAIN
EMER MED TREATMENT. INGEST:OBTAIN MED TREATMENT IMMED.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: REMOVE ALL SOURCES OF IGNITION (FLAME, HOT SURFACES
& ELECTRICAL, STATIC SPARKS). VENTILATE AREA & AVOID BREATHING
VAPORS. CONTAIN & REMOVE W/INERT ABSORBENT MATERIAL USING NON-SPARKING
TOOLS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE I/A/W LOCAL, STATE & FEDERAL REGULATIONS.
AVOID DISCHARGE TO NATURAL WATERS.
Handling And Storage Precautions: DO NOT STORE IN SUN/>100F. STORE LG QTYS
IN BLDGS DESIGNED FOR STOR OF FLAMM/COMBUST LIQS. DO NOT TAKE INTERNALLY.
KEEP OUT OF REACH OF CHILDREN.
Other Precautions: DO NOT WELD/FLAME CUT W/OUT PROPER VENT TO INSURE AREA IS
FREE OF FLAMM VAPS. DO NOT CUT, PUNCTURE/WELD ON/NEAR CNTNR. ENTRANCE INTO
CLSD STOR TANKS - USE APPROP NIOSH APPRVD RESP/AIRLINE FOR POSS EXP OS TO
SOLV/CHEM FUMES. RAGS/ (SUPDAT)
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: SCC
Flash Point Text: 60.0F,15.6C
Extinguishing Media: DRY CHEMICAL OR FOAM.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N). WATER MAY BE USED TO COOL & PROTECT EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard: FLAMM LIQ-CLASS IB. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT/FIRE. VAPS CAN FORM EXPLO MIXTS IN AIR AT ELEVATED
TEMPS. MAY DECOMP UNDER FIRE (SUPDAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: CONTROL ENVIRON CONCS BELOW APPLIC STDS. NIOSH APPRVD
PROPERLY FITTED AIR PURIFYING/SUPPLIED AIR RESP PROVEN TO BE EFTIVE IN
PARTICULATE, ORG VAP & ISOCYANATE CNTNG SPRAY PAINT ENVIRONS MAY BE NEC.
OB SERVE OSHA REGS FOR RESP USE 29 (SUPDAT)
Ventilation: ALL APPLICATION AREAS SHOULD BE VENTILATED I/A/W OSHA REGULATION
29 CFR 1910 DURING USE & UNTIL AREA IS FREE OF VAPORS.
Protective Gloves: IMPERVIOUS GLOVES.
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NOTE:USERS OF "L" VERSION SHOULD CONSULT "LR"
VERSION FOR ADDNL INFO (FP N). EXPLO HAZ:CNDTNS EMITTING IRRIT &/OR TOX
GASES. RESP PROT:CFR 1910.134. OTHER PREC:WASTE CNTNG OIL BASED PAINT/VARNISH
THAT PRESENT LG AIR-TO-OIL INTERFACE WILL OXIDIZE & MAY IGNITE SPONT
& SHOULD BE PLACE IN METAL CNTNR.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >241F,>116C
Vapor Pres: SEE INGS
Spec Gravity: 1.01-1.29(FP N)
Evaporation Rate & Reference: SLOWER THAN ETHYL ETHER
Appearance and Odor: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: ELEVATED TEMPERATURES. CONTACT W/OXIDIZING
AGENTS.
Materials To Avoid: OXIDIZERS, ACIDS, BASES, AMINES.
Hazardous Decomposition Products: CARBON MONOXIDE, CARBON DIOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PLY-THANE 890, 020069 (I)
Company: M A BRUDER & SONS INC
Street: 600 REED RD
PO Box: 600
City: BROOMALL PA
Zipcode: 19008
Health Emergency Phone: 215-353-5100
Label Required IND: Y
Date Of Label Review: 04/03/1997
Status Code: C
Label Date: 04/03/1997
Origination Code: G
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Moderate
Contact Hazard: Slight
Fire Hazard: Severe
Reactivity Hazard: None
Hazard And Precautions: EXTREMELY FLAMM. ACUTE:INHAL:IRRIT OF RESP TRACT. PRLNG
INHAL MAY LEAD TO FATG, DROW, DIZZ &/OR LT HEAD, HDCH, LACK OF COORD,
NAUS, VOMIT, CNS DEPRESS, ANESTH EFT/NARCOS. SKIN:IRRIT. PRLNG/RPTD CONT C AN
CAUSE DERM, DEFAT. EYE:IRRIT. PRLNG/RPTD CONT CAN CAUSE BLURRED VISION,
REDNESS, TEARING, SEV IRRIT. INGEST:LG AMTS MAY CAUSE LUNG INFLAMM & DMG
DUE TO ASPIR INTO LUNGS. CHRONIC:RPTS HAVE ASSOC RPT D & PRLNG OCCUP
OVEREXP TO SOLVS W/PERM BRAIN & NERV SYS DMG. INTENTIONAL MISUSE BY DELIB
CONC & INHAL CONTENTS MAY BE HARMFUL/FATAL. FREE ISOCYANATES MAY CAUSE
ALLERGIC SKIN/RESP RXN IN SUSCEPTIBLE P ERS. RESP SENSIT MAY RSLT IN
ASTHMA-LIKE SYMPS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.
*** END OF RECORD *** |
|
|