CANON U.S.A., INC. -- F41-6921, CLC 500 TONER (MAGENTA)
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 01-318-3904
MSDS Num: CDMNN
MSDS NAME: F41-6921, CLC 500 TONER (MAGENTA)
Responsible Party
Name: CANON U.S.A., INC.
Address: ONE CANON PLAZA
City: LAKE SUCCESS NY 11042
Info Phone: 516-488-6700
Emergency Phone Number: 516-488-6700/800-424-9300(CHEMTREC)
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: AUTOMATION AIDS INC (800-234-2790)
Address: 420 BABYLON RD, SUITE B
Box: UNKNOW
City: HORSHAM PA 19044
Phone: 800-817-4448
Name: CANON USA INC
Address: ONE CANON PLZ
City: NEW HYDE PARK NY 11042
Phone: 516-328-5000; 5600
=======================================================
Item Description Information
=======================================================
Item Manager: S9G
Item Name: TONER,INDIRECT ELECTROSTATIC PROCESSING
Unit of Issue: EA
UI Container Qty: 0
Type of Container: PREMIXED UNIT
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: PRODUCT'S LD50 (ORAL RAT) WAS NOT STATED
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE-EYE:NO SPECIFIC HAZARD KNOWN TO CANON. HOWEVER, ANY
MATERIAL CONTACTING THE EYE MAY BE IRRITATING. SKIN:LOW HAZARD FOR INDUSTRIAL
HANDLING. INHALATION:TONER IS FINELY DIVIDED SOLID. DO NOT BREAT HE DUST. NO
DATA AVAILABLE ON CHRONIC EFFECTS OF OVEREXPOSURE.
Explanation Of Carcinogenicity: MFR GAVE THE ABOVE LISTINGS ON THE MSDS BUT NO
OTHER COMMENTS ABOUT CARCINOGENICITY WERE RECORDED.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: MFR GAVE NO INFORMATION OF MSDS.
First Aid: INHALATION:REMOVE FROM EXPOSURE TO FRESH AIR. EYES:OPEN EYE &
FLUSH W/PLENTY OF WATER FOR A MINIMUM OF 15 MINUTES. IF IRRITATION PERSISTS,
GET MEDICAL ATTENTION. SKIN:WASH W/SOAP & WATER. INGESTION:DR INK SEVERAL
GLASSES OF WATER. CALL A PHYSICIAN.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SWEEP MATERIAL ONTO PAPER & PLACE IN FIBER
CARTON.
Neutralizing Agent: MFR GAVE NO INFORMATION OF MSDS.
Waste Disposal Methods: NO SPECIAL DISPOSAL TECHNIQUE REQUIRED. ENSURE
COMPLIANCE W/FEDERAL, STATE & LOCAL REGULATIONS.
Handling And Storage Precautions: KEEP OUT OF REACH OF CHILDREN. KEEP FROM
CONTACT WITH OXIDIZNG MATERIALS.
Other Precautions: NONE
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: N/A.
Autoignition Temp Text: N/A.
Lower Limits: N/A.
Upper Limits: N/A.
Extinguishing Media: WATER, DRY CHEMICAL, CARBON DIOXIDE.
Fire Fighting Procedures: NON-FLAMMBLE SOLID (ACCORDING TO TEST METHOD OF 16
CFR 1500.44).
Unusual Fire/Explosion Hazard: THIS MATERIAL, LIKE MOST ORGANIC MATERIALS IN
POWDER FORM, IS CAPABLE OF CREATING A DUST EXPLOSION.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NONE REQUIRED.
Ventilation: GOOD GENERAL VENTILATION SHOULD BE SUFFICIENT.
Protective Gloves: NONE REQUIRED.
Eye Protection: NONE REQUIRED.
Other Protective Equipment: NONE.
Work Hygienic Practices: MFR GAVE NO INFORMATION OF MSDS.
Supplemental Safety and Health: NONE
=======================================================
Physical/Chemical Properties
=======================================================
HCC: N1
NRC/State LIC No: NONE
M.P/F.P Text: 212F,100C
Decomp Text: UNKNOWN
Vapor Pres: NEGLIGIBLE
Spec Gravity: 1-1.2
Viscosity: UNKNOWN
Evaporation Rate & Reference: NEGLIGIBLE
Solubility in Water: NEGLIGIBLE
Appearance and Odor: FINE POWDER, SLIGHT PLASTIC ODOR.
Percent Volatiles by Volume: NEGLIG
Corrosion Rate: UNKNOWN
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: MFR GAVE NO INFORMATION OF MSDS.
Materials To Avoid: STRONG OXIDIZERS.
Hazardous Decomposition Products: AS WITH ANY OTHER ORGANIC MATERIAL,
DECOMPOSITION WILL PRODUCE CARBON MONOXIDE, CARBON DIOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: WILL NOT OCCUR.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
Transportation Information
=======================================================
Trans ID NO: 124984
MSDS NAME: F41-6921, CLC 500 TONER (MAGENTA)
MSDS Prepared Date: 05/31/1991
Review Date: 05/03/1997
Tech Entry NOS Shipping Nm: NONE
Net Unit Weight: 2.5 POUNDS
Multiple KIT Number: 0
Review IND: Y
Unit Of Issue: EA
Container QTY: 0
Type Of Container: PREMIXED UNIT
Additional Data: NONE
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: F41-6921, CLC 500 TONER (MAGENTA)
Company: CANON USA INC
Street: ONE CANON PLZ
City: NEW HYDE PARK NY
Zipcode: 11042
Health Emergency Phone: 516-488-6700/800-424-9300(CHEMTREC)
Label Required IND: Y
Date Of Label Review: 05/03/1997
Status Code: C
MFG Label NO: NONE
Label Date: 05/03/1997
Year Procured: 1997
Origination Code: F
Signal Word: CAUTION
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE-EYE:NO SPECIFIC HAZARD KNOWN TO CANON. HOWEVER,
ANY MATERIAL CONTACTING THE EYE MAY BE IRRITATING. SKIN:LOW HAZARD FOR
INDUSTRIAL HANDLING. INHALATION:TONER IS FINELY DIVIDED SOLID. DO NOT BREAT
HE DUST. NO DATA AVAILABLE ON CHRONIC EFFECTS OF OVEREXPOSURE. KEEP OUT OF
REACH OF CHILDREN. KEEP FROM CONTACT WITH OXIDIZNG MATERIALS.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.