Search   
MSDS  : FILTRA PURE 120, SK-0198
CAS  : 7681-52-9
1310-58-3
NAME  : hypochlorous acid, sodium salt; (sodium hypochlorite) (cercla)
potassium hydroxide (cercla)
supdat: sewer authority for recom neutralization procs. do not discharge
ing 3: assistance, consult hb fuller environmental services at
eye prot: & full length faceshield (fp n).
HB FULLER CO -- FILTRA PURE 120, SK-0198
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGVKN
MSDS NAME: FILTRA PURE 120, SK-0198
Responsible Party
Name: HB FULLER CO
Address: 3900 JACKSON ST NE
City: MINNEAPOLIS MN 55421
Info Phone: 612-781-8071
Emergency Phone Number: 800-228-5635
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: HB FULLER CO
Address: 1200 WOLTERS BLVD
City: VADNAIS HEIGHTS MN 55110
Phone: 612-481-3300
=======================================================
Ingredients
=======================================================
Cas: 7681-52-9
RTECS #: NH3486300
Name: HYPOCHLOROUS ACID, SODIUM SALT; (SODIUM HYPOCHLORITE) (CERCLA)
% Wt: 1-10
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
EPA Rpt Qty: 100 LBS
DOT Rpt Qty: 100 LBS
------------------------------
Cas: 1310-58-3
RTECS #: TT2100000
Name: POTASSIUM HYDROXIDE (CERCLA)
% Wt: >10
OSHA PEL: 2 MG/M3, C
ACGIH TLV: 2 MG/M3, C
EPA Rpt Qty: 1000 LBS
DOT Rpt Qty: 1000 LBS
------------------------------
Name: SUPDAT: SEWER AUTHORITY FOR RECOM NEUTRALIZATION PROCS. DO NOT DISCHARGE
TO STORM SEWERS. FOR ADDNL WASTE DISP
-----------------------------
Name: ING 3: ASSISTANCE, CONSULT HB FULLER ENVIRONMENTAL SERVICES AT
612-481-1588.
-----------------------------
Name: EYE PROT: & FULL LENGTH FACESHIELD (FP N).
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: EYES: DIRECT EYE CONTACT WILL CAUSE BURNS AND MAY CAUSE
PERMANENT DAMAGE, EVEN BLINDNESS. SKIN: SKIN CONTACT WITH PRODUCT WILL CAUSE
IRRITATION AND BURNS. INHALATION: MISTS OR SPRAYS WILL IRRITATE AND MAY
DAMAGE UPPER RESPIRATORY TRACT ANDLUNGS. CHRONIC: NO ANTICIPATED CHRONIC
EFFECTS. THIS PRODUCT (EFTS OF OVEREXP)
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: HLTH HAZ: DOES NOT CONTAIN REGULATED
LEVELS OF NTP, IARC OR OSHA LISTED CARCINOGENS.
Medical Cond Aggravated By Exposure: NO KNOWN EFFECTS ON OTHER ILLNESSES.
First Aid: EYES: FLUSH IMMED W/LARGE AMOUNTS OF WATER FOR AT LEAST 15 MINUTES.
CALL MD. SKIN: WASH AFFECTED AREA W/SOAP & WATER. LAUNDER CONTAMINATED
CLOTHING BEFORE REUSE. INHAL: REMOVE FROM EXPOSURE. RESTORE B RTHG IF
NECESSARY. KEEP WARM & QUIET. CALL MD. INGEST: IF PERSON CAN SWALLOW,
GIVE ONE GLASS OF WATER/MILK. DO NOT INDUCE VOMIT. GET IMMED MED ATTN. NEVER
GIVE ANYTHING BY MOUTH TO AN UNCON PERSON.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: CONTAIN SPILL, DILUTE IF NECESSARY AND REMOVE WITH
INERT ABSORBENT.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: THIS PROD, AS PROVIDED, MEETS DEFINITION OF HAZ WASTE
UNDER US EPA HAZ WASTE REGS 40 CFR 261. IT IS HAZ WASTE CLASS D003 - CORR. IT
DOES NOT CONTAIN ANY ADDED RAW MATLS W/KNOWN LEVELS OF TCLP CONSTITU ENTS AS
IDENTIFIED IN SECTION 261.24 OF(SUPDAT)
Handling And Storage Precautions: DO NOT STORE NEAR ACIDS. CONTACT WITH AMMONIA
MAY FORM EXPLOSIVE MIXTURES.
Other Precautions: AVOID SKIN CONTACT WITH PRODUCT. WEAR APPROPRIATE PROTECTIVE
EQUIPMENT WHEN WORKING WITH THIS PRODUCT.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: NON-FLAMMABLE
Extinguishing Media: LIQUID MATERIAL - NONFLAMMABLE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N). NON-FLAMMABLE.
Unusual Fire/Explosion Hazard: THERE IS THE POSSIBILITY OF PRESSURE BUILDUP IN
CLOSED CNTNRS WHEN HEATED. CONTACT W/SOME METALS, PARTICULARLY MAGNESIUM,
ALUMINUM & ZINC (GALVANIZED (SUPDAT)
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT NORMALLY REQUIRED. USE NIOSH APPROVED PARTICULATE
RESPIRATOR IF PRODUCT IS BEING SPRAYED.
Ventilation: STANDARD INDUSTRIAL VENTILATION.
Protective Gloves: RUBBER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGS
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N).
PREVENT CONTACT BY USING APPROPRIATE PROTECTIVE CLOTHING.
Work Hygienic Practices: LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health: PH: 12 (1% SOLUTION). EXPLO HAZ: METAL) CAN
RAPIDLY LIBERATE HYDROGEN GAS, WHICH IS EXPLOSIVE. WASTE DISP METH: U.S. EPA
HAZ WASTE REGS. LEACHATE TESTS HAVE NOT BEEN PERFORMED. STATE & LOCAL HAZ
WASTE REGS MAY APPLY IF THEY DIFFER FROM FEDREG. DO NOT NEUTRALIZE W/DILUTE
ACID. CONSULT YOUR LOCAL SANITARY
=======================================================
Physical/Chemical Properties
=======================================================
Spec Gravity: 1.26 (FP N)
PH: SUPDAT
Appearance and Odor: AMBER LIQUID.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: STRONG ACIDS, AMMONIA SOLUTIONS.
Hazardous Decomposition Products: CHLORINE GAS MAY EVOLVE DURING A FIRE OR IF
PRODUCT IS MIXED WITH ACID LIQUIDS.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: FILTRA PURE 120, SK-0198
Assigned IND: Y
Company: HB FULLER CO
Street: 1200 WOLTERS BLVD
City: VADNAIS HEIGHTS MN
Zipcode: 55110
Health Emergency Phone: 800-228-5635
Label Required IND: Y
Date Of Label Review: 04/16/1998
Status Code: C
Label Date: 04/16/1998
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: DANGER
Respiratory Protection IND: YES
Health Hazard: Severe
Contact Hazard: Severe
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: CAUSTIC. ACUTE: EYES: DIRECT EYE CONTACT WILL CAUSE
BURNS AND MAY CAUSE PERMANENT DAMAGE, EVEN BLINDNESS. SKIN: SKIN CONTACT WITH
PRODUCT WILL CAUSE IRRITATION AND BURNS. INHALATION: MISTS OR SPRAYS W ILL
IRRITATE AND MAY DAMAGE UPPER RESPIRATORY TRACT AND LUNGS. CHRONIC: NONE
LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
BOUNCE, SCENTED HOUSEHOLD FABRIC SOFTENER (SUPDAT) 1318-02-1
ETHANOL SPEC IND ANHY 4082, 7030400 64-17-5
67-63-0
67-56-1
ETHYL ALCOHOL 64-17-5
PHENYLBENZOATE, MDW158 93-99-2
DPD REAGENT 2, R-0002
SAVIN 3640 TONER, 9841
G5652, ANTI-MOUSE IGM (MU-CHAIN SPECIFIC)- (SUP DAT)
INNERBOND E-6 EMULSION
CHAFE SAFE, 990
EPOXY MORTAR & GROUT, TA-0470-A 927 112945-52-5
070072, CB-10 LIQUID NAILS FOR COVE BASE (SUPDAT)
C22N
NADEP-101 110-12-3
108-65-6
763-69-9
SICOMET FSTC ACCEL 123-31-9
76-13-1
67-64-1
GLANCER CUSHION REPAIR ADHESIVE, 171502 78-93-3
DEGREASE-IT, CW 2295
AWL-BRITE PLUS CONVERTER, J3006 763-69-9
822-06-0
ENERPAC HF HYDRAULIC OIL
ENERPAC HOP HYDRAULIC OIL
SCOTCHLITE GLASS BUBBLES TYPE A 65997-17-3
111031-82-4
SCOTCHLITE GLASS BUBBLES TYPE D 65997-17-3
111031-82-4
HS III 10:1 COLORED CATALYST 682-01-9
77-58-7
2996-92-1
67-63-0
67-56-1
63148-62-9
PRO-SEAL 890 B-2 PART B 108-88-3
9039-25-2
13463-67-7
1317-65-3
68611-50-7
67762-90-7
CITRIC ACID, ANHYDROUS 77-92-9
5949-29-1
7440-38-2
1309-37-1
SM-8400, SICOMET 8400
FILTRA PURE 120, SK-0198 7681-52-9
1310-58-3
COOL-FLUSH, 4295
COOL-PLUS, 4297
TIN STANDARD AT 1000 UG/ML, ICP-050 7732-18-5
7697-37-2
7664-39-3
7440-31-5
TCLP ANALYTES MIXTURE, ICM-641 7732-18-5
7697-37-2
7440-38-2
7440-39-3
7440-43-9
7440-47-3
7439-92-1
7782-49-2
7440-22-4
ICM-642, TCLP MERCURY STANDARD, MERCURY (SUP DAT) 7732-18-5
7697-37-2
7439-97-6
CHEMSEARCH 8000, F011
SMALL SCREW THREADLOCKER 222MS, 22231 25852-47-5
9004-96-0
81-07-2
80-15-9
57-55-6
112945-52-5
613-48-9
13463-67-7
SOLIMIDE TA-301 POLYMIDE FOAM
PHILLYBOND BLUE 6A HARDENER
FORM-A-THREAD STRIPPED THREAD REPAIR, (SUPDAT) 24448-20-2
65997-17-3
7429-90-5
79-10-7
2455-24-5
7631-86-9
114-83-0
80-15-9
128-37-0
FORM-A-THREAD STRIPPED THREAD REPAIR, (SUPDAT) 64742-89-8
1330-20-7
75-28-5
74-98-6
67-64-1
64742-47-8
116-14-3
FORM-A-THREAD STRIPPED THREAD REPAIR, (SUPDAT) 24448-20-2
65997-17-3
7429-90-5
2455-24-5
7631-86-9
1338-02-9
HYSOL EE4143
FREKOTE 700-NC, FK0790
ANAEROBIC, 7841 25852-47-5
18268-70-7
80-15-9
102-82-9
HYDRAULIC CEMENT TYPES IA 12168-85-3
10034-77-2
12042-78-3
12068-35-8
13397-24-5
65997-15-1
PROCLEAN FLUX REMOVER/MCC-PRO
6604 CADMIUM ORANGE SPEEDBALL ACRYLIC ARTIST COLORS
BARIUM SULFATE SUSPENSION 7727-43-7
14808-60-7
15008 HYDROXYACETONE 95% 116-09-6
26072 HYPOCHLORITE SOLUTION FOR FREE AMMONIA 1310-58-3
7732-18-5
26183 MONOCHLORAMINE REAGENT POWDER 54-21-7
68-04-2
868-18-8
1310-66-3
13755-38-9
15160 MONTMORILLONITE K10 1318-93-0
HYDRAULIC CEMENT TYPE I-II 65997-15-1
12168-85-3
10034-77-2
12042-78-3
12068-35-8
13397-24-5

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net