DISPLAYTECH INC -- PHENYLBENZOATE, MDW158
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CGVDD
MSDS NAME: PHENYLBENZOATE, MDW158
Responsible Party
Name: DISPLAYTECH INC
Address: 2602 CLOVER BASIN DR
City: LONGMONT CO 80503
Info Phone: 303-530-4750
Emergency Phone Number: 303-530-4750
Preparer's Name: MICHAEL WAND
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: DISPLAYTECH INC
Address: 2602 CLOVER BASIN DR
City: LONGMONT CO 80503
Phone: 303-530-4750
=======================================================
Ingredients
=======================================================
Cas: 93-99-2
RTECS #: DH6299500
Name: BENZOIC ACID, PHENYL ESTER; (PHENYLBENZOATE)
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: DATA NOT AVAILABLE. TOXICOLOGICAL PROPERTIES OF THIS
SUBSTANCE HAVE NOT BEEN FULLY INVESTIGATED. HANDLE WITH THE SAME PRECAUTIONS
AS ANY POTENTIALLY TOXIC SUBSTANCE.
Explanation Of Carcinogenicity: NOT RELEVANT
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: DATA NOT AVAILABLE.
First Aid: INGEST: CALL MD IMMEDIATELY (FP N). SKIN: FLUSH THOROUGHLY WITH
WATER; WASH WITH SOAP AND WATER. EYES: FLUSH WITH COPIOUS AMOUNTS OF WATER
FOR AT LEAST 15 MINUTES; GET MEDICAL ATTENTION. INHAL: IF RES PIRATORY
FAILURE OCCURS GIVE ARTIFICIALRESPIRATION.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: AVOID INHALATION OF COMPOUND. USE APPROPRIATE NIOSH
APPROVED RESPIRATOR, GLOVES, GOGGLES AND LAB COAT. CONTAIN THE MATERIAL. WASH
AREA WITH SOAP AND WATER.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSAL MUST BE IN ACCORDANCE WITH FEDERAL, STATE AND
LOCAL REGULATIONS (FP N). DISPOSE IN AN APPROVED LANFILL OR SEND TO A
LICENSED TREATMENT, STORAGE AND DISPOSAL FACILITY.
Handling And Storage Precautions: NONE SPECIFIED BY MANUFACTURER.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: CARBON DIOXIDE, FOAM OR DRY CHEMICAL.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA AND FULL PROTECTIVE EQUIPMENT
(FP N).
Unusual Fire/Explosion Hazard: WHEN HEATED TO DECOMPOSITION IT EMITS TOXIC
FUMES OF CARBON MONOXIDE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH APPROVED RESPIRATOR.
Ventilation: PROVIDE ADEQUATE GENERAL MECHANICAL AND LOCAL EXHAUST (75-100
CFM).
Protective Gloves: RUBBER GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPROVED EYE WASH & DELUGE SHOWER (FP N). LAB
COAT.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >662F,>350C
M.P/F.P Text: 95.0F,35.0C
Solubility in Water: INSOLUBLE
Appearance and Odor: WHITE SOLID; NO SPECIFIC ODOR.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: FIRE OR EXCESS HEAT.
Materials To Avoid: ACIDS. ALKALI AND OXIDIZING AGENTS.
Hazardous Decomposition Products: CO*X.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: PHENYLBENZOATE, MDW158
Company: DISPLAYTECH INC
Street: 2602 CLOVER BASIN DR
City: LONGMONT CO
Zipcode: 80503
Health Emergency Phone: 303-530-4750
Label Required IND: Y
Date Of Label Review: 04/13/1998
Status Code: C
Label Date: 04/13/1998
Origination Code: G
Eye Protection IND: YES
Skin Protection IND: YES
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: None
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: ACUTE/CHRONIC: NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.