UNIVERSAL PAINT CORP -- MIROFLEX LATEX GLOSS ENAMEL, 460
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CHSHS
MSDS NAME: MIROFLEX LATEX GLOSS ENAMEL, 460
Responsible Party
Name: UNIVERSAL PAINT CORP
Address: 111 HUDSON AVE
City: INDUSTRY CA 91744
Info Phone: 818-961-6271
Emergency Phone Number: 818-961-6271
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: UNIVERSAL PAINT COPR
Address: 111 HUDSON AVE
City: INDUSTRY CA 91744
Phone: 818-961-6271
=======================================================
Ingredients
=======================================================
Cas: 25265-77-4
RTECS #: UF6000000
Name: PROPIONIC ACID, 2-METHYL-, MONOESTER WITH
2,2,4-TRIMETHYL-1,3-PENTANEDIOL; (METHYL PENTANEDIOL MONOISOBUTYRATE). VP:
125
% Wt: 1.5
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 124-68-5
RTECS #: UA5950000
Name: 2-AMINO-2-METHYL-1-PROPANOL; (AMINO METHYL PROPANOL). VP: 239
% Wt: 0.1
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
Cas: 57-55-6
RTECS #: TY2000000
Name: PROPYLENE GLYCOL. VP: <0.1
% Wt: 2.6
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
------------------------------
RTECS #: 9999999VO
Name: VOLATILE ORGANIC COMPOUND: 250 G/L MAXIMUM.
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: ACUTE AND CHRONIC: NONE.
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: SEE HEALTH HAZARDS.
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: INGEST: CALL MD IMMEDIATELY (FP N). SKIN: WASH WITH SOAP AND WATER.
REMOVE CONTAMINATED CLOTHING. EYES: FLUSH WITH WATER FOR AT LEAST 15 MINUTES.
INHAL: REMOVE INDIVIDUAL TO FRESH AIR.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ABSORB LIQUID ON PAPER, VERMICULITE, FLOOR ABSORBENT.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DESTROY BY LIQUID INCINERATION. CONTAMINATED ABSORBENT
MAY BE DEPOSITED IN LANDFILL. CHECK LOCAL, STATE OR FEDERAL REQUIREMENTS.
Handling And Storage Precautions: NONE.
Other Precautions: NONE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Text: >200F,>93C
Lower Limits: 0.5%
Extinguishing Media: WATER FOG, CARBON DIOXIDE.
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: VAPORS ARE HEAVIER THAN AIR AND MAY TRAVEL ALONG
THE GROUND OR BE MOVED BY VENTILATION AND IGNITED BY HEAT.
=======================================================
Control Measures
=======================================================
Respiratory Protection: A NIOSH APPROVED AIR SUPPLIED RESPIRATOR IS ADVISED IN
ABSENCE OF PROPER ENVIRONMENTAL CONTROL.
Ventilation: PROVIDE SUFFICIENT MECHANICAL VENTILATION TO MAINTAIN EXPOSURE
BELOW LEVEL OF OVEREXPOSURE.
Protective Gloves: RESISTANT, I.E. BUNA-N GLOVES.
Eye Protection: ANSI APPRVD CHEM WORKERS GOGGLES (FP N).
Other Protective Equipment: ANSI APPRVD EYE WASH & DELUGE SHOWER (FP N). TO
PVNT RPTD/PRLNGD SKIN CONTACT, WEAR IMPERVIOUS CLTHG & BOOTS.
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: >212F,>100C
Vapor Pres: SEE INGS
Vapor Density: HVR/AIR
Spec Gravity: 1.28 (FP N)
Evaporation Rate & Reference: SLOWER THAN ETHER
Solubility in Water: NOT KNOWN
Appearance and Odor: NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume: 62
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: STRONG OXIDIZING AGENTS.
Materials To Avoid: STRONG OXIDIZING AGENTS.
Hazardous Decomposition Products: MAY FORM CARBON DIOXIDE, CARBON MONOXIDE.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: MIROFLEX LATEX GLOSS ENAMEL, 460
Company: UNIVERSAL PAINT COPR
Street: 111 HUDSON AVE
City: INDUSTRY CA
Zipcode: 91744
Health Emergency Phone: 818-961-6271
Label Required IND: Y
Date Of Label Review: 07/14/1998
Status Code: C
Label Date: 07/14/1998
Origination
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: None
Contact Hazard: None
Fire Hazard: Slight
Reactivity Hazard: None
Hazard And Precautions: ACUTE AND CHRONIC: NONE LISTED BY MANUFACTURER.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.