phosphor powder (nuisance dust) yttrium oxide serium terbium magnesium aluminate; (cerium terbium magnesium aluminate) barium magnesium aluminate krypton-85 mercury (sara 313) (cercla) supdat: of these lamps placed in ordinary trash may not appreciably ing 7: lamps are added to other regulated wastes or disposed in large ing 8: regulated. customers should review their waste handling practices ing 9: disposing of waste lamps and according to federal, state and local
PHILIPS LIGHTING DIV N. AMERIC -- COMPACT FLUORESCENT LAMPS, PL-S 9W
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: CHTGR
MSDS NAME: COMPACT FLUORESCENT LAMPS, PL-S 9W
Responsible Party
Name: PHILIPS LIGHTING CO DIV N. AMERICAN PHILIPS CORP
Address: 200 FRANKLIN SQUARE DR
Box: 6800
City: SOMERSET NJ 08875
Info Phone: 908-563-3090
Emergency Phone Number: 908-563-3197
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: PHILIPS LIGHTING COMPANY
Address: 200 FRANKLIN SQUARE DRIVE
Box: 6800
City: SOMERSET NJ 08875
Phone: 207-784-3591 EXT 129
Name: PHILLIPS LIGHTING CO
Address: 200 FRANKLIN ST
City: SOMERSET NJ 08875
Phone: 607-776-3311
=======================================================
Ingredients
=======================================================
Name: PHOSPHOR POWDER (NUISANCE DUST)
% Wt: <2
OSHA PEL: 15 MG/M3 (MFR)
ACGIH TLV: 10 MG/M3 (MFR)
-----------------------------
Cas: 1314-36-9
RTECS #: ZG3850000
Name: YTTRIUM OXIDE
OSHA PEL: 1 MG/M3 (MFR)
ACGIH TLV: 3 MG/M3 (MFR)
------------------------------
Name: SERIUM TERBIUM MAGNESIUM ALUMINATE; (CERIUM TERBIUM MAGNESIUM ALUMINATE)
OSHA PEL: 10 MG/M3 (MFR)
ACGIH TLV: N/K (FP N)
-----------------------------
Name: BARIUM MAGNESIUM ALUMINATE
OSHA PEL: 10 MG/M3 (MFR)
ACGIH TLV: N/K (FP N)
-----------------------------
Name: KRYPTON-85
% Wt: <15 NCI
OSHA PEL: N/K (FP N)
ACGIH TLV: N/K (FP N)
-----------------------------
Cas: 7439-97-6
RTECS #: OV4550000
Name: MERCURY (SARA 313) (CERCLA)
% Wt: <0.02
OSHA PEL: C, 0.1 MG/M3; Z-2
ACGIH TLV: S,0.025 MG/M3; A4;95
EPA Rpt Qty: 1 LB
DOT Rpt Qty: 1 LB
------------------------------
Name: SUPDAT: OF THESE LAMPS PLACED IN ORDINARY TRASH MAY NOT APPRECIABLY
AFFECT THE METHOD OF LAMP DISPOSAL. IF SPENT
-----------------------------
Name: ING 7: LAMPS ARE ADDED TO OTHER REGULATED WASTES OR DISPOSED IN LARGE
QUANTITIES, DISPOSAL OF LAMPS MAY BE
-----------------------------
Name: ING 8: REGULATED. CUSTOMERS SHOULD REVIEW THEIR WASTE HANDLING PRACTICES
TO ASSURE THAT THEY ARE PROPERLY
-----------------------------
Name: ING 9: DISPOSING OF WASTE LAMPS AND ACCORDING TO FEDERAL, STATE AND LOCAL
REGULATIONS.
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: NONE SPECIFIED BY MANUFACTURER.
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Explanation Of Carcinogenicity: NOT RELEVANT.
Signs And Symptions Of Overexposure: HLTH HAZ: THROUGH THE USE OF ADEQUATE
VENTILATION DURING DISPOSAL OF LARGE QUANTITIES OF LAMPS. MERCURY APPEARS ON
THE NAVY LISTING OF OCCUPATIONAL CHEMICAL REPRODUCTIVE HAZARDS. SEEK
CONSULTATION FRO M APPROPRIATE HEALTH PROFESSIONALS CONCERNING LATEST HAZARD
LIST INFORMATION & SAFE HANDLING & EXPOSURE INFO (FP N).
Medical Cond Aggravated By Exposure: NONE SPECIFIED BY MANUFACTURER.
First Aid: NORMAL FIRST AID PROCEDURE FOR GLASS CUTS IF SUCH OCCUR THROUGH LAMP
BREAKAGE. INGEST: CALL MD IMMEDIATELY (FP N). INHAL: REMOVE TO FRESH AIR.
SUPPORT BREATHING (GIVE O*2/ARTF RESP) (FP N). EYES: IMME DIATELY FLUSH
W/POTABLE WATER FOR A MINIMUM OF 15 MINUTES, SEEK ASSISTANCE FROM MD (FP N).
SKIN: FLUSH W/COPIOUS AMOUNTS OF WATER. CALL MD (FP N).
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: NORMAL PRECAUTIONS SHOULD BE TAKEN FOR COLLECTION OF
BROKEN GLASS.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: UNDER NEW TOXICITY CHARACTERISTIC LEACHING PROCEDURES
(TCLP) PROMULGATED BY US ENVIRONMENTAL PROTECTION AGENCY (EPA), TESTS OF
USED/SPENT FLUORESCENT, INCANDESCENT, & HIGH INTENSITY DISCHARGE LAMPS IN
DICATE THAT SOME TYPES OF THESE (SUPDAT)
Handling And Storage Precautions: APPROPRIATE HAND AND EYE PROTECTION SHOULD BE
WORN WHEN DISPOSING OF LAMPS OR HANDLING BROKEN GLASS.
Other Precautions: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: MEDIA SUITABLE FOR SURROUNDING FIRE (FP N).
Fire Fighting Procedures: USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT (FP N).
Unusual Fire/Explosion Hazard: UNDER EXTREME HEAT, GLASS ENVELOPE MIGHT MELT OR
CRACK.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NIOSH-APPROVED RESPIRATOR MIGHT BE USED IF LARGE
VOLUMES OF LAMPS ARE BEING BROKEN FOR DISPOSAL.
Ventilation: AVOID INHALATION OF ANY AIRBORNE DUST. PROVIDE LOCAL EXHAUST WHEN
DISPOSING LARGE QUANTITIES OF LAMPS.
Protective Gloves: IMPERVIOUS GLOVES (FP N).
Eye Protection: ANSI APPROVED CHEM WORKERS GOGGS (FP N).
Other Protective Equipment: EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET ANSI
DESIGN CRITERIA (FP N).
Work Hygienic Practices: NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health: WASTE DISP METH: LAMPS MAY BE CLASSIFIED AS
CHARACTERISTIC HAZ WASTE. NOTABLY, TCLP TEST RSLTS FOR FLUORESCENT LAMPS VARY
TREMENDOUSLY FROM LAB TO LAB. LAMPS FROM ALL MFRS EXHIBIT SAME PHENOMENA. THE
NATIONAL ELECTRICAL MFRS ASSOCIATION (NEMA) IS WORKING CLOSELY W/EPA FOR
CLARIFICATION & GUIDANCE. SMALL NUMBERS
=======================================================
Physical/Chemical Properties
=======================================================
Appearance and Odor: THIS IS A LIGHT BULB WITH GLASS TUBES AND PLASTIC BASE.
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: NONE SPECIFIED BY MANUFACTURER.
Materials To Avoid: GLASS WILL REACT WITH HYDROFLUORIC ACID.
Hazardous Decomposition Products: NONE SPECIFIED BY MANUFACTURER.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: NOT RELEVANT.
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: COMPACT FLUORESCENT LAMPS, PL-S 9W
Company: PHILIPS LIGHTING COMPANY
Street: 200 FRANKLIN SQUARE DRIVE
PO Box: 6800
City: SOMERSET NJ
Zipcode: 08875
Health Emergency Phone: 908-563-3197
Label Required IND: Y
Date Of Label Review: 07/22/1998
Status Code: C
Label Date: 07/22/1998
Origination
Chronic Hazard IND: Y
Eye Protection IND: YES
Skin Protection IND: YES
Signal Word: CAUTION
Respiratory Protection IND: YES
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: Slight
Reactivity Hazard: None
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.