perfluorinated polyether (pfpe) polytetrafluoroethylene (ptfe) no hazardous ients contained
LUBRICATION TECHNOLOGY INC -- CHRISTO-LUBE MCG 111
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 01-441-9016
MSDS Num: CJQBX
MSDS NAME: CHRISTO-LUBE MCG 111
Responsible Party
Name: LUBRICATION TECHNOLOGY INC
Address: 310 MORTON ST
City: JACKSON OH 45640
Info Phone: 614-286-2644
Emergency Phone Number: 740-286-2644
Published: Y
=======================================================
Contractor Summary
=======================================================
Name: LUBRICATION TECHNOLOGY INC
Address: 310 MORTON ST
City: JACKSON OH 45640
Phone: 740-286-2644
Contract Number: SP0450-00-M-C224
Name: LUBRICATION TECHNOLOGY INC
Address: 310 MORTON ST
City: JACKSON OH 45640
Phone: 740-286-2644
Contract Number: SP0450-99-M-NF58
=======================================================
Item Description Information
=======================================================
Item Manager: S9G
Item Name: GREASE,AIRCRAFT AND INSTRUMENT
Unit of Issue: TU
Quantitative Expression: 00000000002OZ
UI Container Qty: 1
Type of Container: TUBE
=======================================================
Ingredients
=======================================================
Cas: 69991-61-3
Name: PERFLUORINATED POLYETHER (PFPE)
-----------------------------
Cas: 9002-84-0
RTECS #: KX4025000
Name: POLYTETRAFLUOROETHYLENE (PTFE)
------------------------------
Name: NO HAZARDOUS INGREDIENTS CONTAINED
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: LD50 (ORAL RAT) IS >5000 MG/KG
Route Of Entry Inds - Inhalation: NO
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: INHALATION: SLIGHTLY TOXIC BY INHALATION (4 HR. LC50
1000-5000 PPM: 8-40-MG/L). SKIN: VERY LOW TOXICITY BY CONTACT (LD50
>10,000 MG/KG). INGESTION: VERY LOW TOXICITY BY INGESTION (ORAL LD50
>5000MG/ KG). HEALTH HAZARDS (ACUTE AND CHRONIC): NONE.
Explanation Of Carcinogenicity: NONE.
Signs And Symptions Of Overexposure: MILD IRRITANT TO THE SKIN UPON
PROLONGED/REPEATED EXPOSURE IN SOME INDIVIDUALS. DECOMPOSITION PRODUCTS
FORMED AT HIGH TEMPERATURES MAY CAUSE "POLYMER FEVER."
Medical Cond Aggravated By Exposure: NONE KNOWN.
First Aid: NONE PROVIDED BY MANUFACTURER.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: USE ABSORBENT MATERIAL TO COLLECT AND CONTAIN FOR
SALVAGE AND DISPOSAL.
Neutralizing Agent: NONE SPECIFIED BY MANUFACTURER.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS.
Handling And Storage Precautions: DO NOT STORE NEAT FLAMMABLE OR EXPLOSIVE
MATERIALS.
Other Precautions: TOXIC VAPORS MAY EVOLVE ABOVE 290C. PROVIDE ADEQUATE
VENTILATION IF PRODUCT IS USED ABOVE THIS TEMPERATURE.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Fire Fighting Procedures: SELF CONTAINED BREATHING APPARATUS AND PROTECTIVE
CLOTHING RECOMMENDED.
Unusual Fire/Explosion Hazard: DECOMPOSITION AT TEMPERATURES ABOVE 290C MAY
CAUSE THE EVOLUTION OF TOXIC GASEOUS FLUORINE COMPOUNDS.
=======================================================
Control Measures
=======================================================
Respiratory Protection: NOT REQUIRED UNDER NORMAL CONDITIONS.
Ventilation: MECHANICAL RECOMMENDED.
Protective Gloves: PLASTIC DISPOSABLE RECOMMENDED
Eye Protection: SAFETY GLASSES RECOMMENDED
Other Protective Equipment: PLASTIC DISPOSABLE APRON OR COVERALLS RECOMMENDED.
Work Hygienic Practices: DO NOT CONTAMINATE FOOD OR SMOKING MATERIALS. WASH
HANDS AFTER EXPOSURE.
Supplemental Safety and Health: NONE PROVIDED BY MANUFACTURER.
=======================================================
Physical/Chemical Properties
=======================================================
HCC: N1
Melt/Freeze Pt: >250.C, 482.F
Vapor Pres: <0.001 MM @ 20C
Spec Gravity: 1.990 (H20=1)
Solubility in Water: INSOLUBLE
Appearance and Odor: WHITE, ODORLESS
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: AVOID HEATING ABOVE 290C.
Materials To Avoid: STRONG OR NOT AQUEOUS ALKALI AND LEWIS ACIDS ABOVE 100C.
Hazardous Decomposition Products: TOXIC HF AND COF2 FROM THERMAL DECOMPOSITION
IN AIR.
Hazardous Polymerization Indicator: NO
Conditions To Avoid Polymerization: AVOID HEATING ABOVE 290C.
=======================================================
Toxicological Information
=======================================================
Toxicological Information: THRESHOLD LIMIT VALUE: LD50 >40 G/KG. OSHA
THRESHOLD VALUE: LD50 >40 G/KG. ACGIH THRESHOLD LIMIT VALUE: LD50 >40
G/KG. FREE OF OZONE DEPLETING COMPOUNDS.
=======================================================
Ecological Information
=======================================================
Ecological: NONE SPECIFIED BY MANUFACTURER.
=======================================================
MSDS Transport Information
=======================================================
Transport Information: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Regulatory Information
=======================================================
Sara Title III Information: NONE SPECIFIED BY MANUFACTURER.
Federal Regulatory Information: NONE SPECIFIED BY MANUFACTURER.
State Regulatory Information: NONE SPECIFIED BY MANUFACTURER.
=======================================================
Other Information
=======================================================
Other Information: FREE OF OZONE DEPLETING COMPOUNDS.
=======================================================
Transportation Information
=======================================================
Trans ID NO: 149270
MSDS NAME: CHRISTO-LUBE MCG 111
MSDS Prepared Date: 11/24/1998
Review Date: 10/16/1999
Multiple KIT Number: 0
Unit Of Issue: TU
Container QTY: 1
Type Of Container: TUBE
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: CHRISTO-LUBE MCG 111
Company: LUBRICATION TECHNOLOGY INC
Street: 310 MORTON ST
City: JACKSON OH
Zipcode: 45640
Health Emergency Phone: 740-286-2644
Label Required IND: Y
Date Of Label Review: 10/16/1999
Status Code: A
Origination Code: F
Signal Word: CAUTION
Health Hazard: Slight
Contact Hazard: Slight
Fire Hazard: None
Reactivity Hazard: None
Hazard And Precautions: TARGET ORGANS: NOT SPECIFIED BY MANUFACTURER.
INHALATION: SLIGHTLY TOXIC. SKIN: VERY LOW TOXICITY BY CONTACT. INGESTION:
VERY LOW TOXICITY.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.