ALEXANDER BATTERY -- R2931, NICAD BATTERY, SEALED
=======================================================
Material Safety Data Sheet
=======================================================
NIIN: 01-388-3584
MSDS Num: CKDKP
MSDS NAME: R2931, NICAD BATTERY, SEALED
Article: Y
Responsible Party
Name: ALEXANDER BATTERY
Address: 1511 GARFIELD PL
Box: UNKNOW
City: MASON CITY IA 50401
Info Phone: 800-247-1821;515-423-8955
Emergency Phone Number: 515-423-8955
=======================================================
Item Description Information
=======================================================
Item Manager: S9G
Item Name: BATTERY,STORAGE
Unit of Issue: EA
UI Container Qty: 0
=======================================================
Regulated Components
=======================================================
Regulated Component Name: POTASSIUM HYDROXIDE AS DRY HYDROXIDE
Percent Text: 2-4%
Regulated Component Name: NICKEL AND NICKEL HYDROXIDE
Percent Text: 20-30%
Regulated Component Name: CADMIUM AND CADMIUM HYDROXIDE
Percent Text: 13-15%
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ORAL LD50(RAT): UNKNOWN
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Explanation Of Carcinogenicity: NO INFO AVAILABLE
Signs And Symptions Of Overexposure: UNDER NORMAL USE, R2931 BATTERY DOES NOT
RELEASE TOXIC MATERIAL.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: ELECTROLYTE, POTASSIUM HYDROXIDE IS CAUSTIC. DO
NOTALLOW SKIN OR EYE CONTACT. FLUSH WITH WATER. THERE IS ONLY A TRACE AMOUNT
OF POTASSIUM HYDROXIDE AVAILABLE IN THE BATTERY.
Waste Disposal Methods: DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.
Handling And Storage Precautions: DO NOT INCINERATE OR MUTILATE; MAY BURST
RELEASING TOXIC MATERIAL (CADMIUM FUMES).
Other Precautions: DO NOT SHORT CIRCUIT THE BATTERY, IT MAY CAUSE BURNS WHEN IN
CONTACT WITH SKIN AND EYES.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: NO INFO AVAILABLE.
Fire Fighting Procedures: WEAR SELF-CONTAINED BREATHING APPARATUS IFLARGE
QUANTITIES OF BATTERIES ARE ON FIRE. WAREHOUSE OR DEPOT TYPE STORAGE.
Unusual Fire/Explosion Hazard: CADMIUM FUMES MAY BE RELEASED DURING BURNING.
=======================================================
Control Measures
=======================================================
Eye Protection: NA
=======================================================
Physical/Chemical Properties
=======================================================
HCC: Z5
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: BURNING (FIRE), RUPTURING
Hazardous Decomposition Products: CADMIUM FUMES MAY BE RELEASED DURING FIRE.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
Other Information: NOTE: ALEXANDER MFG. CO. CONSIDERS THIS BATTERY AN "ARTICLE"
AS DESCRIBED IN 29 CFR 1910-1200 SECTION(C). FUTHER, THIS ARTICLE (BATTERY)
DOES NOT RELEASE OR OTHERWISE RESULT IN EXPOSURE TO A HAZARDOUS CHEMICAL
UNDER THE CONDITIONS OF YOUR INTENDED USE. EACH CELL OF THE BATTERY IS A
SEALED CONTAINER ENCLOSING A NICKEL ELECTRODE, A CADMIUM ELECTRODE AND
POTASSIUM HYDROXIDE ELECTROLYTE.
=======================================================
Transportation Information
=======================================================
Trans ID NO: 151824
MSDS NAME: R2931, NICAD BATTERY, SEALED
MSDS Prepared Date: 02/01/1994
Review Date: 03/08/2000
Multiple KIT Number: 0
Review IND: Y
Unit Of Issue: EA
Container QTY: 0
=======================================================
Detail DOT Information
=======================================================
DOT PSN Code: ZZZ
DOT Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail IMO Information
=======================================================
IMO PSN Code: ZZZ
IMO Proper Shipping Name: NOT REGULATED FOR THIS MODE OF TRANSPORTATION
=======================================================
Detail IATA Information
=======================================================
IATA PSN Code: ZZZ
IATA Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
Detail AFI Information
=======================================================
AFI PSN Code: ZZZ
AFI Proper Shipping Name: NOT REGULATED BY THIS MODE OF TRANSPORTATION
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: R2931, NICAD BATTERY, SEALED
Company: ALEXANDER BATTERY
Street: 1511 GARFIELD PL
PO Box: UNKNOW
City: MASON CITY IA
Zipcode: 50401
Health Emergency Phone: 515-423-8955
Label Required IND: Y
Date Of Label Review: 03/08/2000
Status Code: A
Year Procured: 2000
Origination Code: F
Signal Word: NONE
Health Hazard: None
Contact Hazard: None
Fire Hazard: None
Reactivity Hazard: None
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.