LIQUID CARBONIC INDUSTRIES COR -- P 10 GAS MIXTURE
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWJSZ
MSDS NAME: P 10 GAS MIXTURE
Responsible Party
Name: LIQUID CARBONIC INDUSTRIES CORP
Address: 810 JORIE BLVD
City: OAK BROOK IL 60521-2216
Info Phone: 708-572-7500/504-673-8831
Emergency Phone Number: 708-572-7500/504-673-8831
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Name: LIQUID CARBONIC INDUSTRIES CORP
Address: 810 JORIE BLVD
City: HINSDALE IL 60521-2216
=======================================================
Contractor Summary
=======================================================
Name: LIQUID CARBONIC INDUSTRIES CORP
Address: 810 JORIE BLVD
City: HINSDALE IL 60521-2216
Phone: 708-572-7000
=======================================================
Ingredients
=======================================================
Cas: 74-82-8
RTECS #: PA1490000
Name: METHANE
% Wt: 10
ACGIH TLV: SIMPLE ASPHYXIANT
------------------------------
Cas: 7440-37-1
RTECS #: CF2300000
Name: ARGON
% Wt: 90
ACGIH TLV: SIMPLE ASPHYXIANT
=======================================================
Health Hazards Data
=======================================================
Route Of Entry Inds - Inhalation: YES
Skin: NO
Ingestion: NO
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: DIZZINESS, DROWSINESS, UNCONSCIOUSNESS
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: DIZZINESS, DROWSINESS, UNCONSCIOUSNESS
First Aid: INHALATION: REMOVE TO FRESH AIR. IF UNCONSCIOUSNESS/BREATHING IS
DIFFICULT ADMINISTER CPR W/SUPPLEMENTAL OXYGEN. KEEP WARM & AT REST.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: EVACUATE ALL PERSONNEL UPWIND & AWAY FROM
AFFECTED AREA. STOP LEAK IF POSSIBLE. IF LEAKING CONTAINER IS IN AN ENCLOSED
AREA, VENTILATE TO ACCEPTABLE RESPIRABLE OXYGEN LEVEL BEFORE ENTERING.
Waste Disposal Methods: LOCATE LEAKING CONTAINERS IN A REMOTE DOWNWIND AREA
OUTSIDE & ALLOW TO VENT TO ATMOSPHERE. DISPOSE OF IAW/FEDERAL, STATE
& LOCAL REGULATIONS.
Handling And Storage Precautions: PROTECT AGAINST PHYSICAL DAMAGE. USE A
PRESSURE REDUCING REGULATOR WHEN CONNECTING CYLINDER TO LOWER PRESSURE
PIPING/SYSTEMS. (SEE SUPP)
Other Precautions: CLOSE VALVE AFTER EACH USE & WHEN EMPTY. CYLINDERS MAY
NOT BE REFILLED EXCEPT BY/W THE CONSENT OF LIQUID CARBONIC. STORE IN A COOL,
DRY, WELL-VENTILATED AREA, AWAY FROM SOURCES OF HEAT/DIRECT SUNLIGHT . DON'T
STORE >125F. (SEE SUPP)
=======================================================
Fire and Explosion Hazard Information
=======================================================
Extinguishing Media: NONFLAMMABLE GAS MIXTURE
Fire Fighting Procedures: IF CYLINDERS ARE INVOLVED IN A FIRE, SAFELY
RELOCATE/KEEP COOL W/WATER SPRAY.
Unusual Fire/Explosion Hazard: NONE
=======================================================
Control Measures
=======================================================
Respiratory Protection: IN EVENT OF MAJOR LEAK, SCBA MAY BE REQUIRED.
Ventilation: LOCAL EXHAUST/MECHANICAL: TO PREVENT ACCUMULATION SO AS TO EXCLUDE
AN ADEQUATE OXYGEN SUPPLY.
Protective Gloves: ANY MATERIAL
Eye Protection: SAFETY GOGGLES/GLASSES
Other Protective Equipment: SAFETY SHOES.
Supplemental Safety and Health: HANDLING & STORAGE CONT'D: CYLINERS SHOULD
BE STORED UPRIGHT & FIRMLY SECURED. OTHER PRECAUTIONS CONT'D: USE A CHECK
VALVE/TRAP IN THE CYLINDER DISCHARGE LINE TO PREVENT BACKFLOW. BOILING POINT
INFORM ATION IS FOR ARGON.
=======================================================
Physical/Chemical Properties
=======================================================
B.P. Text: -302.6F
Vapor Density: 1.34
Solubility in Water: NEGLIGIBLE
Appearance and Odor: COLORLESS, ODORLESS GAS
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: SOURCES OF HEAT, DIRECT SUNLIGHT
Materials To Avoid: NONE
Hazardous Decomposition Products: NONE
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: P 10 GAS MIXTURE
Company: LIQUID CARBONIC INDUSTRIES CORP
Street: 810 JORIE BLVD
City: HINSDALE IL
Zipcode: 60521-2216
Health Emergency Phone: 708-572-7500/504-673-8831
Label Required IND: Y
Date Of Label Review: 12/16/1998
Status Code: C
Label Date: 12/16/1998
Origination Code: G
Hazard And Precautions: DIZZINESS, DROWSINESS, UNCONSCIOUSNESS
DIZZINESS,
DROWSINESS, UNCONSCIOUSNESS
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.