SPI SUPPLIES/STRUCTURE PROBE -- SPI 5060/5061 SILVER PASTE FOR E M
=======================================================
Material Safety Data Sheet
=======================================================
MSDS Num: BWJVY
MSDS NAME: SPI 5060/5061 SILVER PASTE FOR E M
Responsible Party
Name: SPI SUPPLIES/STRUCTURE PROBE
Address: 569 E GAY ST
Box: 656
City: WEST CHESTER PA 19381-0656
Info Phone: 215-436-5400
Emergency Phone Number: 215-436-5400
Proprietary Ind: Y
Review Ind: Y
Published: Y
=======================================================
Preparer Co. when other than Responsible Party Co.
=======================================================
Assigned Ind: Y
Name: SPI SUPPLIES/STRUCTURE PROBE
Address: 569 E GAY ST
Box: 656
City: WEST CHESTER PA 19381
=======================================================
Contractor Summary
=======================================================
Name: SPI SUPPLIES/STRUCTURE PROBE
Address: 569 E GAY ST
Box: 656
City: WEST CHESTER PA 19381
Phone: 800-242-4774 FAX: 215-436-5755
Name: STRUCTURE PROBE INC
Box: 656
City: WEST CHESTER PA 19381-0656
Phone: 610-436-5400
=======================================================
Ingredients
=======================================================
Name: *** PROPRIETARY ***
-----------------------------
=======================================================
Health Hazards Data
=======================================================
LD50 LC50 Mixture: ORAL LD50 (RATS): 2400-3000 MG/KG (SUPP)
Route Of Entry Inds - Inhalation: YES
Skin: YES
Ingestion: YES
Carcinogenicity Inds - NTP: NO
IARC: NO
OSHA: NO
Effects of Exposure: TOLUENE-SKIN/EYES: IRRITATION. INHALATION: NERVOUS SYSTEM
DEPRESSION W/ANESTHETIC EFFECTS/UPPER RESPIRATORY TRACT IRRITATION.
INGESTION: SEVERE GI TRACT IRRITATION. OVEREXPOSURE MAY CAUSE CARDIOVASCUL AR
EFFECTS/ABNORNAL LIVER & KIDNEY FUNTIONS/FATAL/NEUROLOGICAL EFFECTS.
ASPSIRATION MAY CAUSE CHEMICAL PNEUMONIA. (SUPP)
Explanation Of Carcinogenicity: NONE
Signs And Symptions Of Overexposure: IRRITATION/DISCOMFORT/RASH/TEARING/BLURRED
VISION/DEFATTING/DIZZINESS/HEADACHE/CONFUSION/INCOORDINATION/LOSS OF
CONSCIOUSNESS/NAUSEA/WEAKNESS/VOMITING/DIARRHEA/PAIN/COUGHING/GASPING/CHOKING
/SHORTNESS OF BREATH/BLUE COLORATION/FEVER/ARGYRIA/ALLERGIC
RASH/NUMBNESS/DIFFICULTY BREATHING/RAPID HEART RATE & BREATHING.
Medical Cond Aggravated By Exposure: PRE-EXISTING DISEASES OF CNS & LUNGS.
First Aid: SKIN: IMMEDIATELY WASH W/SOAP & WATER. EYES: IMMEDIATELY FLUSH
W/PLENTY OF WATER FOR 15 MINS. INHALATION: REMOVE TO FRESH AIR IMMEDIATELY.
GIVE CPR/OXYGEN IF NEEDED. INGESTION: IMMEDIATELY GIVE 2 GLAS SES OF WATER
& INDUCE VOMITING. NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
OBTAIN MEDICAL ATTENTION IN ALL CASES.
=======================================================
Handling and Disposal
=======================================================
Spill Release Procedures: SMALL: ABSORB ON RAGS/SAND/OTHER ABSORBENT MATERIAL.
LARGE: EVACUATE AREA. REMOVE ALL IGNITION SOURCES. WEAR PROTECTIVE EQUIPMENT.
CONTAIN/DIKE/ABSORB W/SAND. DON'T ALLOW TO SPREAD/INTENTIONALLY FLUSH TO
SEWER/GROUND.
Waste Disposal Methods: WASTE PRODUCT MAY BE REFINED TO RECOVER PRECIOUS METAL
CONTENT IAW/FEDERAL, STATE & LOCAL REGULATIONS.
Handling And Storage Precautions: STORE BELOW 90F TO ENSURE PRODUCT VISCOSITY
STABILITY.
Other Precautions: EMPTY PRODUCT CONTAINERS, CONTAMINATED CLOTHING &
CLEANING MATERIALS SHOULD BE CONSIDERED HAZARDOUS UNTIL
DECONTAMINATED/PROPERLY DISPOSED OF. DON'T SMOKE, CONSUME/STORE FOOD/DRINKS
IN AREAS WHERE PRO DUCT IS HANDLED/STORED.
=======================================================
Fire and Explosion Hazard Information
=======================================================
Flash Point Method: CC
Flash Point Text: 128F
Extinguishing Media: WATER SPRAY, DRY CHEMICAL, CO2.
Fire Fighting Procedures: WEAR SCBA W/FULL FACEPIECE IN POSITIVE PRESSURE MODE
& FULL PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard: VAPORS MAY IGNITE IF EXPOSED TO OPEN SPARKS,
FLAMES/STATIC DISCHARGE.
=======================================================
Control Measures
=======================================================
Respiratory Protection: WEAR APPROPRIATE NIOSH/MSHA APPROVED RESPIRATOR
DEPENDING ON PROPERTIES OF CONTAMINANTS & THEIR ACTUAL/EXPECTED AIR
CONCENTRATION VERSUS APPLICABLE LIMITS.
Ventilation: LOCAL EXHAUST TO KEEP EXPOSURES BELOW APPLICABLE LIMITS.
Protective Gloves: NITRILE-BUTADIENE RUBBER/POLYETHYLENE
Eye Protection: CHEMICAL SPLASH GOGGLES
Other Protective Equipment: VINYL GLOVES, PROTECTIVE OUTER CLOTHING
Work Hygienic Practices: REMOVE/LAUNDER CONTAMINATED CLOTHING BEFORE REUSE.
WASH HANDS THOROUGHLY AFTER HANDLING/BEFORE LEAVING WORK AREA.
Supplemental Safety and Health: ORAL LD50 INFORMATION IS FOR ETHYLENE GLYCOL
MONOBUTYL ETHER ACETATE. HEALTH HAZARDS CONT'D: 1-METHOXY-2-PROPANOL
ACETATE/ACRYLIC RESIN-IRRITANT. ETHYLENE GLYCOL MONOBUTYL ETHER
ACETATE-SKIN/EYE IRRIT ANT. SYSTEMIC TOXICITY & ABNORMAL BLOODFORMING
SYSTEM FUNCTION W/ANEMIA. METHYL METHACRYLATE-IRRITANT/ULCERATION.
=======================================================
Physical/Chemical Properties
=======================================================
Solubility in Water: SLIGHT
Appearance and Odor: GREY VISCOUS LIQUID W/AROMATIC ODOR
=======================================================
Reactivity Data
=======================================================
Stability Indicator: YES
Stability Condition To Avoid: SPARKS, OPEN FLAMES, STATIC DISCHARGE, OTHER
IGNITION SOURCES, HIGH TEMPS.
Materials To Avoid: REDUCING AGENTS, OXIDIZING AGENTS, BASES, ACIDS.
Hazardous Decomposition Products: CO, CO2, WATER, ETHYL METHACRYLATE, METHYL
ACRYLATE.
Hazardous Polymerization Indicator: NO
=======================================================
Toxicological Information
=======================================================
=======================================================
Ecological Information
=======================================================
=======================================================
MSDS Transport Information
=======================================================
=======================================================
Regulatory Information
=======================================================
=======================================================
Other Information
=======================================================
=======================================================
HAZCOM Label
=======================================================
MSDS NAME: SPI 5060/5061 SILVER PASTE FOR E M
Assigned IND: Y
Company: SPI SUPPLIES/STRUCTURE PROBE
Street: 569 E GAY ST
PO Box: 656
City: WEST CHESTER PA
Zipcode: 19381
Health Emergency Phone: 215-436-5400
Label Required IND: Y
Date Of Label Review: 12/16/1998
Status Code: C
Label Date: 12/16/1998
Origination Code: G
Hazard And Precautions: TOLUENE-SKIN/EYES: IRRITATION. INHALATION: NERVOUS
SYSTEM DEPRESSION W/ANESTHETIC EFFECTS/UPPER RESPIRATORY TRACT IRRITATION.
INGESTION: SEVERE GI TRACT IRRITATION. OVEREXPOSURE MAY CAUSE CARDIOVASCUL AR
EFFECTS/ABNORNAL LIVER & KIDNEY FUNTIONS/FATAL/NEUROLOGICAL EFFECTS.
ASPSIRATION MAY CAUSE CHEMICAL PNEUMONIA.
(SUPP)IRRITATION/DISCOMFORT/RASH/TEARING/BLURRED
VISION/DEFATTING/DIZZINESS/HEADACHE/C ONFUSION/INCOORDINATION/LOSS OF
CONSCIOUSNESS/NAUSEA/WEAKNESS/VOMITING/DIARRHEA/PAIN/COUGHING/GASPING/CHOKING
/SHORTNESS OF BREATH/BLUE COLORATION/FEVER/ARGYRIA/ALLERGIC
RASH/NUMBNESS/DIFFICULTY BREATH ING/RAPID HEART RATE & BREATHING.
=======================================================
Disclaimer (provided with this information by the compiling agencies): This
information is formulated for use by elements of the Department of Defense.
The United States of America in no manner whatsoever expressly or implied
warrants, states, or intends said information to have any application, use or
viability by or to any person or persons outside the Department of Defense
nor any person or persons contracting with any instrumentality of the United
States of America and disclaims all liability for such use. Any person
utilizing this instruction who is not a military or civilian employee of the
United States of America should seek competent professional advice to verify
and assume responsibility for the suitability of this information to their
particular situation regardless of similarity to a corresponding Department
of Defense or other government situation.