ing 14:concs in rat's lungs showed that the gag clearance ing 15:massive 250 mg/m3 level are not relevant to fluoropolymer solids sulfuric acid, monododecyl ester, sodium salt (sodium toluene (sara iii) titanium dioxide supp data:ovens must be properly vent. at temps above 750f ing 5:amts incr as temp incr. hydrogen fluoride is toxic & ing 6:concs can cause lung dmg, pulm edema/burns. some ing 7:attn must be given to exhaust locations. sodium ing 8:irrit. rptd/prlngd cntct may cause skin irrit ing 9:overexpos may cause eye, nose & throat irrit. ing 10:may cause cns efts such as dizz, hdch, nausea & loss ing 11:overexpos to solvs w/perm brain & nervous sys dmg. ing 12:kidney efts. titanium dioxide:no known haz w/normal ing 13:were found in some rats exposed to 250 mg/m3 resp
MSDS NAME:TEFLON PRIMERS, 850-302
NIIN:00N015355
MSDS Number: BKQBK
=== Responsible Party ===
Company:E.I. DU PONT DE NEMOURS & CO
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:800-441-7515
Emergency Phone Num:800-441-3637;800-424-9300(CHEMTREC)
CAGE:18773
=== Contractor Identification ===
Company:E.I. DU PONT DE NEMOURS & CO., INC.
CAGE:18773
Company:E.I. DUPONT DE NEMOURS & CO
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:800-441-7515;800-441-9442
CAGE:18873
============= Composition/Information on Ingredients =============
Name:ING 14:CONCS IN RAT'S LUNGS SHOWED THAT THE GAG CLEARANCE
MECHANISM WAS OVERWHELMED & THAT RESULTS AT (SEE ING 16)
RTECS #:9999999ZZ
Name:ING 15:MASSIVE 250 MG/M3 LEVEL ARE NOT RELEVANT TO
WORKPLACE.
RTECS #:9999999ZZ
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:OVEREXPOS TO VAPS DURING SPRAY
APPLICATION MAY CAUSE NOSE/THROAT IRRIT. MAY CAUSE NERVOUS SYS
DEPRESS CHARACTERIZED BY FOLLOWING PROGRESSIVE STEPS:HDCH, DIZZ,
NAUSEA, STAGGERING GAIT, CONFUSION, UNCON. REPORTS HAVE ASSOC
RPTD/PRLNGD OVEREXPOS TO SOLVS W/PERM BRAIN DMG & NERVOUS SYS DMG.
(SEE EFTS OF OVEREXP)
Explanation of Carcinogenicity:NONE SPECIFIED BY MANUFACTURER.
Effects of Overexposure:HLTH HAZ:EYE:MAY CAUSE IRRIT/BURNING.
SKIN:RPTD/PRLNGD LIQ CNTCT MAY CAUSE IRRIT W/DISCOMFORT/DERM. OTHER
POTNTL HAZ INCLUDE: FLUOROPOLYMER SOLIDS:EXPOS TO TEFLON DECOMP
PRODS CAN CREATE INFLUENZA-LIK E SYMPS, COMMONLY REFERRED TO AS
POLYMER FUME FEVER. SYMPS DO NOT ORDINARILY OCCUR UNTIL SEVERAL HRS
(SEE SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BRTHG, GIVE ARTF RESP,
PREFERABLY MOUTH-TO-MOUTH. IF BRTHG DFCLTY PERSISTS/OCCURS LATER,
CALL MD. EYE:IMMED FLUSH W/PLENTY OF WATER FOR AT LEAST 15 MIN.
CALL MD. SKIN :WASH W/SOAP & WATER. IF IRRIT OCCURS, CALL MD.
INGEST:GI DISTRESS. IN UNLIKELY EVENT OF INGESTION, CALL MD IMMED &
HAVE NAMES OF INGREDIENTS AVAILABLE.
===================== Fire Fighting Measures =====================
Flash Point Method:CC
Flash Point:20.0F,-6.7C
Lower Limits:1.30%
Upper Limits:7%
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT. WATER FROM FOG NOZZLES MAY BE USED TO COOL
CLOSED CONTAINERS TO PREVENT PRESSURE BUILD-UP.
Unusual Fire/Explosion Hazard:WHEN HEATED ABOVE FLASH POINT, EMITS FLAM
VAPS WHICH, WHEN MIXED W/AIR CAN BURN/BE EXPLO. FINE MISTS/SPRAYS
MAY BE FLAMM AT TEMPS BELOW FLASH POINT. (SUPP DATA)
Spill Release Procedures:VENTILATE AREA. REMOVE SOURCES OF IGNITION.
AVOID SKIN CONTACT AND BREATHING OF VAPOR. CONFINE & REMOVE W/INERT
ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:OBSERVE LABEL PRECAUTIONS. KEEP AWAY
FROM HEAT, SPARKS, FLAME. CLOSE CNTNR AFTER EACH USE. GROUND CNTNRS
WHEN POURING. DO NOT STORE ABOVE 120F.
Other Precautions:EXPLOSIVE REACTION MAY OCCUR ABOVE 796F W/FINELY
DIVIDED FLUOROCARBON & METAL POWDER (ALUMINUM/MAGNESIUM).
OPERATIONS SUCH AS GRINDING, BUFFING, GRIT BLASTING MAY GENERATE
SUCH MIXTURES. KEEP WET. USE ADEQUATE VENTILATION TO CONTROL.
Respiratory Protection:DO NOT BREATHE VAPORS/MISTS. WEAR PROPERLY
FITTED NIOSH/MSHA APPROVED VAPOR/PARTICULATE RESPIRATOR FOR USE
W/PAINTS DURING APPLICATION & UNTIL ALL VAPORS/SPRAY MIST ARE
EXHAUSTED. FOLLOW RESPIRATOR MF R'S DIRECTIONS FOR RESPIRATOR USE.
Ventilation:PROVIDE SUFFICIENT VENTILATION IN VOLUME & PATTERN TO KEEP
CONTAMINANTS BELOW APPLICABLE OSHA REQUIREMENTS.
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:COVERALLS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING AND SMOKING.
Supplemental Safety and Health
% VOLAT:46-47(WT). EXPLO HAZ:HF IS RELEASED DURING FIRE. EFTS OF
OVEREXP:AFTER EXPOS/PASS WITHIN 36-48 HRS. EFTS ARE NOT CUMULATIVE.
EXPOS USUALLY RESULTS FROM SMOKING TOBACCO/CIGARETTES CONTAMD W/FLU
OROCARBON DURING HNDLG/FROM BRTHG VAPS EMITTED DURING BAKING. DO
NOT EXCEED RECOMM BAKING TEMPS. BAKING (SEE ING 5)
HCC:F3
Boiling Pt:B.P. Text:172F,78C
Vapor Pres:SEE INGRED
Vapor Density:HVR/AIR
Evaporation Rate & Reference:SLOWER THAN ETHER.
Solubility in Water:SLIGHT.
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE REASONABLY FORESEEABLE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF HEAVY METALS REPORTED IN
INGREDIENTS SECTION, IF ANY. HYDROGEN FLUORIDE.
Waste Disposal Methods:DO NOT ALLOW MATERIAL TO CONTAMINATE GROUND
WATER SYSTEMS. INCINERATE ABSORBED MATERIAL I/A/W FEDERAL, STATE
AND LOCAL REQUIREMENTS. DO NOT INCINERATE IN CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.