LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES: IRRITATION MAY OCCUR. SKIN:
IRRITATION MAY OCCUR IN SUSCEPTIBLE INDIVIDUALS. INHAL: IRRITATION
MAY OCCUR IN SUSCEPTIBLE INDIVIDUALS. MAY CAUSE "METAL FUME FEVER",
ESPECIALLY IF FRESHLY FORMED ZI NC OXIDE PRESENT. INGEST: MAY CAUSE
GI IRRIT. PRLNG/RPTD EXPOSURE MAY CAUSE SENSITIZATION IN
SUSCEPTIBLE INDIVIDUALS.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
Eyes: FLUSH IMMEDIATELY W/PLENTY OF WATER FOR A MINIMUM OF 15
MINUTES & GET MEDICAL ATTN. SKIN: REMOVE CONTAMINATED CLOTHING.
WASH SKIN W/PLENTY OF SOAP & WATER. LAUNDER CLOTHES BEFORE REUSE.
IF IRRIT ATION PERSISTS GET MEDICAL ATTN. INHAL:REMOVE TO FRESH
AIR. IF DISCOMFORT PRESENT, GET MEDICAL ATTN. INGEST: GET MEDICAL
ATTN IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point:COMBUSTIBLE
Extinguishing Media:DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . DO NOT ALLOW POWDER TO BE DISPERSED INTO THE
AIR WHILE EXTINGUISHING.
Unusual Fire/Explosion Hazard:WHEN SUSPENDED IN AIR AS A DUST CLOUD,
THIS PROD IS A POTNTL FIRE/EXPLO HAZ. DECOMP/COMBUST PRODS MAY BE
TOX. MAY EXPLODE IN CONT W/OXIDIZING AGENTS.(SUPP DATA)
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. AVOID
INHALATION OF DUST. VENTILATE AREA.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID SKIN & EYE CONTACT. AVOID
BREATHING DUST OR VAPOR FROM HEATED PRODUCT DURING CURE.
Other Precautions:DO NOT USE NEAR SPARKS, OPEN FLAMES OR ANY OTHER
IGNITION SOURCE. DUST CLOUDS ARE A POTENTIAL FIRE & EXPLOSION
HAZARD. GROUND ALL EQUIPMENT TO PREVENT BUILDUP OF STATIC
ELECTRICITY.
Respiratory Protection:IN OUTDOOR/OPEN AREAS, W/UNRESTRICTED VENT, USE
NIOSH/MSHA APPRVD FILTER RESPIRATOR TO REMOVE SOLID AIR-BORNE
PARTICLES OF OVERSPRAY DURING SPRAY APPLICATN. IN RESTRICTED VENT
AREAS, USE NIOSH/MSHA AP PRVD RESPIRATOR I/A/W 29CFR (SUPP DATA)
Ventilation:PROVIDE SUFFICIENT VENT, IN VOL/PATTERN, TO KEEP TLV/LEL OF
HAZ INGREDS BELOW LIMITS SPECIFIED & TO REMOVE (SUPP DATA)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:CHEM WORK GOG & FULL LENGTH FSHLD.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
EXPLO HAZ: ZINC REACTS W/WATER, SOME ACIDS & BASES TO PRDCE FLAMMABLE
HYDROGEN GAS. RESP PROT: 1910.134 TO REMOVE A COMBINATION OF
PARTICULATES & VAPORS FROM HEATED PRODUCT. VENT: DECOMPOSITION
PRODUC TS DURING WELDING OR FLAME CUTTING ON SURFACES COATED W/THIS
PRODUCT.
Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH LOCAL, STATE, AND
FEDERAL REGULATIONS. DO NOT INCINERATE UNOPENED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.