LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY CAUSE DIZZ/NARCOSIS IN HIGH VAPOR
CONC. DIFF IN BRTHG. WILL CAUSE DEFATTING OF SKIN AND REDNESS. EFTS
ARE REVERSIBLE. LONG TERM EXPOS (YEARS) VAP MAY CAUSE LUNG,
LIVER/KIDNEY DMG. THE SOLVENTS LIS TED HAVE BEEN REPORTED TO AFFECT
THE CENTRAL NERVOUS SYSTEM. CHLOROCARBON (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: MATLS HAVE PRDCD SENSIT OF MYOCARDIUM
TO EPINEPHRINE IN LAB ANIMALS AND COULD HAVE A SIMILAR EFFECT IN
HUMANS. ADRENOMIMETICS (E.G., EPINEPHRINE) MAY BE CONTRAINDICATED
EXCEPT FOR LIFE-SUSTA INING USES IN HUMANS ACUTELY OR CHRONICALLY
EXPOSED TO CHLOROCARBONS .
Medical Cond Aggravated by Exposure:HEART DISEASE, RESPIRATORY
DISORDERS.
======================= First Aid Measures =======================
First Aid:GIVE OXYGEN - DO NOT INDUCE VOMITING - GASTRIC LAVAGE- WASH
EYES AND SKIN WITH WATER FOR AT LEAST 15 MINUTES.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:-40F,-40C
Lower Limits:1.8
Upper Limits:12.0
Extinguishing Media:USE WATER FOG, DRY CHEMICAL OR CARBON DIOXIDE.
Fire Fighting Procedures:AEROSOL CANS MAY RUPTURE WHEN HEATED. WEAR
NIOSH/MSHA APPROVED PRESSURE DEMAND SCBA AND FULL PROTECTIVE
EQUIPMENT
Unusual Fire/Explosion Hazard:HEATED CANS MAY BURST. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE
Spill Release Procedures:USE ABSORBENT SWEEPING COMPOUND TO SOAK UP
MATERIAL. PUT INTO CONTAINER. DISPOSE AS HAZARDOUS WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS, OR OPEN
FLAME. STORE AT TEMPERATURES BELOW 120F.
Other Precautions:WHEN USING > 1 HALF CAN CONTINUOUSLY/ > 1 CAN
CONSECUTIVELY,USE NIOSH APPROVED RESP.NO SMOKING IN AREA OF USE.DO
NOT USE IN GENL VICINITY OF ARC WELDING,OPEN FLAMES/HOT SURF.HEAT
&/UV RADIATION MAY CA USE FORMATION OF HCL &/PHOSGENE.
Respiratory Protection:WEAR NIOSH/MSHA APPROVED SCBA IF TLV LIMIT
EXCEEDED.
Ventilation:LOCAL EXHAUST
Protective Gloves:NONE REQUIRED IF SPRAYING.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:LONG SLEEVE AND LONG PANTS.
Work Hygienic Practices:DO NOT SMOKE WHILE USING. WASH HANDS AFTER USE.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
THE ABOVE SOLVENTS ARE INCOMPATIBLE WITH STRONG OXIDIZERS AND ACTIVE
METALS.
Stability Condition to Avoid:HIGH TEMPERATURES.
Hazardous Decomposition Products:IN A FIRE, WILL DECOMPOSE TO HALOGEN
ACIDS, PHOSGENE, CARBON DIOXIDE AND WATER.
Waste Disposal Methods:DISPOSE AS HAZARDOUS WASTE IN ACCORDANCE WITH
EPA, RCRA. DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE, AND LOCAL
REGULATIONS .
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.