LD50 LC50 Mixture:LD50:(ORAL RAT) >5 G/KG
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES:CAUSES MODERATE TO SEVERE
IRRIT. SKIN:MODERATELY IRRITATING TO SKIN. INHAL:CHLORINATED
TRISODIUM PHOSPHATE DUST/MIST MAY CAUSE IRRIT TO UPPER RESPIRATORY
TRACT. PRLNGD INHALATION MAY CAUSE LUNG IRRIT. INGEST:MAY CAUSE
NAUSEA, VOMITING, CRAMPS & DIARRHEA IF SWALLOWED. PRACTICALLY
NON-TOX (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:THROUGH INGESTION. CHRONIC: NONE
KNOWN.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:EYE:IN CASE OF CONTACT W/CONCENTRATED PROD, IMMED FLUSH
W/PLENTY OF WATER FOR AT LEAST 15 MINS. CALL MD. SKIN:IMMED FLUSH
W/PLENTY OF WATER FOR AT LEAST 15 MINS. IF IRRIT DEVELOPS, SEEK MD.
INHAL:IF D UST IS INHALED, REMOVE TO FRESH AIR. IFIRRIT PERSISTS,
SEEK MD. INGEST:IF SWALLOWED, DO NOT INDUCE VOM. GIVE 1 OR 2
GLASSES OF WATER. CALL MD IMMED. NEVER GIVE ANYTHING BY MOUTH TO AN
UNCON PERSON.
===================== Fire Fighting Measures =====================
Extinguishing Media:PRODUCT IS NOT FLAMMABLE. USE MEDIA APPROPRIATE FOR
THE PRIMARY SOURCE OF FIRE.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . EXERCISE CAUTION WHEN FIGHTING ANY CHEMICAL
FIRE.
Unusual Fire/Explosion Hazard:IF INVOLVED IN A FIRE, TOXIC CHLORINE
FUMES MAY BE EMITTED.
Spill Release Procedures:SWEEP UP SPILL & PLACE IN A D.O.T. APPROVED
CONTAINER FOR DISPOSAL. WASH RESIDUE TO SANITARY SEWER W/WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A DRY PLACE. KEEP CONTAINER
CLOSED.
Other Precautions:AVOID CONTACT W/EYES, SKIN & CLOTHING. AVOID
BREATHING DUST.
pH:SUPDAT
Solubility in Water:COMPLETE
Appearance and Odor:WHITE GRANULAR SOLID; CHLORINE ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACIDS.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:CONTACT W/ACIDS OR EXPOSURE TO EXTREME
HEAT MAY CAUSE LIBERATION OF CHLORINE GAS.
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE W/LOCAL, STATE &
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.