Search   
MSDS  : BLITZ SURGICAL INSTRUMENT CLEANER AND LUBRI
CAS  : 76-13-1
64742-65-0
124-38-9
NAME  : 1,1,2-trichloro-1,2,2-trifluoroethane (freon 113) (sara
mineral oil/solvent-dewaxed heavy parafinic petroleum
carbon dioxide
===================== Product Identification =====================

MSDS NAME:BLITZ SURGICAL INSTRUMENT CLEANER AND LUBRI
NIIN:01-073-5955
MSDS Number: BNMRX
=== Responsible Party ===
Company:MINNESOTA MINING AND MFG CO., MEDICAL DIV.
Address:3M CENTER BLDG 275-4E-01
City:ST PAUL
State:MN
ZIP:55144-1000
Country:US
Info Phone Num:612-733-1110
Emergency Phone Num:612-733-1110
CAGE:69892
=== Contractor Identification ===
Company:MINNESOTA MINING AND MFG CO MEDICAL DIV
Address:3M CENTER BLDG 275-4E-01
Box:City:ST PAUL
State:MN
ZIP:55144-1000
Country:US
Phone:800-228-3957
CAGE:69892
Company:RENOW INC.
Address:883 NORFOLK SQUARE
Box:City:NORFOLK
State:VA
ZIP:23502
Country:US
Phone:804-466-8008
CAGE:3X545

============= Composition/Information on Ingredients =============

Name:1,1,2-TRICHLORO-1,2,2-TRIFLUOROETHANE (FREON 113) (SARA
III)
CAS:76-13-1
RTECS #:KJ4000000
Fraction by Wt: 77.9%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1000PPM/1250STEL
ACGIH TLV:1000PPM/1250STEL9192
Ozone Depleting Chemical:1

Name:MINERAL OIL/SOLVENT-DEWAXED HEAVY PARAFINIC PETROLEUM
DISTILLATES
CAS:64742-65-0
RTECS #:PY8038500
Fraction by Wt: 19.5%
Other REC Limits:NONE SPECIFIED
OSHA PEL:5 MG/M3 AS OIL MIST
ACGIH TLV:5 MG/M3 AS OIL MIST

Name:CARBON DIOXIDE
CAS:124-38-9
RTECS #:FF6400000
Fraction by Wt: 2.6%
Other REC Limits:NONE SPECIFIED
OSHA PEL:10000PPM/30000STEL
ACGIH TLV:5000PPM/30000STEL;92

===================== Hazards Identification =====================

LD50 LC50 Mixture:LD50 ORAL RAT-43G/KG FOR FREON TF
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE:MILD IRRITATION,REDNESS,SWELLING,
PAIN & TEARING.SKIN:PROLONGED/REPEATED CONTACT CAN CAUSE MILD
IRRITATION, REDNESS,SWELLING & ITCHING.INHALED:CAN CAUSE CNS
DEPRESSION,HEADACHE, DIZZINESS,DROWSINE SS &
UNCONSCIOUSNESS.ORAL:ASPIRATION PNEUMONITIS, COUGHING,WHEEZING &
MAY BE DEATH.CHRONIC-MAY CAUSE LIVER,LUNG DAMAGE
Explanation of Carcinogenicity:THERE ARE NO INGREDIENTS ABOVE 0.1%
WHICH ARE IDENTIFIED AS CARCINOGENS BY NTP,IARC OR OSHA.
Effects of Overexposure:MILD EYE IRRITATION, REDNESS, SWELLING, PAIN &
TEARING. PROLONGED/REPEATED SKIN CONTACT CAN CAUSE MILD IRRITATION,
REDNESS, SWELLING & ITCHING. INHALATION CAN CAUSE CNS DEPRESSION,
HEADACHE, DIZZINESS , DROWSINESS & UNCONSCIOUSNESS. ASPIRATION
PNEUMONITIS, COUGHING & WHEEZING IF INGESTED. MAY BE FATAL.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING SKIN
DISORDERS OR IMPAIRED LIVER, KIDNEY OR RESPIRATORY FUNCTION MAY BE
MORE SUSCEPTIBLE TO THE EFFECTS OF THE SUBSTANCE.

======================= First Aid Measures =======================

First Aid:GET MEDICAL ATTENTION IF SYMPTOMS PERSIST. SKIN:WASH SKIN
WITH SOAP & WATER. EYE:FLUSH WITH WATER FOR 15 MINUTES, HOLDING
EYELIDS OPEN. INHALED:REMOVE TO FRESH AIR & PROVIDE OXYGEN/CPR IF
NEEDED. ORAL :DO NOT INDUCE VOMITING. GET IMMEDIATE MEDICAL
ATTENTION. IF CONSCIOUS, DRINK TWO GLASSES OF WATER.

===================== Fire Fighting Measures =====================

Flash Point:AEROSOL
Lower Limits:0.6
Upper Limits:7
Extinguishing Media:CO2, FOAM/DRY CHEMICAL. WATER SPRAY MAY BE USED TO
KEEP FIRE EXPOSED CONTAINERS COOL & FLUSH SPILLS AWAY.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS IN + PRESSURE MODE.
COOL FIRE EXPOSED CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:HYDROGEN CHLORIDE, HYDROGEN FLUORIDE AND
PHOSGENE

================== Accidental Release Measures ==================

Spill Release Procedures:WEAR PROTECTIVE EQUIPMENTS. VENTILATE AREA.
STOP LEAK. SOAK UP SPILLS WITH CLAY/SAND. TRANSFER TO PROPER
CONTAINER FOR DISPOSAL.
Neutralizing Agent:NONE

====================== Handling and Storage ======================

Handling and Storage Precautions:STORAGE- STORE IN COOL PLACE. KEEP
AWAY FROM HEAT, FLAME & STRONG OXIDANTS.
Other Precautions:CAUTION! PRESSURIZED CONTAINER. EMPTY CONTAINER MAY
CONTAIN PRODUCT RESIDUE WHICH COULD INCLUDE FLAMMABLE/EXPLOSIVE
VAPORS. DO NOT WELD, HEAT OR DRILL CONTAINER. RESIDUE MAY IGNITE
WITH EXPLOSIVE VIOL ENCE IF HEATED SUFFICIENTLY.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NON REQUIRED UNDER NORMAL CONDITIONS. IF HIGH
VAPOR OR MIST PRESENT, USE NIOSH-APPROVED RESPIRATOR FOR ORGANIC
VAPORS AND MISTS.
Ventilation:MECHANICAL (GENERAL AND/OR LOCAL EXHAUST, EXPLOSION-PROOF)
VENTILATION
Protective Gloves:RUBBER
Eye Protection:SAFETY GOGGLES/FACE SHIELD
Other Protective Equipment:EYE WASH STATION AND SAFETY SHOWER.
INDUSTRIAL-TYPE WORK CLOTHING AND APRON AS REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING OR
FOOTWEAR.
Supplemental Safety and Health
CHANGE MADE ON 94004 IS FOR A WALL-2-WALL TSR,LISTING RENOW(A
DISTRIBUTOR).HMIS SPOKE TO TOM MCARTIS OF RENOW ON 94004.HE STATES
THAT THEY DISTRIBUTE THE 3M PRODUCT,BLITZ SURGICAL CLEANER.

================== Physical/Chemical Properties ==================

HCC:V2
Boiling Pt:>315.6C, 600.F
Vapor Pres:0.1 - 5.6
Vapor Density:>1
Evaporation Rate & Reference:>1 (ETHER = 1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:LIQUID, AMBER COLOR
Percent Volatiles by Volume:81

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:HEAT, FIRE
Hazardous Decomposition Products:HYDROGEN CHLORIDE, HYDROGEN FLUORIDE
AND PHOSGENE

==================== Disposal Considerations ====================

Waste Disposal Methods:INCINERATE IN AN INDUSTRIAL OR COMMERCIAL
FACILITY. DO NOT PUNCTURE OR BURN CANS IN A HOUSEHOLD INCINERATOR.
COMBUSTION PRODUCT WILL INCLUDE HF AND HCL. OBSERVE ALL APPLICABLE
LOCAL, STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
ASBESTOS FILLED SPIRAL WOUND GASKET 12001-29-5
AMYL ACETATE,A 5390 628-63-7
BOOK MATCHES 7723-14-0
CRESOL RED INDICATOR SOLUTION 67-63-0
1733-12-6
7732-18-5
USN PART "A" PACKING 12001-29-5
USN PART "B" PACKING 7782-42-5
INCONEL 7440-47-3
7439-89-6
7439-96-5
7440-02-0
7440-32-6
MIL-C-11796 CLASS III
5SP1A CRT ELECTRON TUBE
GENETRON 113 76-13-1
LUBRICATING OIL,PROPELLER
GAS DIAL THERMOMETER
146 4114 KODAK RAPID FIXER, PART A 7732-18-5
7783-18-8
126-96-5
10043-35-3
64-19-7
ISOPROPYL ALCOHOL 99% 67-63-0
PERMA-SLICK G (10-117) 1317-33-5
12141-20-7
1309-64-4
1330-20-7
78-93-3
146 6432 KODAK COLOR DEVELOPING AGENT,CD-3 15646-71-3
KODAK RAPID FIXER,PART A;CAT NO 146 4106 7732-18-5
7783-18-8
126-96-5
10043-35-3
64-19-7
KODAK FLEXICOLOR DEVELOPER, PART C 7732-18-5
25646-77-9
25646-77-9
298-14-6
140-01-2
183 2013, KODAK EKTAPRINT 2 DEVELOPER REPLE 7732-18-5
584-08-7
100-51-6
111-46-6
102-71-6
25646-71-3
192 7698 FLEXICOLOR DEVELOPER,PART D (WORKI 7732-18-5
25646-77-9
584-08-7
298-14-6
140-01-2
BLITZ SURGICAL INSTRUMENT CLEANER AND LUBRI 76-13-1
64742-65-0
124-38-9
180 5886, KODAK EKTAPRINT 2 DEVELOPER REPLE 7732-18-5
584-08-7
100-51-6
111-46-6
102-71-6
25646-71-3
DETECTOR SPOT STAR SHAPED
AMPOULE 4 POSITION 11 (DOUBLE; GREEN LIQUID 7758-98-7
107-21-1
7732-18-5
AMPOULE 3 POSITION 2 (CLEAR LIQUID BROWN TU 77-09-8
67-56-1
CLEAR LIQUID WITH BLACK TUBING AMPOULE 3 AL 67-56-1
7732-18-5
HEATER PAD POSITION #11 7447-39-4
107-21-1
7732-18-5
PELLET (TAB1) POSITION #7 1314-13-2
13463-67-7
AMPOULE 5 POSITION #6 (PINK LIQUID) 8030-30-6
AMPOULE 3 POSITION 5 (CLEAR LIQUID/ORANGE P 1314-13-2
13463-67-7
112945-52-5
71011-26-2
57-11-4
AMPOULE 3 (CLEAR LIQUID BLACK TUBING) 67-56-1
7732-18-5
AMPOULE 3 POSITION 2 (CLEAR LIQUID BLUE TUB 67-56-1
CLEAR LIQUID WITH RED TUBING AMPOULE 5 PSN 584-08-7
7732-18-5
802300 EMERGENCY ESCAPE BREATHING DEVICE 7775-09-9
7778-74-7
1304-29-6
1310-65-2
186 5278, KODAK EKTAPRINT 2 DEVELOPER REPLE 7732-18-5
584-08-7
100-51-6
111-46-6
25646-71-3
LUPERSOL DDM-9 1338-23-4
107-41-5
131-11-3
7722-84-1
78-93-3
MEAT BRANDING
NIT 2,SHEPCO 58 64-19-7
85-56-6
7732-18-5
1922 A CONCISE ENAMEL BOND SYSTEM RESIN A 109-16-0
1565-94-2
3077-12-1
2440-22-4
1922 B CONCISE ENAMEL BOND SYSTEM RESIN B 1565-94-2
109-16-0
94-36-0
128-37-0
1923 CONCISE ETCHING LIQUID 7732-18-5
7664-38-2
121 4675 EKTAPRINT L DEVELOPER 7439-89-6
63149-52-0
1333-86-4
CAF 9 12001-29-5
DOD-L-24651 TYPE II
FERRIC CHLORIDE, SOLID, ANHYDROUS 7705-08-0
KODAK INDUSTREX FIXER & REPLENISHER, PART A 7783-18-8
7732-18-5
126-96-5
64-19-7
7757-83-7
KODAK PMT II DELETIION FLUID; CAT 348 8715 7732-18-5
7681-11-0
64-19-7
96-48-0
IMPORTER'S YUASA BATTERY (AMERICA), INC 7664-93-9
3M BRAND 1600 CHEN-PAC MICROFILM DEVELOPER 7732-18-5
7757-83-7
584-08-7
123-31-9
3M BRAND 1600 CHEN-PAC MICROFILM FIXER 7732-18-5
7783-18-8
10192-30-0

Free MSDS Search ( Providing 250,000+ Material Properties )