===================== Product Identification =====================
MSDS NAME:IMPORTER'S YUASA BATTERY (AMERICA), INC
NIIN:01-293-7749
MSDS Number: BNMTF
=== Responsible Party ===
Company:YUASA BATTERY AMERICA INC
Address:9728 ALBURTIS AVE
City:SANTA FE SPRINGS
State:CA
ZIP:90670
Country:US
Info Phone Num:213-949-4266 OR 800-423-4667
Emergency Phone Num:213-949-4266 OR 800-423-4667
CAGE:77280
=== Contractor Identification ===
Company:ARJAY ELECTRONICS CORP
Address:525 W CHESTER PIKE SUITE 314
Box:City:HAVERTOWN
State:PA
ZIP:19083-4539
Country:US
Phone:215-449-3600
CAGE:64812
Company:YUASA-EXIDE INC
Address:2366 BERNVILLE ROAD
Box:14145
City:READING
State:PA
ZIP:19612-4145
Country:US
Phone:610-208-1975
CAGE:77280
============= Composition/Information on Ingredients =============
Name:SULFURIC ACID (SARA III)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 32-40%
Other REC Limits:NONE SPECIFIED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL RAT LD50 NONE STATED
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:CONTACT TO SENSITIVE SKIN OR PROLONGED
CONTACT WITH NORMAL SKIN MAY CAUSE MILD IRRITATION. CONTACT MADE
WITH EYES MAY CAUSE CORNEA DAMAGE. NO CHRONIC EFFECTS ARE STATED BY
THE MANUFACTURER.
Effects of Overexposure:CONTACT TO SENSITIVE SKIN OR PROLONGED CONTACT
WITH NORMAL SKIN MAY CAUSE MILD IRRITATION.
Medical Cond Aggravated by Exposure:IRRITATION, BURNS, ULCERATION.
======================= First Aid Measures =======================
First Aid:SKIN: FLUSH AFFECTED AREA WITH LARGE AMOUNTS OF COOL CLEAN
WATER. IF REDNESS OR BLISTERING OCCURS, CONSULT A PHYSICIAN. EYES:
FLUSH WITH LARGE AMOUNTS OF COOL WATER FOR AT LEAST 15 MINUTES.
CONSULT A PHYSICIAN. INGESTION: DRINK LARGE AMOUNTS OF WATER.
CONSULT A PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point:NON-COMBUSTIBLE
Extinguishing Media:DRY CHEMICAL, CARBON DIOXIDE, WATER FOG, WATER
Fire Fighting Procedures:SULFURIC ACID FUME, SULFUR DIOXIDE GAS OR
CARBON MONOXIDE MAY BE RELEASED WHEN ACID DECOMPOSES. WEAR
NIOSH-APPROVED SELF CONTAINED BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:WATER APPLIED TO SULFURIC ACID GENERATES
HEAT AND CAUSES ACID TO SPATTER. SULFURIC ACID REACTS VIOLENTLY
WITH METALS, NITRATES, CHLORATES, AND ORGANIC MATERIALS
================== Accidental Release Measures ==================
Spill Release Procedures:CLEAN AREA WITH PLAIN WATER. WASH HANDS AND
OTHER SKIN AREAS WITH COOL WATER AND MILD SOAP. DO NOT TOUCH EYES.
Neutralizing Agent:SODIUM CARBONATE OR QUICKLIME (CALCIUM OXIDE).
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID DAMAGE TO TERMINALS AND SEALS,
DO NOT DOUBLE-STACK INDUSTRIAL BATTERIES. WEAR APPROPRIATE
PROTECTIVE CLOTHING.
Other Precautions:STORE LEAD/ACID BATTERIES WITH ADEQUATE VENTILATION.
AVOID PROLONGED CONTACT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NONE REQUIRED UNDER NORMAL CONDITIONS.
Ventilation:GOOD ROOM VENTILATION IS REQUIRED.
Protective Gloves:ACID RESISTANT RUBBER GLOVES
Eye Protection:SAFETY GLASSES WITH SIDE SHIELDS.
Other Protective Equipment:LONG SLEEVED SHIRTS, LONG PANTS, CLOSED
SHOES.
Work Hygienic Practices:FOLLOWING CONTACT, WASH HANDS THOROUGHLY BEFORE
EATING, DRINKING OR SMOKING.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
HCC:C1
Boiling Pt:=95.C, 203.F
Melt/Freeze Pt:=-70.C, -94.F
Vapor Pres:10 @ 18F
Vapor Density:>1
Spec Gravity:1.245 TO 1.295
Evaporation Rate & Reference:NOT RELEVANT
Solubility in Water:SULFURIC ACID ONLY
Appearance and Odor:6.0 VOLT, LEAD ACID ELECTROLYTE STORAGE BATTERY.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
COMBUSTIBLES, AND ORGANIC MATERIALS SUCH AS: CHLORATES, CARBIDES,
FULMINATES, PICRATES, PEROXIDES, NITRATES, CYANIDES.
Stability Condition to Avoid:BREAKING OR CRUSHING THE BATTERY CASE.
Hazardous Decomposition Products:SULFUR TRIOXIDE, CARBON MONOXIDE,
SULFURIC ACID FUMES, AND SULFUR DIOXIDE. TOXIC GASES MAY BE
RELEASED BY REACTIONS.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONSULT YOUR LOCAL ENVIRONMENTAL OFFICER.
NEUTRALIZE THE ELECTROLYTE, COLLECT THE RESIDUE AND PLACE IN A DRUM
OR SUITABLE CONTAINER. DISPOSE OF AS A HAZARDOUS WASTE. DO NOT
FLUSH LEAD CONTAMINATED ACI D TO SEWER. DO NOT INCINERATE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|