Search   
MSDS  : TEMPLATE EMULSIONS TYPE RC & WOS
CAS  : 7783-96-2
10108-64-2
NAME  : gelatin
silver halides to also include 7783-90-6 and 7785-23-1
cadmium chloride (sara iii)
non hazardous ients
===================== Product Identification =====================

MSDS NAME:TEMPLATE EMULSIONS TYPE RC & WOS
NIIN:00-472-8786
MSDS Number: BPXDR
=== Responsible Party ===
Company:ANITEC IMAGE CORP
Address:40 CHARLES ST
Box:4444
City:BINGHAMTON
State:NY
ZIP:13902
Country:US
Info Phone Num:800-234-7707
Emergency Phone Num:607-774-3333
CAGE:61263
=== Contractor Identification ===
Company:ANITEC IMAGE CORP
Address:40 CHARLES ST
Box:4444
City:BINGHAMTON
State:NY
ZIP:13902
Country:US
Phone:607-774-3333
CAGE:61263

============= Composition/Information on Ingredients =============

Name:GELATIN
Fraction by Wt: 10% %
Other REC Limits:NONE RECOMMENDED

Name:SILVER HALIDES TO ALSO INCLUDE 7783-90-6 AND 7785-23-1
CAS:7783-96-2
Fraction by Wt: 10% %
Other REC Limits:0.1 MG/M3

Name:CADMIUM CHLORIDE (SARA III)
CAS:10108-64-2
RTECS #:EV0175000
Fraction by Wt: TRACE
Other REC Limits:NONE RECOMMENDED
OSHA PEL:SEE 1910.1027
ACGIH TLV:0.05 MG(CD)/M3; 9293
EPA Rpt Qty:10 LBS
DOT Rpt Qty:10 LBS

Name:NON HAZARDOUS INGREDIENTS
Fraction by Wt: BALANCE
Other REC Limits:NONE RECOMMENDED

===================== Hazards Identification =====================

LD50 LC50 Mixture:NOT SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:THIS PRODUCT CONTAINS SMALL AMOUNTS OF
A CADMIUM SALT AND MAY CAUSE LOCALIZED IRRITATION. CADMIUM HAS BEEN
DETERMINED TO BE A CARCINOGEN BASED ON SUBCATANEOUS ANIMAL LAB
STUDIES. CARE SHOULD BE TAKEN TO MINIMIZE EXPOSURE TO SOLUTIONS TO
WHICH THIS PRODUCT HAS BEEN PROCESSED.
Explanation of Carcinogenicity:CADMIUM HAS BEEN DETERMINED TO BE A
CARCINOGEN BY IARC PER MANUFACTURER.
Effects of Overexposure:SKIN IRRITATION, EYE IRRITATION, UPPER
RESPIRATORY TRACT IRRITATION.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:REMOVE FROM SOURCE OF EXPOSURE. WASH AFFECTED AREAS
THOROUGHLY. IF IRRITATION OR OTHER CONDITIONS PERSIST, CONSULT A
PHYSICIAN.

===================== Fire Fighting Measures =====================

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:WATER MIST, ALCOHOL FOAM, CARBON DIOXIDE, DRY
CHEMICAL
Fire Fighting Procedures:AVOID BREATHING COMBUSTIBLE FUMES
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.

================== Accidental Release Measures ==================

Spill Release Procedures:DISPOSE OF MATERIALS AS NOTED BELOW. UNEXPOSED
FILM MAY BE REPACKAGED FOR FUTURE USE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

====================== Handling and Storage ======================

Handling and Storage Precautions:STORE IN COOL, DRY PLACE, AWAY FROM
HEAT, RADIATION OR LIGHT SOURCES.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:NOT NORMALLY REQUIRED.
Ventilation:NONE SPECIFIED BY MANUFACTURER.
Protective Gloves:DISPOSABLE COTTON GLOVES
Eye Protection:NOT NORMALLY REQUIRED
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING FILM AND/OR FOLLOWING
EXPOSURE TO FILM PROCESSING SOLUTIONS.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

================== Physical/Chemical Properties ==================

HCC:N1
Boiling Pt:B.P. Text:NOT GIVEN
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:NEGLIGIBLE
Vapor Density:NEGLIGIBLE
Spec Gravity:NOT GIVEN
Evaporation Rate & Reference:NEGLIGIBLE
Solubility in Water:INSOLUBLE
Appearance and Odor:GREY GEL WITH NO DISTINGUISHING ODOR
Percent Volatiles by Volume:NIL

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
DO NOT IMMERSE IN WATER OR CHEMICALS PRIOR TO PROCESSING.
Stability Condition to Avoid:AVOID EXPOSURE TO HEAT, LIGHT AND OTHER
RADIATION SOURCES EXCEPT AS NECESSARY TO PROCESS.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.

==================== Disposal Considerations ====================

Waste Disposal Methods:DISPOSAL OF FILM AND FILM PROCESSING SOLUTIONS
SHOULD BE MADE IN CONFORMANCE WITH APPLICABLE LOCAL, STATE AND
FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
SELECTRON CADMIUM ACID SPS 5050 1306-19-0
7664-93-9
QUICKSILVER GEAR LUBE-SUPER DUTY PREMIUM (S 64741-88-4
1554; 421-77A; PHOTO PRINT FIXER & REPLENIS 7783-18-8
7631-90-5
64-19-7
SODIUM METABISULFITE 7681-57-4
MITC-FUME 556-61-6
DARACLEAN 282 112-34-5
DARACLEAN 282, CLEANING COMPOUND 59157-25-0
HURRI-SAFE SPECIAL FORMULA 111-76-2
HURRI-SAFE SPECIAL FORMULA 111-76-2
METHYL PURPLE INDICATOR CODE 297 67-63-0
CONDUCTIVITY STD 2875 MHOS CODE 347
BATTERY, TITAN 12 VOLT MS 35000-3 7439-92-1
7440-36-0
7440-38-2
7440-31-5
7664-93-9
TECHALLOY 7440-02-0
7439-89-6
7440-47-3
7439-98-7
7439-96-5
7440-21-3
7440-03-1
7440-50-8
7429-90-5
7440-32-6
7440-62-2
7440-33-7
SEALED LEAD-ACID BATTERY 7664-93-9
7439-92-1
7446-14-2
NITROUS PLUS 10024-97-2
7446-09-5
NITROUS PLUS 10024-97-2
7446-09-5
XR AERIAL DEVELOPER REPLENISHER PART B (DA2 1310-58-3
XR AERIAL DEVELOPER REPLENISHER PART C (DA2 109-86-4
28427-24-9
123-31-9
XR AERIAL DEVELOPER STARTER (DA2113) 64-19-7
2431 AUTOMATIC X-RAY DEVELOPER/REPLENISHER PART A 7757-83-7
123-31-9
1310-58-3
2431 AUTOMATIC X-RAY DEVELOPER/REPLENISHER PART B 64-19-7
92-43-3
2431 AUTOMATIC X-RAY DEVELOPER/REPLENISHER PART C 111-30-8
FLEET HEAVY DUTY MOTOR OIL,10W-30 68649-42-3
ISOBUTYL ALCOHOL 78-83-1
ELECTROLYTE - SULFURIC ACID 7664-93-9
SUPERCHEM 556 DEVELOPER (135-206) 1310-58-3
7681-38-1
123-31-9
HYDROCHLORORIC ACID 7647-01-0
7732-18-5
CALCO PREMIUM UNLEADED GASOLINE 100-41-4
106-42-3
108-38-3
95-47-6
108-88-3
110-54-3
110-82-7
1634-04-4
71-43-2
MOLYSULFIDE 1317-33-5
60676-86-0
12001-29-5
TRIETHANOLAMINE 99 102-71-6
ISOPROPYL ALCOHOL, ANHYDROUS 67-63-0
ACACIA TECHNICAL POWDER 9000-01-5
XR AERIAL DEVELOPER REPLENISHER PART A (DA2 7757-83-7
XR AERIAL DEVELOPER REPLENISHER PART B (DA2 1310-58-3
XR AERIAL DEVELOPER/REPLENISHER PART C (DA2 109-86-4
28427-24-9
123-31-9
URALOANE 8267 8052-41-3
27236-65-3
INDUSTRIAL X-RAY INSTANT ACTIVATOR (141-001 1310-73-2
7757-83-7
TEMPLATE EMULSIONS TYPE RC & WOS 7783-96-2
10108-64-2
SOLVENT 111, GENERAL PURPOSE GRADE, INDUSTR 71-55-6
123-91-1
COMPROIL II REFRIGERANT COMPRESSOR OIL 64742-52-5
UNIVOLT 60-1830 INSULATING OIL 64742-53-6
NITROGEN 7727-37-9
HALOCARBON 22 75-71-8
BATTERY FLUID, ACID (ELECTROLYTE) 7664-93-9
7732-18-5
STABILIZER CT.(FOR USE WITH P-6 ACTIVATOR)( 1762-95-4
7681-57-4
64-19-7
ROSIN FLUX CORED SOLDER WIRES, WRP, WRMAP, 7440-31-5
7439-92-1
7440-36-0
7440-69-9
7440-22-4
7440-74-6
8050-09-7
C AND H AERIAL FIXER PART A.(DA2121) 7783-18-8
7757-83-7
64-19-7
DA 2121 C & H AERIAL FIXER HARDENER,PART B 10043-01-3
MC FIXER PART A.(M5123) 7783-18-8
7757-83-7
64-19-7

Free MSDS Search ( Providing 250,000+ Material Properties )