LD50 LC50 Mixture:ORAL LD50 (RAT) IS 31000 MG/KG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE: MATERIAL IS ESSENTIALLY
NON-HAZARDOUS AND NON-IRRITATING BY ALL ROUTES OF EXPOSURE.
CHRONIC: IARC LAB ANIMAL TESTS HAVE SHOWN MATERIAL TO SHOW SOME
MUTAGENIC, REPRODUCTIVE, AND CARCINOGENIC PRO PERTIES.
Explanation of Carcinogenicity:IARC LAB TESTS ON ANIMALS SHOW SOME
INDICATIONS OF CARCINOGENICITY.
Effects of Overexposure:NONE UNDER NORMAL CONDITIONS OF USE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGESTION: INDUCE VOMITING BY GIVING WATER AND STICKING
FINGER DOWN THROAT. GET MEDICAL ATTENTION. INHALATION: MOVE TO
FRESH AIR. IF BREATHING STOPPED, GIVE ARTIFICIAL RESPIRATION. SEE
DOCTOR. EYES: F LUSH WITH LOTS OF WATER FOR 15 MINUTES.SEE DOCTOR.
SKIN: WASH WITH SOAP AND WATER. IF IRRITATION PERSISTS, SEE DOCTOR.
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:420F,216C
Lower Limits:0.3
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, ALCOHOL FOAM, WATER
SPRAY
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
BUNKER GEAR. USE WATER SPRAY TO COOL FIRE EXPOSED CONTAINERS.
Unusual Fire/Explosion Hazard:FOAM AND WATER CAN CAUSE FROTHING.
MATERIAL CREATES A SPECIAL HAZARD BECAUSE IT FLOATS ON WATER.
Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. WEAR PROPER
PROTECTIVE CLOTHES. CONTAIN SPILL. ABSORB WITH INERT MATERIAL.
AVOID RUN-OFF INTO SEWERS OR WATERWAYS. IF GOES INTO INTO WATERWAY
OR SEWER CALL NATIONAL RESPONSE CENTER: 800-424-8802.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM SPARKS AND FLAME. KEEP
CONTAINERS CLOSED. USE ONLY DOT APPROVED CONTAINERS. WHEN
TRANSFERRING; USE GOOD GROUNDING PROCEDURES.
Other Precautions:AVOID CONTACT WITH SKIN, EYES, AND CLOTHING. AVOID
BREATHING MIST.
Respiratory Protection:USE FULL-FACED NIOSH/MSHA APPROVED RESPIRATOR
WITH ORGANIC VAPOR CARTRIDGE OR SCBA AS APPROPRIATE. USE IN
ACCORDANCE WITH 29CFR 1910.134.
Ventilation:LOCAL EXHAUST RECOMMENDED TO MAINTAIN EXPOSURES BELOW
REGULATORY LIMITS.
Protective Gloves:NEOPRENE OR RUBBER
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES
Other Protective Equipment:IF SPILLS LIKELY; IMPERVIOUS BODY COVERING
AND BOOTS. EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
HCC:N1
Boiling Pt:B.P. Text:446F,230C
Vapor Pres:1.2 MM HG
Vapor Density:13.5
Spec Gravity:0.9861(WATER=1)
Solubility in Water:SLIGHT
Appearance and Odor:CLEAR, COLORLESS, MOBILE LIQUID WITH MILD ODOR
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:FLAME
Hazardous Decomposition Products:CARBON MONOXIDE
Waste Disposal Methods:THIS PRODUCT WHEN SPILLED OR WASTE IS A
HAZARDOUS WASTE AS DEFINED BY RCRA (40CFR261). PREFERRED METHOD IS
INCINERATION OR BIOLOGICAL TREATMENT AT LICENSED FACILITY. DISPOSE
OF IN ACCORDANCE WITH LOCA L, STATE AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.