Spill Release Procedures:VENTILATE AREA, ESPECIALLY LOW PLACES WHERE
HEAVY VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE CONTAINERS IN A CLEAN, DRY AREA.
DO NOT HEAT ABOVE 125F,52C. NO SMOKING IN AREA OF USE. DO NOT
BREATHE VAPORS.
Other Precautions:DO NOT USE IN THE GENERAL VICINITY OF ARC WELDING,
OPEN FLAMES OR HOT SURFACES. HEAT &/OR UV RADIATION MAY CAUSE THE
FORMATION OF CHLORIDES, FLUORIDES OR PHOSGENE.
Respiratory Protection:NIOSH/MSHA APPRVD AIR MASK IN HIGH
CONCENTRATIONS, MFR
Ventilation:LOC EXHST WHEN LRG AMT RELEASED.GEN MECH ESPEC IN LOW
PLACES
Protective Gloves:FOR HANDLNG LIQ
Eye Protection:FOR HANDLING LIQUID
Supplemental Safety and Health
PHYSICAL DATA ELEMENTS WERE MEASURED AT 77F,25C.
Boiling Pt:B.P. Text:118F,48C
Vapor Pres:334
Vapor Density:2.9
Spec Gravity:1.57
Evaporation Rate & Reference:0.3, WATER
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS LIQUID, SLIGHT ETHEREAL ODOR
Percent Volatiles by Volume:100
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS-POWDERED AL, ZINC, BERYLLIUM
Stability Condition to Avoid:OPEN FLAMES OR HIGH TEMPERATURE
Hazardous Decomposition Products:HCL, HYDROFLUORIC ACID, POSSIBLE
PHOSGENE
Waste Disposal Methods:EVAPORATE OUTDOORS, MFR. DISPOSAL METHOD MUST BE
IN ACCORDANCE W/LOCAL,STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.