Effects of Overexposure:DO NOT TAKE INTERNALLY OR GET INTO EYES. NO
OVEREXPOSURE KNOWN FOR SKIN WHEN USED AS DIRECTED.
======================= First Aid Measures =======================
Eyes:FLUSH W/WATER AT LEAST 15 MINS. TREAT INTERNALLY AS
THOUGH TREATING FOR KEROSENE. DO NOT INDUCE VOMITING. CALL MD.
BELOW 150F,66C THERE APPEARS TO BE NO INHALATION PROBLEMS.
===================== Fire Fighting Measures =====================
Flash Point:158F,70C OC
Extinguishing Media:FOAM, CO*2 CO*2 OR DRY CHEMICAL
Fire Fighting Procedures:ABOVE 150F,66C TREAT VAPORS AS YOU WOULD
KEROSENE.
Unusual Fire/Explosion Hazard:THE FORMULA CONTAINS WATER EMULSIFIED
W/KEROSENE WHICH GREATLY REDUCES THE HAZARDS OF THE KEROSENE.
Spill Release Procedures:MATERIAL IS NOT CONSIDERED TOXIC. MAY BE
FLUSHED DOWN THE SEWER W/WATER. ALL MATERIALS ARE BIO-DEGRADEABLE.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AT ROOM TEMPERATURE. AVOID TEMPS
OVER 130F,54C.
Other Precautions:IN A FIRE SITUATION KEEP AWAY FROM HEAT OR HOT
SURFACES ABOVE 150F,66C.
Respiratory Protection:MFR STATES NONE REQUIRED FOR NORMAL STORAGE &
USE.
Ventilation:NONE, MFR.
Protective Gloves:NONE REQUIRED.
Eye Protection:NONE REQUIRED.
Supplemental Safety and Health
ADDRESS:828 FIRST AVE. E., ALBANY, OREGON 97321. EVAP RATE:N/A UP TO
130F,54C. ABOVE 130F, 54C SAME AS KEROSENE.
Boiling Pt:B.P. Text:164F,73C
Vapor Pres:1.2
Vapor Density:1.0
Spec Gravity:1.000
Evaporation Rate & Reference:SEE SUPP DATA.
Solubility in Water:MISCIBLE
Appearance and Odor:CREAMY WHITE SLIGHTLY VISCOUS LIQUID.LAVENDER ODOR
Percent Volatiles by Volume:41
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID STRONG OXIDIZERS.
Stability Condition to Avoid:TEMPS OVER 130F,54C.
Hazardous Decomposition Products:KEROSENE AT HIGH TEMPS.
Waste Disposal Methods:LANDFILL OR FLUSH DOWN SEWER W/WATER. DISPOSAL
METHOD MUST BE IN ACCORDANCE W/LOCAL, STATE & FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.