===================== Product Identification =====================
MSDS NAME:ELECTRONIC OILS 10-9400
NIIN:00N006277
MSDS Number: BCMKG
=== Responsible Party ===
Company:EXXON COMPANY,U.S.A. (DIVISION OF EXXON CORP.)
Emergency Phone Num:(DAY) 713-221-3424
CAGE:EO384
=== Contractor Identification ===
Company:EXXON COMPANY U.S.A.
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-656-5949 / 713-656-3424
CAGE:29700
Company:EXXON COMPANY,U.S.A.
Address:800 BELL ST
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-870-6000
CAGE:EO384
============= Composition/Information on Ingredients =============
Name:ADDITIVES
Name:PETROLEUM HYDROCARBONS
ACGIH TLV:5 MG/CUM
===================== Hazards Identification =====================
Effects of Overexposure:PROLONGED OR REPEATED SKIN CONTACT MAY CAUSE
MILD SKIN IRRITATION.
======================= First Aid Measures =======================
First Aid:IF INGEST DONT INDUCE VOMITING,CALL A PHYSICIAN. REMOVE
CONTAM CLOTHES & WASH SKIN W/SOAP & H*2O. IN CASE OF CONT
W/EYES,FLUSH W/H*2O AT LEAST 15 MIN OR UNTIL IRRITATION SUBSIDES.
===================== Fire Fighting Measures =====================
Flash Point:335F (COC)
Lower Limits:1%
Upper Limits:7%
Extinguishing Media:FOAM,DRY CHEMICAL CO*2,WATER SPRAY OR FOG
Fire Fighting Procedures:USE AIR-SUPPLIED RESCUE EQUIPMENT FOR ENCLOSED
AREAS.
Unusual Fire/Explosion Hazard:DO NOT STORE OR MIX W/STRONG OXIDANTS.
================== Accidental Release Measures ==================
Spill Release Procedures:RECOVER FREE LIQUID. ADD ABSORBENT TO SPILL
AREA. VENTILATE ENCLOSED SPACES. KEEP PETROLEUM PRODUCTS OUT OF
STREAMS & WATERWAYS.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS CLOSED. KEEP AWAY FROM
HEAT & OPEN FLAME.
Other Precautions:AVOID PROLONGED OR REPEATED CONTACT W/SKIN. REMOVE
CONTAMINATED CLOTHING. WASH SKIN W/SOAP & WATER AFTER CONTACT.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NORMALLY NOT NEEDED. IF NEEDED,NIOSH/MSHA
APPROVED.
Ventilation:LOCAL EXHAUST- FACE VELOCITY >60 FPM
Protective Gloves:NORM NOT NEC
Other Protective Equipment:OIL-IMPERVIOUS APRON IF NEEDED.
Supplemental Safety and Health
EMER TELEPHONE NO.: (NIGHT) 713-668-7024. THIS PROD IS NOT CLASSIFIED
AS A "HAZ MATL" IN NORM USE AS DEFINED IN U.S. DEPT OF LABOR
REGULATIONS 29 CFR PARTS 1501,1502,1503. VAP PRESS: <0.01.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:596F
Vapor Density:>10
Spec Gravity:0.855
Evaporation Rate & Reference:<0.01 (BU AC)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR PALE COLORED LIQ. MILD PETROLEUM ODOR.
Percent Volatiles by Volume:<1
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS LIKE LIQ CHLORINE & CONCENTRATED OXYGEN.
Hazardous Decomposition Products:CARBON MONOXIDE IN THE CASE OF
INCOMPLETE COMBUSTION.
==================== Disposal Considerations ====================
Waste Disposal Methods:INCINERATE ABSORBED MATERIAL. WASTE DISPOSAL
MUST BE IAW FEDERAL, STATEN & LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|