LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT: LIQUID AND MIST MAY
IRRITATE. SKIN CONTACT: NO IRRITATION IS LIKELY AFTER BRIEF CONTACT
BUT MAY BE IRRITATING AFTER PROLONGED CONTACT. INHALATION: HIGH
CONCENTRATIONS MAY CAUSE LIGHTHEADE DNESS, SHORTNESS OF BREATH AND
MAY LEADTO NARCOSIS, CARDIAC IRREGULARITIES. INGESTION: MAY CAUSE
NAUSEA.
Explanation of Carcinogenicity:THIS MATERIAL IS NOT CONSIDERED TO BE A
CARCINOGEN BY NTP, IARC OR OSHA.
Effects of Overexposure:SEE HEALTH HAZARDS
Medical Cond Aggravated by Exposure:CARDIOVASCULAR DISEASE
======================= First Aid Measures =======================
Eyes: FLUSH WITH RUNNING WATER FOR 15 MINUTES WHILE HOLDING
EYELIDS OPEN. GET MEDICAL ATTENTION IMMEDIATELY. SKIN: WASH WITH
SOAP AND WATER. REMOVE CONTAMINATED CLOTHING. GET MEDICAL ADVICE.
INHALATIO N: REMOVE TO FRESH AIR. GIVE MOUTH-TO-MOUTH RESUSCITATION
IF NOT BREATHING. GET MEDICAL ATTENTION. INGESTION: DO NOT INDUCE
VOMITING. RINSE MOUTH & DRINK LARGE AMOUNTS OF WATER. GET MEDICAL
ATTENTION.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Extinguishing Media:THIS MATERIAL IS NOT COMBUSTIBLE. USE EXTINGUISHING
MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:EXTINGUISH ALL NEARBY SOURCES OF
IGNITION. WATER WILL EXTRACT A FLAMMABLE CO-SOLVENT, ISOPROPANOL,
WHICH WILL FORM A FLAMMABLE SUPERNATANT LAYER.
Spill Release Procedures:WEAR GLOVES, GOGGLES AND RESPIRATOR. ELIMINATE
IGNITION SOURCES. DIKE TO RETAIN RUNOFF. ABSORB WITH NONCOMBUSTIBLE
SORBENT MATERIAL AND PLACE RESIDUE IN DOT-APPROVED WASTE
CONTAINERS. KEEP OUT OF SEWE RS, STORM DRAINS, SURFACE WATERS AND
SOIL.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A COOL, DRY, WELL-VENTILATED
PLACE. STORE AWAY FROM ALL OTHER CHEMICALS AND POTENTIAL SOURCES
FOR CONTAMINATION.
Other Precautions:KEEP CONTAINER TIGHTLY CLOSED WHEN NOT IN USE. DO NOT
USE PRESSURE TO EMPTY CONTAINER. DO NOT HEAT CLOSED CONTAINERS
ABOVE 125F. EMPTY CONTAINERS WILL RETAIN PRODUCT RESIDUE AND
VAPORS.
Respiratory Protection:WEAR A NIOSH/MSHA APPROVED SELF-CONTAINED
BREATHING APPARATUS IN THE PRESSURE DEMAND MODE, OR SUPPLIED-AIR
RESPIRATOR IF USE CONDITIONS GENERATE VAPORS OR MIST.
Ventilation:LOCAL AND MECHANICAL(GENERAL) EXHAUST TO PROVIDE ADEQUATE
VENTILATION.
Protective Gloves:RUBBER GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES
Other Protective Equipment:WEAR INDUSTRIAL WORK CLOTHING. USE RUBBER
APRON OR BOOTS IF NEEDED. HAVE EMERGENCY EYE WASH AND SAFETY SHOWER
AVAILABLE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING AND BEFORE
EATING, DRINKING OR SMOKING. LAUNDER CONTAMINATED CLOTHING BEFORE
REUSE.
Supplemental Safety and Health
AVOID PROLONGED OR REPEATED EXPOSURE. DO NOT GET ON SKIN OR IN EYES. DO
NOT BREATHE VAPORS OR MIST. EVAPORATION OF THIS PRODUCT WILL
EVENTUALLY PRODUCE A MIXTURE RICH IN ISOPROPANOL WHICH THEN MAY BE
FLAMMABLE.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALIS, OXIDIZING MATERIALS, WATER, AND MOIST AIR. ALSO, ALKALI OR
ALKALINE EARTH METALS, POWDERED ALUMINUM OR ZINC.
Stability Condition to Avoid:OPEN FLAMES, WELDING ARCS, OR OTHER HIGH
TEMPERATURE SOURCES WHICH MAY INDUCE THERMAL DECOMPOSITION.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
HYDROGEN CHLORIDE, CHLORINE, PHOSGENE, AND HYDROGEN FLUORIDE.
Waste Disposal Methods:DISPOSE OF CONTAMINATED PRODUCT AND MATERIALS
USED IN CLEANING UP SPILLS OR LEAKS IN A MANNER APPROVED FOR THIS
MATERIAL. CONSULT APPROPRIATE FEDERAL, STATE AND LOCAL REGULATORY
AGENCIES TO ASCERTAIN PROPER DISPOSAL PROCEDURES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.