LD50 LC50 Mixture:
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MAY RESULT IN IRRITATION &
SEVERE BURN W/ LONGER EXPOSURE.CHRONIC:NONE CURRENTLY KNOWN
Explanation of Carcinogenicity:
Effects of Overexposure:INHAL:INHAL OF FUMES MAY RESULT IN IRRIT OF
NOSE,THROAT&RESP TRACT.CONTACT W/SKIN OR EYES:CORROSIVE & CAUSE
SEVERE BURN ON SKIN OR EYE CONTACT.ABSORBED THROUGH SKIN:NOT KNOWN
AT THIS TIME,SWALLOWED:SE VERE INTERNAL IRRITATION & MAY RESULT
DAMAGE
Medical Cond Aggravated by Exposure:
======================= First Aid Measures =======================
First Aid:EYE:IMMED FLUSH EYES W/PLENTY OF H*2O FOR AT LEAST 15
MIN.CONTACT LENSES SHLD BE REMOVED IF THE INITIAL FLUSH DOESNT WASH
THEM OUT. GET MED ATTN.SKIN:IMMED FLUSH W/LG AMT OF H*2O. REMOVE
CONTAM CLOTHI NG & REWASH BEFORE REUSE.GET MED ATTN. INHAL:REMOVE
TO FRESH AIR.BREATH STOP,START CPR.KEEP PATIENT
WARM,COMFORTABLE.SEEK MED ATTN.INGEST:DONT INDUCE VOMITING.GIVE LG
ATM H*2O. CALL PHYSICIAN IMMED.
===================== Fire Fighting Measures =====================
Flash Point:NON FLAMMABLE
Extinguishing Media:H*20 SPRAY FOAM CARBON DIOXIDE DRY CHEMICAL
Fire Fighting Procedures:WEAR SCBA & OTHER PROT EQUIP.THERMAL DECOMP
MAY EMIT TOXIC FUMES OF OXIDES OF PHOSPHORUS & CHLORINE GAS
Unusual Fire/Explosion Hazard:EXPLOSIVE CONCENTRATING OF GAS MAY
ACCUMULATE IN TANK.
Spill Release Procedures:LG SPILL SHOULD BE HANDLED IMMED BY
NEUTRALIZING W/SODA ASH OR LIME. DIKE W/INERT ABSORBENT MATERIAL.
COLLECT FOR DISPOSAL.
Neutralizing Agent:SODA ASH OR LIME
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT W/EYE & SKIN. STORE IN
COOL,WELL VENTILATED AREA W/SPRINKLER SYSTEM. PROTECT AGAINST
PHYSICAL DAMAGE. DO NOT REUSE CONTAINERS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
CORROSIVE TO MOST METALS W/ EVOLUTION OF HYDROGEN GAS WHICH IS HIGHLY
EXPLOSIVE WHEN MIXED WITH AIR.
Stability Condition to Avoid:CONTACT W/METAL SUCH AS MILD STEEL & BASES
Hazardous Decomposition Products:AT HIGH TEMPERATURE MAY EMIT TOXIC
PHOSPHORUS FUMES AND CHLORINE GAS
Conditions to Avoid Polymerization:CONTACT W/ MOST METAL
Waste Disposal Methods:DISPOSE THE NEUTRALIZED MAT.IN ACCORDANCE
W/LOCAL,STATE,&FED REGS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.