===================== Product Identification =====================
MSDS NAME:FLUOROFORM
NIIN:00N048934
MSDS Number: BTYZY
=== Responsible Party ===
Company:SPECTRA GASES, INC.
Address:277 COIT ST.
City:IRVINGTON
State:NJ
ZIP:07111
Country:US
Info Phone Num:201-372-2060
Emergency Phone Num:201-483-0257
CAGE:IO739
=== Contractor Identification ===
Company:SPECTRA GASES INC
Address:277 COIT ST
Box:City:IRVINGTON
State:NJ
ZIP:07111-5000
Country:US
Phone:201-372-2060/202-484-7616
CAGE:0BZR5
Company:SPECTRA GASES, INC.
Address:277 COIT ST.
Box:City:IRVINGTON
State:NJ
ZIP:07111
Country:US
Phone:201-372-2060
CAGE:IO739
============= Composition/Information on Ingredients =============
Name:METHANE, TRIFLUORO-; (TRIFLUOROMETHANE)
CAS:75-46-7
RTECS #:PB6900000
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT:AWAY FROM HEAVILY TRAFFICKED AREAS & EMER EXISTS. DO
NOT ALLOW TEMPS WHERE CYLS ARE STORED TO EXCEED 130F.(ING 3)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 2:CYLS SHOULD BE STORED UPRIGHT & FIRMLY SECURED TO
PVNT FALLING/BEING KNOCKED OVER. FULL & EMPTY CYLS SHOULD(ING 4)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 3:BE SEGREGATED. USE "FIRST IN-FIRST CUT" INVENTORY SYS
TO PVNT FULL CYLS FROM BEING STORED FOR EXCESSIVE (ING 5)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 4:PERIODS OF TIME. HALOCARBON 23 IS NONCORR & MAY BE
USED W/ANY COMMON STRUCTURAL MATL. SILVER & COPPER (ING 6)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 5:BEARING ALLOYS CAN ACT AS CATALYSTS FOR DECOMP OF
HALOCARBON @ AT HIGH TEMPS. ALLOYS CNTNG MORE THAN 2% (ING 7)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 6:MAGNESIUM SHOULD NOT BE USED IF H*20 IS PRESENT.
COMPRESSED GAS CYLS SHOULD NOT BE REFILLED EXCEPT BY (ING 8)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 9:QUALIFIED PRDCES OF COMPRESSED GASES. SHIPMENT OF
COMPRESSED GAS CYL WHICH HAS NOT BEEN FILLED BY OWNER OR (ING 9)
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
Name:ING 8:WITH HIS WRITTEN CONSENT IS A VIOLATION OF FEDERAL
LAW (49 CFR).
RTECS #:9999999ZZ
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:HIGH CONCENTRATIONS OF
HALOCARBON-23 SO AS TO EXCLUDE AN ADEQUATE SUPPLY OF OXYGEN TO THE
LUNGS CAUSES DIZZINESS, DEEPER BREATHING DUE TO AIR HUNGER,
POSSIBLE NAUSEA AND EVENTUAL UNCONSCIOUSNESS .
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INGEST:CALL MD IMMED . EYES:IMMED FLUSH W/POTABLE WATER FOR
MIN OF 15 MINS, SEEK ASSISTANCE FROM MD . SKIN:FLUSH W/COPIOUS AMTS
OF WATER. CALL MD . INHAL:CONSCIOUS PERSONS SHOULD BE ASSISTED TO
UNCONTAMD AREA IS MOST IMPORTANT. UNCON PERSONS SHOULD BE REMOVED
TO UNCONTAMD AREA, GIVE MOUTH-TO-MOUTH RESUSCITATION & SUPP OXYGEN.
MED ASSISTANCE SHOULD BE SOUGHT IMMED. (SUPDAT)
===================== Fire Fighting Measures =====================
Extinguishing Media:NONFLAMMABLE GAS. MEDIA SUITABLE FOR SURROUNDING
FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:IF HALOCARBON-23 IS INVOLVED IN A FIRE,
IT MAY DECOMPOSE YIELDING TOXIC PRODUCTS.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE ALL PERSONNEL FROM AFFECTED AREA. USE
APPROP PROT EQUIP. IF LEAK IS IN USER'S EQUIP, BE CERTAIN TO PURGE
PIPING W/AN INERT GAS PRIOR TO ATTEMPTING REPAIRS. IF LEAK IS IN
CNTNR/CNTNR VALVE, CO NT CLOSEST SPECTRA GASES, INC. LOCATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE ONLY IN WELL-VENT AREAS. VALVE
PROT CAPS MUST REMAIN IN PLACE UNLESS CNTNR IS SECURED W/VALVE
OUTLET PIPED TO USE POINT.
Other Precautions:DO NOT DRAG, SLIDE/ROLL CYLS. USE A SUITABLE HAND
TRUCK FOR CYL MOVEMENT. USE A PRESS REDUCING REGULATOR WHEN
CONNECTING CYL TO LOWER PRESS PIPING/SYS. DO NOT HEAT CYL BY ANY
MEANS TO INCREASE DISCHAR GE RATE OF PROD FROM CYL. USE A (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:POSITIVE PRESS AIR LINE WITH NIOSH/MSHA APPROVED
MASK OR SCBA SHOULD BE AVAILABLE FOR EMERGENCY USE.
Ventilation:TO PVNT ACCUMULATION OF HIGH CONCS SO AS TO REDUCE OXYGEN
LEVEL IN AIR TO LESS THAN 18 MOLAR PERCENT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EMERGENCY EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOLUB IN WATER :BUNSEN COEFFICIENT:0.319. FIRST AID PROC:PROMPT MED
ATTN IS MANATORY IN ALL CASES OF OVEREXPOS TO HALOCARBON 23. RESCUE
PERS SHOULD BE EQUIPPED W/SCBA. OTHER PREC:CHECK VALVE/TRAP IN D
ISCHARGE LINE TO PVNT HAZ BACK FLOW INTO CYL. PROT CYLS FROM
PHYSICAL DMG. STORE IN COOL, DRY, WELL-VENT AREA (ING 2)
================== Physical/Chemical Properties ==================
HCC:T4
Boiling Pt:B.P. Text:<-116F,<-82
Vapor Pres:609 PSIA
Spec Gravity:2.38 (H*20=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:SUPP DATA
Appearance and Odor:COLORLESS, PRACTICALLY ODORLESS GAS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE SPECIFIED BY MANUFACTURER.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HYDROGEN FLUORIDE AND OTHER TOXIC
FLUORIDES.
==================== Disposal Considerations ====================
Waste Disposal Methods:CONSULT FED, STATE & LOCAL REGS:DO NOT ATTEMPT
TO DISPOSE OF WASTE/UNUSED QUANTITIES. RETURN IN SHIPPING CNTNR
PROPERLY LABELED, W/ANY VALVE OUTLET PLUGS/CAPS SECURED & VALVE
PROT CAP IN PLACE TO SPEC TRA GASES, INC. FOR PROPER DISPOSAL.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|