===================== Product Identification =====================
MSDS NAME:CAT, MIL-C-83286, GRAY, 26492
NIIN:00K001241
MSDS Number: BXWRB
=== Responsible Party ===
Company:DEFT, INC.
Address:17451 VON KARMAN AVENUE
City:IRVINE,
State:CA
ZIP:92714
Country:US
Info Phone Num:714-474-0400
Emergency Phone Num:714-474-0400
CAGE:DO188
=== Contractor Identification ===
Company:DEFT, INC.
Address:17451 VON KARMAN AVE
City:IRVINE
State:CA
ZIP:92614
Country:US
Phone:949-474-0400
CAGE:33461
Company:DEFT, INC.
Address:17451 VON KARMAN AVE
City:IRVINE
State:CA
ZIP:92714
Phone:800-424-9300
CAGE:DO188
============= Composition/Information on Ingredients =============
Name:METHYL ISOBUTYL KETONE
CAS:108-10-1
RTECS #:SA9275000
Fraction by Wt: 10%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:50 PPM
ACGIH TLV:50 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:2-ETHOXYETHYL ACETATE
CAS:111-15-9
RTECS #:KK8225000
Fraction by Wt: 5%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM
ACGIH TLV:5 PPM
Name:TOLUENE
CAS:108-88-3
RTECS #:XS5250000
Fraction by Wt: <5%
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:HOMOPOLYMER OF HEXAMETHYLENE DIISOCYANATE (HDI)
CAS:28182-81-2
RTECS #:NQ9170000
Fraction by Wt: 30%
Other REC Limits:NONE RECOMMENDED
Name:N-BUTYL ACETATE
CAS:64046-64-6
RTECS #:AF3500000
Fraction by Wt: <5%
Other REC Limits:NONE RECOMMENDED
Name:XYLENE
CAS:1330-20-7
RTECS #:ZE2190000
Fraction by Wt: <5%
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:METHYL ETHYL KETONE
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: 45%
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: VAPORS OR MISTS AT
CONCENTRATIONS ABOVE SUGGESTED TLV CAB IRRITATE THE MUCOUS
MEMBRANES IN THE RESPIRATORY TRACT CAUSING RUNNY NOSE, SORE THROAT,
COUGHING, CHEST DISCOMFORT, SHORTNESS OF BREATH & REDUCED LUNG
FUNCTION. CHRONIC: CERTAIN INDIVIDUALS WILL DEVELOP ISOCYANATE
SENSITIZATION.
Explanation of Carcinogenicity:NONE OF THE LISTED HAZARDOUS INGREDIENTS
ARE LISTED AS CARCINOGENS BY NTP, IARC MONOGRAPHS OR OSHA.
Effects of Overexposure:INHALATION-HEADACHE, DIZZINESS, STAGGERING
GAIT, CONFUNSION, UNCONSCIOUSNESS OR COMA. SKIN & EYE-MAY BE
SWELLING, REDNESS, RASH. TEARING, REDNESS & SWELLING ACCOMPANIED BY
STINGING SENSATION. INGESTIO N-VOMITING MAY CAUSE ASPIRATION OF THE
SOLVENT RESULTING IN CHEMICAL PNEUMONITIS.
Medical Cond Aggravated by Exposure:ISOCYANATE SENSITIZATION. ASTHMA.
DERMATITIS.
======================= First Aid Measures =======================
First Aid:INHALE:MOVE TO AN AREA FREE FROM RISK OF FUTHER EXPOSURE.
RESTORE BREATHING. OBTAIN MEDICAL ATTN. SKIN:REMOVE CONTAMINATED
CLOTHING. WASH AFFECTED AREAS THOROUGHLY WITH SOAP & WATER.
EYES:FLUSH WITH C LEAN, LUKEWARM WATER FOR 15 MIN, OCCASIONALLY
LIFTING EYELIDS. OBTAIN MEDICAL ATTENTION. INGEST:DO NOT INDUCE
VOMITING. DO NOT GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
OBTAIN MEDICAL ATTENTION
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:23.0F,-5.0C
Lower Limits:1.7
Upper Limits:11.5
Extinguishing Media:FOAM, ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL,
WATER FOG.
Fire Fighting Procedures:FULL FIRE FIGHTING EQUIPMENT WITH
SELF-CONTAINED BREATHING APPARATUS & FULL PROTECTIVE CLOTHING
SHOULD BE WARN BY FIRE FIGHTERS.
Unusual Fire/Explosion Hazard:KEEP CONTAINERS TIGHTLY CLOSED. ISOLATE
FROM HEAT, SPARKS, ELECTRICAL EQUIPMENT AND OPEN FLAME. CLOSED
CONTAINERS MAY EXPLODE WHEN EXPOSED TO EXTREME HEAT.
================== Accidental Release Measures ==================
Spill Release Procedures:EVACUATE ALL NONESSENTIAL PERSONNEL. REMOVE
ALL SOURCES OF IGNITION (FLAME, HOT SURFACES, SPARK SOURCES)
VENTILATE AREA. CONTAIN AND REMOVE WITH INERT ABSORBENT AND
NON-SPARKING TOOLS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN BUILDING DESIGNED TO COMPLY
WITH OSHA 1910.106. AVOID STORING NEAR HIGH TEMPERATURES, FIRE,
OPEN FLAMES & SPARK SOURCES.
Other Precautions:STORE IN TIGHTLY CLOSED CONTAINERS. STORE IN WELL
VENTILATED AREAS. KEEP CONTAINERS TIGHT & UPRIGHT TO PREVENT
LEAKAGE. PREVENT PROLONGED OR REPEATED BREATHING OF VAPORS OR SPRAY
MIST.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A RESPIRATOR THAT IS RECOMMENDED OR APPROVED FOR
USE IN ISOCYANATE CONTAINING ENVIROMENTS (AIR PURIFYING OR FRESH
AIR SUPPLIED) IS NECESSARY. OBSERVE OSHA REGULATIONS FOR RESPIRATOR
USE.
Ventilation:EXHAUST VENTILATION SUFFICIENT TO KEEP THE AIRBORNE
CONCENTRATIONS OF THE SOLVENT VAPORS OR MIST BELOW THEIR TLV'S.
Protective Gloves:NEOPRENE, RUBBER, POLYETHYLENE GLOVES.
Eye Protection:SAFETY EYEWARE W/SPLASH GUARDS.
Other Protective Equipment:USE LONG SLEEVE AND LONG LEG CLOTHING.
REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE.
Work Hygienic Practices:WASH HANDS BEFORE EATING, SMOKING OR USING
WASHROOM. SMOKE IN SMOKING AREAS ONLY.
Supplemental Safety and Health
OTHER PRECAUTIONS: PROLONGED OVEREXPOSURE CAN CAUSE AN ALLERGIC
REACTION. AVOID CONTACT WITH SKIN AND EYES. DO NOT TAKE INETRNALLY.
DO NOT HANDLE UNTIL MANUFACTURES SAFETY PRECAUTIONS HAVE BEEN READ
A ND UNDERSTOOD.
================== Physical/Chemical Properties ==================
HCC:F3
Boiling Pt:B.P. Text:175-313F
Vapor Density:>AIR
Spec Gravity:0.9
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:INSOLUBLE
Appearance and Odor:CLEAR, LIGHT AMBER COLOR WITH SOLVENT ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
WATER, AMINES, STRONG BASES, ALCOHOLS, METAL COMPOUNDS AND SURFACE
ACTIVE MATERIALS.
Stability Condition to Avoid:CONTACT WITH MOISTURE, MATERIALS WHICH
REACT WITH ISOCYANATES, AND HIGH TEMPERATURES.
Hazardous Decomposition Products:BY HIGH HEAT AND FIRE: CARBON DIOXIDE,
CARBON MONOXIDE, OXIDES OF NITROGEN, TRACES OF HCN, HDI.
==================== Disposal Considerations ====================
Waste Disposal Methods:WASTE MUST BE DISPOSED OF IN ACCORDANCE WITH
FEDERAL, STATE AND LCOAL ENVIRONMENTAL CONTROL REGULATIONS. EMPTY
CONTAINERS MUST BE HANDLED WITHCARE DUE TO PRODUCT RESIDUE AND
FLAMMABLE VAPOR. DO NOT IN CINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|
|
| ALL PAGES On Chemical Property IN THIS GROUP
| | NAME | CAS |
|
R-11
| 75-69-4 |
|
R-114
| 76-14-2 |
|
1202
| 75-61-6 |
|
R-12
| 75-71-8 |
|
1301
| 75-63-8 |
|
R-22
| 75-45-6 |
|
R-500
| 75-71-8 75-37-6 |
|
1211
| 353-59-3 |
|
R-502
| 75-45-6 76-15-3 |
|
R-11
| 75-69-4 |
|
R-11
| 75-69-4 |
|
134-A
| 811-97-2 |
|
1301
| 75-63-8 |
|
1301
| 75-63-8 |
|
1211
| 353-59-3 |
|
13R9
| 25038-59-9 25037-45-0 65181-78-4 7782-49-2 |
|
FLEETGUARD DCA 4 LIQUID COOLING CONDITIONER
| 7732-18-5 7778-77-0 7757-79-1 7632-00-0 10102-40-6 1312-76-1 |
|
BIO T PRESS BLANKET AND ROLLER WASH
| |
|
166 2659 EKTACHEM CLINICAL CHEM CALIBRATOR KIT 2-CALIBRATOR2
| |
|
166 2659 EKTACHEM CLIN CHEM CALIBRATOR KIT 2-CALIBR 2 DILUEN
| 7732-18-5 144-55-8 |
|
838 3101 THEROLINK 1000 SILICON THERMAL JOINT COMPOUND
| 118685-22-6 1314-13-2 118685-24-8 |
|
TOXAPHENE, 1X1ML, MEOH, 2000UG/ML
| 8001-35-2 67-56-1 |
|
BLACK DEVELOPER FOR DC-111, 111C, 113, 114, 142RE, 1001
| 1309-37-1 1314-13-2 1317-38-0 1317-38-0 |
|
MIL-C-83286, GRAY, 26492
| 111-15-9 78-93-3 141-78-6 |
|
CAT, MIL-C-83286, GRAY, 26492
| 108-10-1 111-15-9 108-88-3 28182-81-2 64046-64-6 1330-20-7 78-93-3 |
|
CAUSTIC SODA SOLUTION 50% REGULAR GRADE, 15216
| 1310-73-2 497-19-8 7647-14-5 7732-18-5 |
|
TURBO TOIL 68, 65605
| 64742-54-7 64742-65-0 |
|
KOOL KUT, 91620
| 127-18-4 71-55-6 124-38-9 |
|
DJC-201 NF AEROSOL, 5697
| 1717-00-6 124-38-9 |
|
PR-1154-F, PART A, (PRA 600/601)
| |
|
UNISOL, 0029
| 71-55-6 646-06-0 78-92-2 |
|
AMBERLITE-R IRA-938 RESIN, 69436
| 7732-18-5 60177-39-1 |
|
MISCELLANEOUS, 03102 FAST TACK ADHESIVE
| 74-98-6 75-28-5 110-54-3 108-88-3 67-64-1 |
|
MOORWOOD SOLID COLOR STAINS, 080
| 14808-60-7 13463-67-7 12001-26-2 471-34-1 14807-96-6 1309-37-1 8052-41-3 |
|
INDUSTRIAL INSULATION BOARD
| 25104-55-6 8002-74-2 24937-78-8 |
|
850 DEGREE INSULATION BOARD
| 25104-55-6 8002-74-2 24937-78-8 |
|
STANDARD DUCT WRAP
| 25104-55-6 8002-74-2 24937-78-8 |
|
UNIVERSAL BLANKET
| 25104-55-6 8002-74-2 24937-78-8 |
|
HIGH TEMPERATURE BLANKET
| 25104-55-6 8002-74-2 24937-78-8 |
|
ULTRA DUCT
| 25104-55-6 8002-74-2 24937-78-8 |
|
INSULATION FOR FLEXIBLE DUCT
| 25104-55-6 8002-74-2 24937-78-8 |
|
METAL BUILDING PANEL INSULATION
| 25104-55-6 8002-74-2 24937-78-8 |
|
TRANSPORATION INSULATION
| 25104-55-6 8002-74-2 24937-78-8 |
|
UTILITY BLANKET
| 25104-55-6 8002-74-2 24937-78-8 |
|
WALL AND PANEL INSULATION
| 25104-55-6 8002-74-2 24937-78-8 |
|
INDUSTRIAL FABRICATION BOARD
| 25104-55-6 8002-74-2 24937-78-8 |
|
RP-3 UNDERCOATING
| 64742-88-7 74-98-6 75-28-5 64742-65-0 106-97-8 8052-42-4 1317-65-3 64742-89-8 95-63-6 108-88-3 110-82-7 |
|
CAP
| 8009-03-8 64742-88-7 74-98-6 75-28-5 106-97-8 |
|
PC-7, PC-7B
| 9003-53-6 68477-30-5 9002-88-4 7778-18-9 14807-96-6 14808-60-7 8021-99-6 68410-23-1 |
|
QUICK COAT SPRAY ENAMELS, SP-501 TO SP-528
| 108-88-3 64742-89-8 75-09-2 68474-85-7 71-43-2 |
|
|