MSDS NAME:R-22
NIIN:01-367-9550
MSDS Number: BXWQC
=== Responsible Party ===
Company:DDRV STOCK MAINTENANCE DIV/DDRV-M/
Address:8000 JEFFERSON-DAVIS HIGHWAY
City:RICHMOND
State:VA
ZIP:23297
Country:US
Info Phone Num:804-279-3125
Emergency Phone Num:800-851-8061
Preparer's Name:DGSC-VBA/HMIS
CAGE:02LX8
=== Contractor Identification ===
Company:DDRV STOCK MAINTENANCE DIV/DDRV-H
Address:8000 JEFFERSON-DAVIS HIGHWAY
Box:City:RICHMOND
State:VA
ZIP:23297
Country:US
Phone:804-279-3125
CAGE:02LX8

============= Composition/Information on Ingredients =============

Name:CHLORODIFLUOROMETHANE (SARA 313) (CERCLA)
CAS:75-45-6
RTECS #:PA6390000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9495
Ozone Depleting Chemical:2

===================== Hazards Identification =====================

LD50 LC50 Mixture:TLV 1,000 PPM.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS:CNS, EYE, SKIN, LUNG.
ACUTE- HARMFUL IF INHALED. MAY CAUSE HEART IRREGULARITIES,
UNCONSCIOUSNESS OR DEATH. INTENTIONAL MISUSE IS FATAL. VAPOR
REDUCES OXYGEN & IS HEAVIER THAN AIR. EYE/SK IN CONTACT WITH LIQUID
CAN CAUSE FROSTBITE. VAPORS CAN CAUSE EYE IRRITATION. INGESTION IS
UNLIKELY. CHRONIC- UNKNOWN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:TEMPORARY NERVOUS SYSTEM DEPRESSION WITH
ANAESTHETIC EFFECTS SUCH AS DIZZINESS, HEADACHE, CONFUSION,
INCOORDINATION, LOSS OF CONSCIOUSNESS, IRREGULAR PULSE,
PALPITATIONS, INADEQUATE CIRCULATION, FROST BILTE, IRRITATION,
BLURRED VISION, TEARING
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PREEXISTING
DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURE.

======================= First Aid Measures =======================

First Aid:GET MEDICAL ATTENTION IF NEEDED. EYE/SKIN:IMMEDIATELY FLUSH
WITH PLENTY OF WATER. INHALED:REMOVE TO FRESH AIR & PROVIDE
OXYGEN/CPR IF NEEDED. ORAL:INGESTION IS NOT CONSIDERED A POTENTIAL
ROUTE OF EXPO SURE. NOTE TO PHYSICIAN:CATECHOLAMINE DRUGS SHOULD BE
USED WITH SPECIAL CAUTION ONLY IN SITUATIONS OF EMERGENCY LIFE
SUPPORT.

===================== Fire Fighting Measures =====================

Flash Point:NONE
Extinguishing Media:WATER, CO2, FOAM OR DRY CHEMICAL. WATER SPRAY MAY
BE USED TO KEEP FIRE EXPOSED CONTAINERS COOL & FLUSH SPILLS AWAY.
Fire Fighting Procedures:WEAR PROTECTIVE CLOTHING AND NIOSH-APPROVED
SELF-CONTAINED BREATHING APPARATUS. SEE 1990 EMERGENCY RESPONSE
GUIDEBOOK, DOT P 5800.5, GUIDE NO 12.
Unusual Fire/Explosion Hazard:THIS PRODUCT CAN BE DECOMPOSED BY HIGH
TEMPERATURES (OPEN FLAMES, GLOWING METALS) FORMING HYDROGEN
FLUORIDE, HYDROGEN CHLORIDE AND TRACES OF CARBONYL HALIDES.

================== Accidental Release Measures ==================

Spill Release Procedures:VENTILATE AREA, ESPECIALLY LOW PLACES WHERE
VAPORS MIGHT COLLECT. REMOVE OPEN FLAMES. USE SELF-CONTAINED
BREATHING APPARATUS FOR LARGE SPILLS OR RELEASES.
Neutralizing Agent:NOT RELEVANT

====================== Handling and Storage ======================

Handling and Storage Precautions:STORE IN A COOL, DRY, WELL VENTILATED
AREA, AWAY FROM FLAMES & INCOMPATIBLE MATERIALS. DO NOT HEAT ABOVE
125F.
Other Precautions:AVOID BREATHING VAPORS. AVOID EYE OR SKIN CONTACT.
WASH WITH SOAP AND WATER BEFORE EATING OR DRINKING. USE WITH
ADEQUATE VENTILATION. NEVER USE IN CONFINED OR CLOSED SPACES
WITHOUT PROPER PROTECTIVE E QUIPMENTS.

============= Exposure Controls/Personal Protection =============

Respiratory Protection:WEAR NIOSH-APPROVED SELF-CONTAINED BREATHING
APPARATUS OPERATED IN POSITIVE PRESSURE MODE OR SUPPLIED-AIR
RESPIRATOR WITH FULL FACEPIECE AND OPERATED IN PRESSURE-DEMAND OR
OTHER POSITIVE PRESSURE MODE IF A LARGE RELEASE OCCURS.
Ventilation:NORMAL VENTILATION IS SUFFICIENT. LOCAL EXHAUST WHEN LARGE
AMOUNTS ARE RELEASED, MECHANICAL VENTILATION IN LOW PLACES
Protective Gloves:LINED BUTYL GLOVES
Eye Protection:CHEMICAL SPLASH GOGGLES/FACE SHIELD
Other Protective Equipment:EYEBATH, SAFETY SHOWER, PROTECTIVE CLOTHING
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. DO NOT WEAR CONTAMINATED CLOTHING.
Supplemental Safety and Health
THIS MSDS WAS PREPARED BY THE PROFESSIONALS OF DGSC-VBA/HMIS WITHOUT
ANY WARRANTY. IT IS THE USER'S RESPONSIBILITY TO GATHER INFORMATION
AND USE THE MATERIAL PROPERLY TO PROTECT EMPLOYEES AND ENVIRONM
ENT. OTHER TRADE NAME: REFRIGERANT 12.

================== Physical/Chemical Properties ==================

HCC:G3
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:B.P. Text:-41F,-41C
Melt/Freeze Pt:M.P/F.P Text:-256F,-160C
Decomp Temp:Decomp Text:1170F,632C
Vapor Density:3.03 @ 77F
Spec Gravity:1.194 (LIQUID)
Viscosity:NOT RELEVANT
Evaporation Rate & Reference:>1 (CCL4 = 1)
Solubility in Water:0.30 BY WT @ 25C/77F
Appearance and Odor:CLEAR, COLORLESS LIQUEFIED GAS - SLIGHT ETHEREAL
ODOR
Percent Volatiles by Volume:100

================= Stability and Reactivity Data =================

Stability Indicator/Materials to Avoid:YES
ALKALI OR ALKALINE EARTH METALS, POWDERED ALUMINUM, ZINC, BERYLLIUM,
ETC.
Stability Condition to Avoid:FLAME, GLOWING METAL SURFACES
Hazardous Decomposition Products:MAY FORM HYDROGEN FLUORIDE, HYDROGEN
CHLORIDE AND TRACES OF CARBONYL HALIDES.

==================== Disposal Considerations ====================

Waste Disposal Methods:RECLAIM BY DISTILLATION. CONSULT LOCAL, STATE
AND FEDERAL AUTHORITIES.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
R-11 75-69-4
R-114 76-14-2
1202 75-61-6
R-12 75-71-8
1301 75-63-8
R-22 75-45-6
R-500 75-71-8
75-37-6
1211 353-59-3
R-502 75-45-6
76-15-3
R-11 75-69-4
R-11 75-69-4
134-A 811-97-2
1301 75-63-8
1301 75-63-8
1211 353-59-3
13R9 25038-59-9
25037-45-0
65181-78-4
7782-49-2
FLEETGUARD DCA 4 LIQUID COOLING CONDITIONER 7732-18-5
7778-77-0
7757-79-1
7632-00-0
10102-40-6
1312-76-1
BIO T PRESS BLANKET AND ROLLER WASH
166 2659 EKTACHEM CLINICAL CHEM CALIBRATOR KIT 2-CALIBRATOR2
166 2659 EKTACHEM CLIN CHEM CALIBRATOR KIT 2-CALIBR 2 DILUEN 7732-18-5
144-55-8
838 3101 THEROLINK 1000 SILICON THERMAL JOINT COMPOUND 118685-22-6
1314-13-2
118685-24-8
TOXAPHENE, 1X1ML, MEOH, 2000UG/ML 8001-35-2
67-56-1
BLACK DEVELOPER FOR DC-111, 111C, 113, 114, 142RE, 1001 1309-37-1
1314-13-2
1317-38-0
1317-38-0
MIL-C-83286, GRAY, 26492 111-15-9
78-93-3
141-78-6
CAT, MIL-C-83286, GRAY, 26492 108-10-1
111-15-9
108-88-3
28182-81-2
64046-64-6
1330-20-7
78-93-3
CAUSTIC SODA SOLUTION 50% REGULAR GRADE, 15216 1310-73-2
497-19-8
7647-14-5
7732-18-5
TURBO TOIL 68, 65605 64742-54-7
64742-65-0
KOOL KUT, 91620 127-18-4
71-55-6
124-38-9
DJC-201 NF AEROSOL, 5697 1717-00-6
124-38-9
PR-1154-F, PART A, (PRA 600/601)
UNISOL, 0029 71-55-6
646-06-0
78-92-2
AMBERLITE-R IRA-938 RESIN, 69436 7732-18-5
60177-39-1
MISCELLANEOUS, 03102 FAST TACK ADHESIVE 74-98-6
75-28-5
110-54-3
108-88-3
67-64-1
MOORWOOD SOLID COLOR STAINS, 080 14808-60-7
13463-67-7
12001-26-2
471-34-1
14807-96-6
1309-37-1
8052-41-3
INDUSTRIAL INSULATION BOARD 25104-55-6
8002-74-2
24937-78-8
850 DEGREE INSULATION BOARD 25104-55-6
8002-74-2
24937-78-8
STANDARD DUCT WRAP 25104-55-6
8002-74-2
24937-78-8
UNIVERSAL BLANKET 25104-55-6
8002-74-2
24937-78-8
HIGH TEMPERATURE BLANKET 25104-55-6
8002-74-2
24937-78-8
ULTRA DUCT 25104-55-6
8002-74-2
24937-78-8
INSULATION FOR FLEXIBLE DUCT 25104-55-6
8002-74-2
24937-78-8
METAL BUILDING PANEL INSULATION 25104-55-6
8002-74-2
24937-78-8
TRANSPORATION INSULATION 25104-55-6
8002-74-2
24937-78-8
UTILITY BLANKET 25104-55-6
8002-74-2
24937-78-8
WALL AND PANEL INSULATION 25104-55-6
8002-74-2
24937-78-8
INDUSTRIAL FABRICATION BOARD 25104-55-6
8002-74-2
24937-78-8
RP-3 UNDERCOATING 64742-88-7
74-98-6
75-28-5
64742-65-0
106-97-8
8052-42-4
1317-65-3
64742-89-8
95-63-6
108-88-3
110-82-7
CAP 8009-03-8
64742-88-7
74-98-6
75-28-5
106-97-8
PC-7, PC-7B 9003-53-6
68477-30-5
9002-88-4
7778-18-9
14807-96-6
14808-60-7
8021-99-6
68410-23-1
QUICK COAT SPRAY ENAMELS, SP-501 TO SP-528 108-88-3
64742-89-8
75-09-2
68474-85-7
71-43-2

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net