Search   
MSDS  : FLEETGUARD DCA 4 LIQUID COOLING CONDITIONER
CAS  : 7732-18-5
7778-77-0
7757-79-1
7632-00-0
10102-40-6
1312-76-1
NAME  : water
potassium phosphate, monobasic
potassium nitrate
sodium nitrite
molybdic acid disodium salt, dihydrate
potassium silicate
organic corrosion inhibitors
scale inhibitors and surfactants
dye, defoamer and stabilizer
===================== Product Identification =====================

MSDS NAME:FLEETGUARD DCA 4 LIQUID COOLING CONDITIONER
NIIN:01-387-1529
MSDS Number: BXWQQ
=== Responsible Party ===
Company:FLEETGUARD INC
Address:RT 8
City:COOKEVILLE
State:TN
ZIP:38501-9808
Country:US
Info Phone Num:615-526-9551
Emergency Phone Num:NONE
CAGE:4H242
=== Contractor Identification ===
Company:FLEETGUARD INC
Address:RT 8
Box:City:COOKEVILLE
State:TN
ZIP:38501-9808
Country:US
Phone:615-526-9551
CAGE:4H242

============= Composition/Information on Ingredients =============

Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 75-85%
Other REC Limits:NONE RECOMMENDED

Name:POTASSIUM PHOSPHATE, MONOBASIC
CAS:7778-77-0
Fraction by Wt: 5-15%
Other REC Limits:NONE RECOMMENDED

Name:POTASSIUM NITRATE
CAS:7757-79-1
RTECS #:TT3700000
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED

Name:SODIUM NITRITE
CAS:7632-00-0
RTECS #:RA1225000
Fraction by Wt: 1-3%
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Name:MOLYBDIC ACID DISODIUM SALT, DIHYDRATE
CAS:10102-40-6
RTECS #:QA5085000
Fraction by Wt: 0.5-2%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 (MO)
ACGIH TLV:5 MG/M3 (MO)

Name:POTASSIUM SILICATE
CAS:1312-76-1
Fraction by Wt: 0.5-2%
Other REC Limits:NONE RECOMMENDED

Name:ORGANIC CORROSION INHIBITORS
Fraction by Wt: 1-3%
Other REC Limits:NONE RECOMMENDED

Name:SCALE INHIBITORS AND SURFACTANTS
Fraction by Wt: 0.5-1.5%
Other REC Limits:NONE RECOMMENDED

Name:DYE, DEFOAMER AND STABILIZER
Fraction by Wt: 0.5-1.5%
Other REC Limits:NONE RECOMMENDED

===================== Hazards Identification =====================

Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE OVEREXPOSURE AND CHRONIC
OVEREXPOSURE SAME AS BELOW.
Explanation of Carcinogenicity:NOT CARCINOGENIC.
Effects of Overexposure:INHALE:NOT EXPECTED FOR AQUEOUS SOLUTIONS. NOT
A SENSITIZER; SKIN:IRRITATION UPON PRLONGED OR REPEATED CONTACT.
NOT A SENSITIZER; EYE:IRRITATION OR CHEMICAL BURN DUE TO MILD
ALKALINITY. INGEST:IRRITAT ION OR CHEMICAL BURN OF GI' TRACT DUE
TO MILD ALKALINITY. NITRATE & NITRITE CAN PROVE FATAL.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

======================= First Aid Measures =======================

First Aid:INHAL:REMOVE TO FRESH AIR; SKIN:WASH WITH WATER. LAUNDER
CLOTHING BEFORE REUSE. EYES:FLUSH WITH WATER & CALL A PHYSICIAN;
INGEST:GIVE CITRUS JUICE OR WATER, INDUCE VOMITING & CALL A
PHYSICIAN.

===================== Fire Fighting Measures =====================

Flash Point:NONE

================== Accidental Release Measures ==================

Spill Release Procedures:USE INDUSTRIAL ABSORBENT & BURY OR BURN. IF
LARGE AMOUNT IS SPILLED, COLLECT FOR CHEMICAL SCAVENGER SERVICE.
FLUSH AREA WITH WATER.
Neutralizing Agent:BORIC ACID OR SODIUM HYDROGEN PHOSPHATE.

====================== Handling and Storage ======================

Handling and Storage Precautions:NONE
Other Precautions:NONE

============= Exposure Controls/Personal Protection =============

Ventilation:AREA VENTILATION.
Protective Gloves:PVC OR RUBBER.
Eye Protection:CHEMICAL GOGGLES.
Other Protective Equipment:NONE.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health

================== Physical/Chemical Properties ==================

HCC:N1

================= Stability and Reactivity Data =================

Hazardous Decomposition Products:OXIDES OF NITROGEN, CARBON MONOXIDE,
CARBON DIOXIDE & SOME SULFUR OXIDES.

==================== Disposal Considerations ====================

Waste Disposal Methods:SOLIDE WASTE LANDFILL. DRUMS CAN BE RECYCLED OR
DISPOSED OF. PLASTIC PINT BOTTLES CAN BE INCINERATED.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
R-11 75-69-4
R-114 76-14-2
1202 75-61-6
R-12 75-71-8
1301 75-63-8
R-22 75-45-6
R-500 75-71-8
75-37-6
1211 353-59-3
R-502 75-45-6
76-15-3
R-11 75-69-4
R-11 75-69-4
134-A 811-97-2
1301 75-63-8
1301 75-63-8
1211 353-59-3
13R9 25038-59-9
25037-45-0
65181-78-4
7782-49-2
FLEETGUARD DCA 4 LIQUID COOLING CONDITIONER 7732-18-5
7778-77-0
7757-79-1
7632-00-0
10102-40-6
1312-76-1
BIO T PRESS BLANKET AND ROLLER WASH
166 2659 EKTACHEM CLINICAL CHEM CALIBRATOR KIT 2-CALIBRATOR2
166 2659 EKTACHEM CLIN CHEM CALIBRATOR KIT 2-CALIBR 2 DILUEN 7732-18-5
144-55-8
838 3101 THEROLINK 1000 SILICON THERMAL JOINT COMPOUND 118685-22-6
1314-13-2
118685-24-8
TOXAPHENE, 1X1ML, MEOH, 2000UG/ML 8001-35-2
67-56-1
BLACK DEVELOPER FOR DC-111, 111C, 113, 114, 142RE, 1001 1309-37-1
1314-13-2
1317-38-0
1317-38-0
MIL-C-83286, GRAY, 26492 111-15-9
78-93-3
141-78-6
CAT, MIL-C-83286, GRAY, 26492 108-10-1
111-15-9
108-88-3
28182-81-2
64046-64-6
1330-20-7
78-93-3
CAUSTIC SODA SOLUTION 50% REGULAR GRADE, 15216 1310-73-2
497-19-8
7647-14-5
7732-18-5
TURBO TOIL 68, 65605 64742-54-7
64742-65-0
KOOL KUT, 91620 127-18-4
71-55-6
124-38-9
DJC-201 NF AEROSOL, 5697 1717-00-6
124-38-9
PR-1154-F, PART A, (PRA 600/601)
UNISOL, 0029 71-55-6
646-06-0
78-92-2
AMBERLITE-R IRA-938 RESIN, 69436 7732-18-5
60177-39-1
MISCELLANEOUS, 03102 FAST TACK ADHESIVE 74-98-6
75-28-5
110-54-3
108-88-3
67-64-1
MOORWOOD SOLID COLOR STAINS, 080 14808-60-7
13463-67-7
12001-26-2
471-34-1
14807-96-6
1309-37-1
8052-41-3
INDUSTRIAL INSULATION BOARD 25104-55-6
8002-74-2
24937-78-8
850 DEGREE INSULATION BOARD 25104-55-6
8002-74-2
24937-78-8
STANDARD DUCT WRAP 25104-55-6
8002-74-2
24937-78-8
UNIVERSAL BLANKET 25104-55-6
8002-74-2
24937-78-8
HIGH TEMPERATURE BLANKET 25104-55-6
8002-74-2
24937-78-8
ULTRA DUCT 25104-55-6
8002-74-2
24937-78-8
INSULATION FOR FLEXIBLE DUCT 25104-55-6
8002-74-2
24937-78-8
METAL BUILDING PANEL INSULATION 25104-55-6
8002-74-2
24937-78-8
TRANSPORATION INSULATION 25104-55-6
8002-74-2
24937-78-8
UTILITY BLANKET 25104-55-6
8002-74-2
24937-78-8
WALL AND PANEL INSULATION 25104-55-6
8002-74-2
24937-78-8
INDUSTRIAL FABRICATION BOARD 25104-55-6
8002-74-2
24937-78-8
RP-3 UNDERCOATING 64742-88-7
74-98-6
75-28-5
64742-65-0
106-97-8
8052-42-4
1317-65-3
64742-89-8
95-63-6
108-88-3
110-82-7
CAP 8009-03-8
64742-88-7
74-98-6
75-28-5
106-97-8
PC-7, PC-7B 9003-53-6
68477-30-5
9002-88-4
7778-18-9
14807-96-6
14808-60-7
8021-99-6
68410-23-1
QUICK COAT SPRAY ENAMELS, SP-501 TO SP-528 108-88-3
64742-89-8
75-09-2
68474-85-7
71-43-2

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net