00517 DRY FILM VYDAX, MOLD RELEASE AGENTS & (SUP DAT)
CAS  
:
115-10-6 76-13-1 71-55-6 116-14-3 75-45-6
NAME  
:
volatile organic content: 23 (as a percent by weight sup dat: epinephrine in lab animals & could have similar ing 7: be contraindicated except for life-sustaining uses other prec: proc. contents under press. do not puncture, ing 9: radiators, stoves, hot water & other heat sources ing 10: keep out of reach of children. intentional misuse ing 11: be harmful/fatal. use only w/adeq vent. avoid brthg ing 12: coating may contain matls classified as nuisance ing 13: during sanding/abrading of dried film. no smoking ing 14: arc welding, open flames or hot surfaces. heat resp prot: generated from this product, underlying paint, vent: limits. refer to osha standards 1910.94, 1910.107, methyl ether vp: 760 ethane, 1,1,2-trichloro-1,2,2-trifluoro-; (sara 313) ethane, 1,1,1-trichloro-; (1,1,1-trichloroethane) (sara ethylene, tetrafloro-; (tetrafluoroethylene) vp: 16.8 methane, chlorodifluoro-; (chlorodifluoromethane) (sara
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: IRRIT OF EYES, SKIN & RESP SYS.
MAY CAUSE NERV SYS DEPRESS. EXTREME OVEREXP MAY RSLT IN UNCON &
POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORD ARE INDICATIONS OF
EXCESS EXPOS TO VAPS/SPRAY MISTS. REDNESS & ITCH/BURNING SENSATION
MAY INDICATE EYE/EXCESS SKIN EXPOS. CHRONIC: ING 4 OVEREXP MAY
CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: FLU-LIKE SYMP WHICH MAY INCL FEVER,
CHILLS, BACKACHE & NUMBNESS/TINGLING OF EXTREMITIES. INHAL OF
SMOKE/FUMES OF ING 4 MAY CAUSE POLYMER FUME FEVER, FLU-LIKE CNDTN
WHICH OCCURS SEVERAL HRS A FTER EXPOS & SUBSIDES W/IN 24 HRS. PRLNG
OVEREXP TO SOLV MAY CAUSE ADVERSE EFTS TO LIVER & URINARY SYS. (SUP
DAT)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE FROM EXPOS. RESTORE BRTHG. KEEP WARM & QUIET.
SKIN: WASH AFFECTED AREA THORO W/SOAP & WATER. REMOVE CONTAM CLTHG
& LAUNDER BEFORE REUSE. EYES: FLUSH W/LGE AMTS OF WATER FOR AT
LEAST 15 M IN. GET MED ATTN. INGEST: NEVER GIVE ANYTHING BY MOUTH
TO UNCON PERS. DO NOT INDUCE VOMIT. GIVE SEVERAL GLASSES OF WATER.
SEEK MED ATTN.
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:<0F,<-18C
Lower Limits:1.0%
Upper Limits:12.8%
Extinguishing Media:USE CARCON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD PRESS DEMAND SCBA &
FULL PROT EQUIP . WATER SPRAY MAY BE INEFFECTIVE. IF WATER IS USED,
FOG NOZZ ARE PREFERABLE. WATER MAY(SUP DAT)
Unusual Fire/Explosion Hazard:CLOSED CONTAINERS MAY EXPLODE (DUE TO THE
BUILD-UP OF PRESSURE) WHEN EXPOSED TO EXTREME HEAT. THERMAL
DECOMPOSITION PRODUCTS MAY INCLUDE HCL & PHOSGENE .
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION. VENTILATE AND
REMOVE WITH INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:CONTENTS ARE FLAMMABLE. KEEP AWAY FROM
HEAT, SPARKS AND OPEN FLAME. VAPORS WILL ACCUMULATE READILY AND MAY
IGNITE EXPLOSIVELY.
Other Precautions:DURING USE & UNTIL ALL VAPS ARE GONE, KEEP AREA VENT.
DO NOT SMOKE. EXTING ALL FLAMES, PILOT LIGHTS & HEATERS. TURN OFF
STOVES, ELEC TOOLS & APPLIANCES & ANY OTHER SOURCES OF IGNIT.
CONSULT EPA CODE. USE APPRVD BONDING & GROUNDING (ING 9)
Respiratory Protection:IF PERS EXPOS CANNOT BE CONTROLLED < APPLIC LIM
BY VENT, WEAR PROPERLY FITTED ORG VAP/PARTICULATE RESP APPRVD BY
NIOSH/MSHA FOR PROT. WHEN SANDING/ABRADING DRIED FILM, WEAR
DUST/MIST RESP APPRVD BY NI OSH/MSHA FOR DUST WHICH MAY BE (ING 16)
Ventilation:LOCAL EXHAUST PREFERABLE. GENERAL EXHAUST ACCEPTABLE IF THE
EXPOSURE IS MAINTAINED BELOW APPLICABLE EXPOSURE (ING 17)
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
ANSI DESIGN CRITERIA .
Work Hygienic Practices:WASH HANDS AFTER USING.
Supplemental Safety and Health
TRADE NAME/PART #: MOLD MAINTENANCE-2. FIRE FIGHT PROC: BE USED TO COOL
CLSD CONTRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN
EXPOSED TO EXTREME HEAT. EFTS OF OVEREXP: REPORTS HAVE ASSOC RPTD
& PRLNG OVEREXP TO SOLV W/PERM BRAIN &NERV SYS DMG. CHLOROCARBON
MATLS HAVE PRODUCED SENSIT OF MYOCARDIUM TO (ING 7)
Waste Disposal Methods:WASTE FROM THIS PROD MAY BE HAZ AS DEFINED UNDER
RCRA 40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE
APPLIC EPA HAZ WASTE #. DO NOT INCIN. DEPRESSURIZE CONTR. DISPOSE
OF I/A/W LOCAL, S TATE & FEDERAL REGULATIONS REGARDING POLLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.