===================== Product Identification =====================
MSDS NAME:900 0385 COLOR DEVELOPER AND REPLENISHER MX1548-1, PART B
NIIN:00K005713
Kit Part:Y
MSDS Number: CCMNJ
=== Responsible Party ===
Company:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-477-3194 MSDS :800- 242-2424
Emergency Phone Num:716-722-5151
CAGE:19139
=== Contractor Identification ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
Company:EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
Address:800 LEE RD
Box:City:ROCHESTER
State:NY
ZIP:14650-3129
Country:US
Phone:800-828-6203
CAGE:5K871
============= Composition/Information on Ingredients =============
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 95-99%
Other REC Limits:NONE RECOMMENDED
Ingred
Name:4-(N-ETHYL-N-2-METHANESULFONYLAMINOETHYL)-2-METHYLPHENYLENEDIA
MINE
CAS:25646-71-3
RTECS #:PB0431000
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED
Name:1,2-ETHYLENEDITHIODIETHANOL
CAS:5244-34-8
Fraction by Wt: < 1%
Other REC Limits:NONE RECOMMENDED
Name:SODIUM BISULFITE (SASA III) (CERCLA)
CAS:7631-90-5
RTECS #:VZ2000000
Fraction by Wt: < 1%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3
ACGIH TLV:5 MG/M3; 9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RAT): 400 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPECTED TO BE A LOW INHALATION HAZARD
FOR RECOMMENDED HANDLING. LIBERATES SULFUR DIOXIDE GAS WHICH CAN
CAUSE IRRITATION TO THE RESPIRATORY TRACT. EYE CONTACT MAY CAUSE
IRRITATION. SKIN CONTACT MAY CA USE ALLERGIC SKIN REACTION.
INGESTION MMAY CAUSE IRRITATION OF GI TRACT.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:RESPIRATORY TRACT IRRITATION, EYE IRRITATION,
ALLERGIC SKIN REACTION, GI TRACT IRRITATION, SOME ASTHMATICS OR
SULFITE-SENSITIVE INDIVIDUALS MAY EXPERIENCE WHEEZING, CHEST
TIGHTNESS, STOMACH UPSET, HIV ES, FAINTNESS, WEAKNESS AND DIARRHEA.
Medical Cond Aggravated by Exposure:SOME ASTHMATICS OR HYPERSENSITIVE
INDIVIDUALS MAY EXPERIENCE DIFFICULT BREATHING.
======================= First Aid Measures =======================
First Aid:INHALATION: IF SYMPTOMATIC, MOVE TO FRESH AIR. GET MEDICAL
ATTENTION IF SYMPTOMS PERSIST. EYES: WASH OUT IMEEDIATELY WITH
WATER. GET MEDICAL ATTENTION IF SYMPTOMS OCCUR. SKIN: WASH WITH
SOAP AND WATER . GET MEDICAL ATTENTION IF SYMPTOMS OCCUR.
INGESTION: DRINK 1-2 GLASSES OF WATER. SEEK MEDICAL ATTENTION.
NEVER GIVE ANYTHING BY MOUTH TO AN UNCONSCIOUS PERSON.
===================== Fire Fighting Measures =====================
Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB SPILL WITH VERMICULITE OR OTHER INERT
MATERIAL, THEN PLACE IN A CONTAINER FOR CHMEICAL WASTE. CLEAN
SURFACE THOROUGHLY TO REMOVE RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT WITH EYES, SKIN AND
CLOTHING. USE WITH ADEQUATE VENTILATION. WASH THOROUGHLY AFTER
HANDLING. KEEP CONTAINER CLOSED.
Other Precautions:THE ROUTINE USE OF A NONALKALINE (ACID) TYPE OF HAND
CLEANER AND REGULAR CLEANING OF WORKING SURFACES WILL HELP MINIMIZE
THE POSSIBILITY OF A SKIN REACTION.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF ENGINEERING CONTROLS DO NOT MAINTAIN AIRBORNE
CONCENTRATIONS BELOW RECOMMENDED EXPOSURE LIMITS, AN APPROVED
RESPIRATOR MUST BE WORN. RESPIRATOR TYPE: ACID GAS. IF RESPIRATORS
ARE USED, A PROGRAM SH OULD BE INSTITUTED.
Ventilation:GOOD GENERAL VENTILATION, TYPICALLY 10 AIR CHANGES PER
HOUR, SHOULD BE USED. RATES SHOULD MATCH CONDITIONS.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES W/SIDE SHIELDS OR GOGGLES
Other Protective Equipment:CHEMICAL RESISTANT CLOTHING AS NECESSARY TO
PREVENT SKIN CONTACT. AN EMERGENCY EYEWASH AND SHOWER SHOULD BE
AVAILABLE.
Work Hygienic Practices:WASH HANDS THOROUGHLY WITH SOAP AND WATER
BEFORE EATING, DRINKING, SMOKING OR USING TOILET FACILITIES.
Supplemental Safety and Health
REMOVE AND WASH CONTAMINATED CLOTHING BEFORE REUSE. KEY1:C2.
================== Physical/Chemical Properties ==================
HCC:C2
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:NOT GIVEN
Vapor Pres:18
Vapor Density:0.6
Spec Gravity:1.17
pH:1.4
Evaporation Rate & Reference:NOT GIVEN
Solubility in Water:COMPLETE
Appearance and Odor:COLORLESS LIQUID, SULFUR DIOXIDE ODOR
Percent Volatiles by Volume:95-99%
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
BASES.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:NONE SPECIFIED BY MANUFACTURER.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISCHARGE, TREATMENT OR DISPOSAL MAY BE SUBJECT
TO NATIONAL, STATE OR LOCAL LAWS. DISPOSE OF IN ACCORDANCE WITH ALL
APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|