===================== Product Identification =====================
MSDS NAME:00522 522 OIL 19
NIIN:00N073872
MSDS Number: CCPWK
=== Responsible Party ===
Company:TEXACO LUBRICANTS CO
Box:52332
City:HOUSTON
State:TX
ZIP:77052
Country:US
Info Phone Num:914-838-7204;914-838-7509
Emergency Phone Num:914-831-3400;800-424-9300(CHEMTREC)
CAGE:OTTJ3
=== Contractor Identification ===
Company:TEXACO LUBRICANTS
Address:4164 E INNSLAKE DR
Box:4427
City:GLEN ALLEN
State:VA
ZIP:23060
Country:US
Phone:804-527-4311
CAGE:OTTJ3
Company:TEXACO PIPELINE INC (SUB OF TEXACO INC)
Address:9700 RICHMOND AVE
Box:42286
City:HOUSTON
State:TX
ZIP:77242-2286
Country:US
Phone:713-953-4260
CAGE:3B431
============= Composition/Information on Ingredients =============
Name:MINERAL OIL, PETROLEUM DISTILLATE, SOLVENT DEWAXED
(SEVERE), HEAVY PARAFFINIC
CAS:64742-65-0
RTECS #:PY8038501
Fraction by Wt: 100%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:VOLATILE ORGANIC COMPOUND:100%
RTECS #:9999999VO
OSHA PEL:N/K
ACGIH TLV:N/K
Name:SUPDAT:LAVAGE AFTER ENDOTRACHEAL INTUBATION. REMOVE &
DRY-CLEAN/LAUNDER CLTHG SOAKED/SOILED W/THIS MATL BEFORE (ING 4)
RTECS #:9999999ZZ
Name:ING 3:REUSE. DRY CLEANING OF CONTAMD CLTHG MAY BE MORE
EFTIVE THAN NORM LAUNDERING. INFORM INDIVIDUALS (ING 5)
RTECS #:9999999ZZ
Name:ING 4:RESPONSIBLE FOR CLEANING OF POTNTL HAZARDS ASSOC
W/HANDLING CONTAMD CLOTHING.
RTECS #:9999999ZZ
Name:WASTE DISP METH:WHETHER PROD MEETS RCRA CRITERIA FOR HAZ
WASTE. THIS IS BECAUSE-PROD USES, TRANSFORMATIONS, (ING 7)
RTECS #:9999999ZZ
Name:ING 6:MIXTURES, PROCESSES, ETC, MAY RENDOR THE RESULTING
MATERIALS HAZARDOUS.
RTECS #:9999999ZZ
Name:RESP PROT:CONFINED SPACES. SEE APPLICABLE PEL
CONCENTRATIONS.
RTECS #:9999999ZZ
Name:HYGIENE PRACT:DRY-CLEANED AT LEAST ONCE A WEEK.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:MAY CAUSE MINIMAL IRRIT,
EXPERIENCED AS TEMPORARY DISCOMFORT. SKIN:BRIEF CONT IS NOT IRRIT.
PRLNGD CONT, AS W/CLTHG COATED W/MATL, MAY CAUSE DEFAT OF
SKIN/IRRIT, SEEN AS LOC REDNESS W/POSS MILD DISCOMFORT.
INHAL:VAPS/MIST, IN EXCESS OF PEL CONCS/IN UNUSUALLY HIGH CONCS
GENERATED FROM (EFTS OF OVEREX)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SPRAYING, HEATING MATL/AS FROM EXPOS
IN POORLY VENTILATED AREAS/CONFINED SPACES, MAY CAUSE IRRIT OF NOSE
& THROAT, HDCH, NAUS, & DROW. INGEST:IF MORE THAN SEVERAL MOUTHFULS
ARE SWALLOWED, ABD OM DISCOMFORT, NAUS, & DIARR MAY OCCUR.ASPIR MAY
OCCUR DURING SWALLOWING/VOMITING RESULTING IN LUNG DAMAGE.
Medical Cond Aggravated by Exposure:BECAUSE OF ITS DEFATTING
PROPERTIES, PROLONGED & REPEATED SKIN CONTACT MAY AGGRAVATE AN
EXISTING DERMATITIS (SKIN CONDITION).
======================= First Aid Measures =======================
Eyes:FLUSH W/PLENTY OF WATER FOR @ LST 15 MINS. GET MED ATTN
IF IRRIT PERSISTS. SKIN:WASH W/PLENTY OF SOAP & WATER FOR SEVERAL
MINS. GET MED ATTN IF IRRIT DEVELOPS/PERSISTS. INGEST:GET IMMED MED
ATTN. ONLY INDUCE VOMIT AS DIRECTED BY MD. NEVER GIVE ANYTHING BY
MOUTH TO UNCON/CONVULSING PERSON. INHAL:IF IRRIT, HDCH, NAUS/DROW
OCCURS, REMOVE TO FRESH AIR. GET MED ATTN IF BRTHG BECOMES (SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:350F,177C
Extinguishing Media:ACCORDING TO NFPA GUIDE, USE WATER SPRAY, DRY
CHEMICAL, FOAM, OR CARBON DIOXIDE.
Fire Fighting Procedures:NIOSH APPRVD SCBA & FULL PROT EQUIP . WATER OR
FOAM MAY CAUSE FROTHING. USE WATER TO COOL FIRE-EXPOS CNTNRS. IF
LEAK/SPILL HAS NOT IGNITED, USE (SUDPAT)
Unusual Fire/Explosion Hazard:NONE.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA. AVOID BRTHG VAP. USE NIOSH
APPRVD SCBA/SUPPLIED AIR FOR LG SPILLS/CONFINED AREAS. CNTN SPILL
IF POSS. WIPE UP/ABSORB ON SUITABLE MATL & SHOVEL UP. PVNT ENTRY
INTO SEWERS & WATERWAYS. A VOID CONT W/SKIN, EYES OR CLTHG.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:MINIMUM FEASIBLE HNDLG TEMPERATURES
SHOULD BE MAINTAINED. PERIODS OF EXPOSURE TO HIGH TEMPERATURES
SHOULD BE MINIMIZED.
Other Precautions:WATER CONTAMINATION SHOULD BE AVOIDED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:AIRBORNE CONCS SHOULD BE KEPT TO LOWEST LEVS
POSS. IF VAP, MIST/DUST IS GENERATED, USE RESP APPRVD BY NIOSH AS
APPROP. NIOSH APPRVD SUPPLIED AIR RESP PROT SHOULD BE USED FOR
CLEANING LG SPILLS/UPON EN TRY INTO TANKS, VESSELS/OTHER (ING 8)
Ventilation:ADEQUATE TO MEET COMPONENT OCCUPATIONAL EXPOSURE LIMITS
(SEE INGREDIENT SECTION).
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:WORKERS SHOULD WASH EXPOS SKIN SEVERAL TIMES
DAILY W/SOAP & WATER. SOILED WORK CLTHG SHOULD BE LAUNDERED OR (ING
9)
Supplemental Safety and Health
FIRE FIGHT PROC:WATER SPRAY TO DISPERSE VAPS & TO PROVIDE PROT FOR
PERSONS ATTEMPTING TO STOP LEAK. FIRST AID PROC:DFCLT/SYMPS
PERSIST. NOTE TO PHYS:ASPIR OF PROD DURING INDUCED EMESIS CAN RSLT
IN LUN G INJURY. IF EVAC OF STOM CONTENTS IS CONSIDERED NEC, USE
METH LST LIKELY TO CAUSE ASPIR, SUCH AS GASTRIC (ING 3)
================== Physical/Chemical Properties ==================
Spec Gravity:0.86 (H*2O=1)
Evaporation Rate & Reference:NOT KNOWN
Solubility in Water:NOT KNOWN
Appearance and Odor:PALE LIQUID.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:TOXIC LEVELS OF CARBON MONOXIDE,
CARBON DIOXIDE. IRRITATING ALDEHYDES & KETONES.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISP MUST BE I/A/W FED, ST & LOC REGS . THIS
PROD HAS BEEN EVAL FOR RCRA CHARACT & DOES NOT MEET CRITERIA OF HAZ
WASTE IF DISCARDED IN ITS PURCHASED FORM. UNDER RCRA, IT IS
RESPONSIBILITY OF USE R OF PROD TO DETERM @ TIME OF DISPOSAL,(ING
6)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|