Search   
MSDS  
:
 023477-000 NICKEL CADMIUM AIRCRAFT BATTERY
CAS  
:
 1313-99-1
1310-58-3
1306-19-0
7440-50-8
NAME  
:
 nickel oxide
electrolyte solution (30% potassium hydroxide) (cercla)
cadmium oxide (sara 302/313) (cercla)
copper (sara 313) (cercla)
=====================  Product Identification  =====================

MSDS NAME:023477-000 NICKEL CADMIUM AIRCRAFT BATTERY
NIIN:01-186-3711
MSDS Number: CDGPZ
=== Responsible Party ===
Company:SAFT AMERICA INC, POWER SOURCES DIV
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31603
Country:US
Info Phone Num:912-247-2331
Emergency Phone Num:912-247-2331
CAGE:09052
=== Contractor Identification ===
Company:SAFT AMERICA INC.
Address:711 INDUSTRIAL BLVD
Box:1886
City:VALDOSTA
State:GA
ZIP:31602
Country:US
Phone:912-247-2331
CAGE:09052

=============  Composition/Information on Ingredients  =============

Name:NICKEL OXIDE
CAS:1313-99-1
RTECS #:QR8400000
Fraction by Wt: 18%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1 MG/M3 AS NI
ACGIH TLV:1 MG/M3 AS NI

Name:ELECTROLYTE SOLUTION (30% POTASSIUM HYDROXIDE) (CERCLA)
CAS:1310-58-3
RTECS #:TT2100000
Fraction by Wt: 19%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C 2 MG/M3
ACGIH TLV:C 2 MG/M3; 9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Name:CADMIUM OXIDE (SARA 302/313) (CERCLA)
CAS:1306-19-0
RTECS #:EV1925000
Fraction by Wt: 13%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.2 MG (CD)/M3 DUST
ACGIH TLV:0.01 MG(CD)/M3; 9596

Name:COPPER (SARA 313) (CERCLA)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: 9%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:0.1MG/M3 FUME/1 DUST
ACGIH TLV:0.2 MG/M3 FUME; 9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:YES    IARC:YES	  OSHA:YES
Health Hazards Acute and Chronic:EYE/SKIN CONTACT WITH ELECTROLYTE MAY
    CAUSE SEVERE IRRITATION/BURNS; BLINDNESS. CONTACT WITH NICKEL MAY
    CAUSE ECZEMA. INGESTION OF ELECTROLYTE MAY CAUSE DAMAGE TO THROAT &
    STOMACH TISSUE. INHALATION O F VAPORS/MISTS/FUMES MAY CAUSE
    IRRITATION OF UPPER RESPIRATORY TRACT. CHRONIC: SEE SUPPLEMENTAL
    DATA.
Explanation of Carcinogenicity:CONTAINS CADMIUM [7440-43-9] WHICH IS
    LISTED BY NTP & IARC & REGULATED BY OSHA AS A CARCINOGEN; ALSO
    NICKEL (NTP/IARC).
Effects of Overexposure:INHALED: COUGHING, SNEEZING, WHEEZING,
    SHORTNESS OF BREATH, CHILLS, WEAKNESS, COUGHING, CHEST PAINS. SKIN:
    REDNESS, ITCHING, DISCOMFORT. INGESTED: NAUSEA, VOMITING, DIARRHEA,
    ABDOMINAL CRAMPS.
Medical Cond Aggravated by Exposure:RESPIRATORY SYSTEM DISORDERS,
    PROSTATE DISORDERS, LIVER AND KIDNEY DISORDERS.

=======================  First Aid Measures  =======================

First Aid:EYES-FLUSH WITH LOTS OF WATER FOR 15 MINUTES. GET IMMEDIATE
    MEDICAL ATTENTION. SKIN-REMOVE CONTAMINATED CLOTHES. FLUSH WITH
    WATER FOR AT LEAST 15 MINUTES. INGESTED-DO NOT INDUCE VOMITING!
    DILUTE BY GI VING WATER OR MILK. GET IMMEDIATE MEDICAL ATTENTION.
    NOTHING BY MOUTH IF UNCONSCIOUS. INHALED-REMOVE TO FRESH AIR. GIVE
    OXYGEN OR ARTIFICIAL RESPIRATION IF NEEDED. GET IMMEDIATE MEDICAL
    ATTENTION.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:CARBON DIOXIDE, SAND.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    FULL PROTECTIVE CLOTHING IF INVOLVED IN A FIRE. DISCONNECT ALL
    CABLES TO & FROM BATTERY.
Unusual Fire/Explosion Hazard:ELECTROLYTE SOLUTION IS CORROSIVE TO ALL
    HUMAN TISSUES. IT WILL REACT WITH MANY ORGANIC CHEMICALS,
    ESPECIALLY NITROCARBONS & CHLOROCARBONS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:ELECTROLYTE SOLUTION-FLUSH WITH WATER.
    NEUTRALIZE WITH DILUTE CITRIC ACID.
Neutralizing Agent:DILUTE CITRIC ACID.

======================	Handling and Storage  ======================

Handling and Storage Precautions:WEAR PROPER PROTECTIVE CLOTHING. STORE
    IN A COOL, DRY AREA. PERFORM LEVEL CHARGING PROCEDURES IN A WELL
    VENTILATED AREA.
Other Precautions:BATTERY OPERATING AREAS NEED TO BE WELL VENTILATED TO
    REMOVE NORMAL GASES GENERATED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR DURING LEVEL
    CHARGING TO MAINTAIN EXPOSURE LEVELS BELOW THE TWA.
Ventilation:DLA-HMIS: USE ADEQUATE MECHANICAL VENTILATION OR LOCAL
    EXHAUST TO MAINTAIN EXPOSURE BELOW PEL/TLV.
Protective Gloves:SYNTHETIC RUBBER.
Eye Protection:CHEMICAL SPLASH GOGGLES+FACESHIELD.
Other Protective Equipment:RUBBER BOOTS,RUBBER APRON OR RAINWEAR IF
    EXPOSURE TO ELECTROLYTE LIKELY.HMIS:EYE WASH STATION & SAFETY
    SHOWER AVAILABLE.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
    DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
MSDS PROVIDED BY CAGE 09052 FOR CONTRACT NUMBER SPO430-95-D-0169.
    CHRONIC HEALTH CONT'D: CHRONIC OVEREXPOSURE TO CADMIUM COMPOUNDS
    MAY RESULT IN PULMONARY EDEMA, BREATHING DIFFICULTY, PROSTATION,
    KIDN EY DAMAGE. NIOSH RECOMMENDS THAT NICKEL& CADMIUM BE TREATED AS
    OCCUPATIONAL CARCINOGENS.

==================  Physical/Chemical Properties  ==================

HCC:B1
Spec Gravity:1.25ELECTROLYTE
Evaporation Rate & Reference:UNDETERMINED
Solubility in Water:COMPLETE-ELECTROLYTE
Appearance and Odor:BATTERY ASSMBLY. 19 BATTERIES. 11.25' X 11.81' X
    10.31'.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ELECTROLYTE-ORGANIC CHEMICALS, ZINC, ALUMINUM, OTHER ACTIVE
    MATERIALS-RELEASES HYDROGEN GAS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CADMIUM, POTASSIUM HYDROXIDE, NICKEL
    OXIDE, CADMIUM OXIDE FUMES MAY BE EVOLVED AT TEMPERATURES ABOVE
    MELTING POINT.

====================  Disposal Considerations  ====================

Waste Disposal Methods:THE STORAGE BATTERY IS A HAZARDOUS WASTE UNDER
    RCRA. DO NOT ALLOW MATERIAL TO ENTER SEWERS, STREAMS OR STORM
    CONDUITS. RECOVER MATERIAL W/VACUUM TRUCK & DISPOSE OF PROPERLY. RQ
    (ELECTROLYTE)=1000 LBS.  BATTERY IS TCLP TOXIC
    (+ELECTROLYTE=CORROSIVE).

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 1 DILUENT 7732-18-5
144-55-8
64-17-5
853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 2 DILUENT 12125-02-9
7732-18-5
144-55-8
64-17-5
853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 3 DILUENT 7732-18-5
144-55-8
64-17-5
12125-02-9
SLICK 50 AUTOMATIC TRANSMISSION FORMULA, CODE#:41612008C 64741-88-4
64741-89-5
68649-42-3
MAN TRANS/MANUAL TRANSMISSION & GEAR FORMULA(100%COMPATIBLE) 64742-54-7
ONE GREASE, CODE#:40906001/40906145
SMARTWASHER FL3 FLUID ACTIVATION FILTER
SW1 SMARTWASHER ACTIVATING DEGREASING SOLUTION
835 6461 CITRZINIC ACID 99-11-6
P103337 (CONTAINS AROCHLOR 1016) 1336-36-3
JAN 249C HALF WAVE RECTIFIER 7439-97-6
METHYL PURPLE INDICATOR 845-10-3
DARCO ACTIVATED BASED CARBON 7440-44-0
SODIUM JHYDROXIDE,50% CODE:SOH50 (CATALOG#:S1310) 1310-73-2
7732-18-5
857B ELECTRON TUBE MERCURY VAPOR DIODE 7439-97-6
DENATURED ALCOHOL, SDA-31 64-17-5
67-56-1
67-63-0
HYDROGEN (1-2%) IN AIR 1333-74-0
PLY 3 PROTECTIVE CREAM 7732-18-5
8006-54-0
8009-03-8
57-11-4
8042-47-5
557-05-1
102-71-6
99-76-3
CUTTING FLUID, VV-C-846 64742-52-5
146 3272 POTASSIUM BROMIDE (ANHYDROUS) 7758-02-3
146 3280 POTASSIUM BROMIDE (ANHYDROUS) 7758-02-3
NL615 HALF WAVE RECTIFIER (MERCURY) 7439-97-6
CEE BEE J-84 L CONCENTRATE 1310-73-2
155 9566 KODALITH SUPER RT DEVELOPER,PART A 870-72-4
123-31-9
10043-35-3
7757-83-7
10124-56-8
155 9566 KODALITH SUPER RT DEVELOPER,PART B 497-19-8
7758-02-3
10124-56-8
155 9566 KODALITH SUPER RT DEVELOPER,WORKING SOLUTION 7732-18-5
497-19-8
870-72-4
123-31-9
10043-35-3
2000, 2300 COPIER TONER 7439-89-6
68650-50-0
1333-86-4
8005-02-5
TELLUS OIL 100 64742-54-7
150 1931 ANTI-FOG,6 6112-39-6
REWARD AQUATIC & NON-CROP HERBICIDE 85-00-7
106-93-4
162 8007 RECORDAK ELECTROSTATIC 12 N TONER 64475-85-0
P/N 3300006 HALON 1301 75-63-8
C31HE-2 WET;LEAD/ACID BATTERY 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
7440-31-5
VISILOX V-740 1314-13-2
63148-82-3
153 4890 AQUA-IMAGE NEGATIVE FINISHER, READY-TO-USE 7732-18-5
9004-53-9
7558-80-7
9003-39-8
DALIC SOLUTION TIN, CODE 2090 7440-31-5
107-15-3
7732-18-5
P/N 30101006 SIFCO DALIC SOLUTION CLEANER & DEOXIDIZER 1310-73-2
7732-18-5
LEAD-ACID BATTERY 7439-92-1
7440-36-0
7440-38-2
7440-70-2
7440-31-5
7664-93-9
9003-07-4
60676-86-0
PN:75-26222-01 ANACOMP-AUTOPOS 2000 FIRST DEVELOPER 123-31-9
1310-73-2
109-83-1
PN:75-26222-02 ANACOMP-AUTOPOS 2000 SECOND DEVELOPER 123-31-9
1310-73-2
109-83-1
PN:75-272521 ANACOMP-AUTOPOS 2000 FIXER 7783-18-8
10192-30-0
PN:75-28202-00 ANACOMP-AUTOPOS 2000 ARCHIVAL WASH
PN:75-29202-00 ANACOMP-AUTOPOS 2000 FINAL WASH
SCOTCHGARD BRAND CLEANER FOR FABRIC & UPHOLSTERY,1014 7732-18-5
75-28-5
151-21-3
1643-20-5
111-76-2
25882-44-4
67-63-0
DUPONOL WA PASTE SURFACTANT 151-21-3
1191-50-0
1120-01-0
7647-14-5
7732-18-5
STIMUKIL FLY BAIT 16752-77-5
023477-000 NICKEL CADMIUM AIRCRAFT BATTERY 1313-99-1
1310-58-3
1306-19-0
7440-50-8
LITHIUM OXYHALIDE PRIMARY BATTERY (BCXII) 7439-93-2
7791-25-5
7782-50-5
P/N 34000004-2 HALON 1301 75-63-8
TADIRAN LITHIUM INORGANIC 3.6V BATTERY,SIZE AA. 7719-09-7
7439-93-2
7446-70-0
7447-41-8

Free MSDS Search ( Providing 250,000+ Material Properties )