Search   
MSDS  
:
 JAN 249C HALF WAVE RECTIFIER
CAS  
:
 7439-97-6
NAME  
:
 mercury (sara 313) (cercla)
=====================  Product Identification  =====================

MSDS NAME:JAN 249C HALF WAVE RECTIFIER
NIIN:00-108-0265
MSDS Number: CDGNG
=== Responsible Party ===
Company:CETRON ELECTRONICS DIV RICHARDSON ELECTRONICS LTD
Address:40W267 KESLINGER RD
City:LAFOX (FORMALLY IN GEVEVA)
State:IL
ZIP:60147
Country:US
Info Phone Num:312-232-6400 /FAX 708-208-2559
Emergency Phone Num:312-232-6400 /800-523-6970
Preparer's Name:PJ IGOE
CAGE:72241
=== Contractor Identification ===
Company:CETRON ELECTRONICS DIV RICHARDSON ELECTRONICS LTD
Address:40W267 KESLINGER RD
Box:City:LAFOX
State:IL
ZIP:60147
Country:US
Phone:708-208-2300
CAGE:72241
Company:NATIONAL ELECTRONICS DIV OF RICHARDSON ELECTRONICS
Address:40W267 KESLINGER RD
Box:City:LAFOX
State:IL
ZIP:60147
Country:US
CAGE:83781

=============  Composition/Information on Ingredients  =============

Name:MERCURY (SARA 313) (CERCLA)
CAS:7439-97-6
RTECS #:OV4550000
Other REC Limits:NONE RECOMMENDED
OSHA PEL:C, 0.1 MG/M3; Z-2
ACGIH TLV:S,0.025 MG/M3; A4;96
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LC (INHALATION-RABBIT)= 29 MG/CUM(30HRS)
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EXPOSURE TO MERCURY FROM RUPTURED
    TUBES MAY CAUSE CNS EFFECTS/DAMAGE, EROSION OF RESPIRATORY/GI
    TRACTS, RESPIRATORY DAMAGE/IRRITATION. CHRONIC: PROLONGED OR
    REPEATED EXPOSURE TO MERCURY MAY CAUSE CNS	DAMAGE, KIDNEY DAMAGE,
    EYE DAMAGE, AND DERMATITIS.
Explanation of Carcinogenicity:MERCURY IS NOT LISTED AS A CARCINOGEN OR
    SUSPECTED CARCINOGEN BY NTP, IARC, OR OSHA.
Effects of Overexposure:NAUSEA, VOMITING, BLOODY DIARRHEA, SHOCK,
    HEADACHE, GINGIVITIS, SALIVATION, TREMORS, EMOTIONAL PROBLEMS, LOSS
    OF CONCENTRATION, DEPRESSION, DROWSINESS, PNEUMONITIS, CHEST PAIN,
    DYSPNEA, INSOMNIA, LOSS  OF MEMORY, KIDNEY PROBLEMS, EYE LESIONS,
    VISION DISTURBANCES.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALED: REMOVE TO FRESH AIR. GET MEDICAL ATTENTION. EYES:
    FLUSH WITH LOTS OF WATER FOR 15 MINUTES, HOLD LIDS OPEN. GET
    MEDICAL ATTENTION. SKIN: WASH WITH SOAP AND WATER. INGESTED: GET
    IMMEDIATE MEDIC AL ATTENTION. NOTE TO DOCTOR-IF INDICATED BY AMOUNT
    INGESTED, USE SALINE CATHARTICS & CHARCOAL. CHELATION THERAPY WITH
    D- PENICILLAMINE MAY ALSO BE INDICATED.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:MEDIA APPROPRIATE FOR SURROUNDING FIRE.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
    FULL PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:WHEN EXPOSED (AND/OR TUBE RUPTURES)
    MERCURY CAN VAPORIZE FORMING EXTREMELY TOXIC FUMES.

==================  Accidental Release Measures  ==================

Spill Release Procedures:VACUUM BROKEN PIECES OF TUBE WITH VACUUM
    EQUIPPED WITH HEPA FILTRATION OF EXHAUST OR SPECIAL BUILT VACUUM
    FOR MERCURY.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE. PROTECT
    FROM PHYSICAL DAMAGE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NONE NORMALLY REQUIRED. IF EMERGENCY OCCURS AND
    TUBES RUPTURE; USE NIOSH/MSHA APPROVED RESPIRATOR OR SCBA. USE IN
    ACCORDANCE WITH 29 CFR 1910.134.
Ventilation:NONE NORMALLY REQUIRED.
Protective Gloves:SPILL-RUBBER.
Eye Protection:SAFETY GLASSES
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH HANDS AFTER USE AND BEFORE EATING,
    DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health
MSDS SUPPLIED BY MANUFACTURER WAS FOR PURE MERCURY, NOT AN ELECTRON
    TUBE CONTANING SOME FORM OF MERCURY. ITEM OF SUPPLY MEETS
    DEFINITION BY OSHA FOR AN ARTICLE AND DOES NOT REQUIRE AN MSDS.

==================  Physical/Chemical Properties  ==================

HCC:N1
Solubility in Water:INSOLUBLE
Appearance and Odor:METAL SHROUDED ELECTRON TUBE

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
ACETYLENE, AMMONIA, BORON PHOSPHOIODIDE, CHLORINE, CHLORINE DIOXIDE,
    METHYL AZIDE, SODIUM, NITRIC, OLEUM, SULFURIC ACID
Stability Condition to Avoid:CONTACT WITH INCOMPATIBLE MATERIALS. HIGH
    TEMPERATURES.
Hazardous Decomposition Products:MERCURY METAL FUMES IF TUBE INTEGRITY
    LOST, ESPECIALLY UNDER CONDITIONS OF HIGH TEMPERATURES OR FIRE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH LOCAL, STATE AND
    FEDERAL REGULATIONS FOR MERCURY. EPA WASTE NUMBER U121 MAY APPLY.
    CERCLA RQ= 1 POUND.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 1 DILUENT 7732-18-5
144-55-8
64-17-5
853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 2 DILUENT 12125-02-9
7732-18-5
144-55-8
64-17-5
853 3622 KODAK EKTACHEM CALIBRATOR KIT1-CALIBRATOR 3 DILUENT 7732-18-5
144-55-8
64-17-5
12125-02-9
SLICK 50 AUTOMATIC TRANSMISSION FORMULA, CODE#:41612008C 64741-88-4
64741-89-5
68649-42-3
MAN TRANS/MANUAL TRANSMISSION & GEAR FORMULA(100%COMPATIBLE) 64742-54-7
ONE GREASE, CODE#:40906001/40906145
SMARTWASHER FL3 FLUID ACTIVATION FILTER
SW1 SMARTWASHER ACTIVATING DEGREASING SOLUTION
835 6461 CITRZINIC ACID 99-11-6
P103337 (CONTAINS AROCHLOR 1016) 1336-36-3
JAN 249C HALF WAVE RECTIFIER 7439-97-6
METHYL PURPLE INDICATOR 845-10-3
DARCO ACTIVATED BASED CARBON 7440-44-0
SODIUM JHYDROXIDE,50% CODE:SOH50 (CATALOG#:S1310) 1310-73-2
7732-18-5
857B ELECTRON TUBE MERCURY VAPOR DIODE 7439-97-6
DENATURED ALCOHOL, SDA-31 64-17-5
67-56-1
67-63-0
HYDROGEN (1-2%) IN AIR 1333-74-0
PLY 3 PROTECTIVE CREAM 7732-18-5
8006-54-0
8009-03-8
57-11-4
8042-47-5
557-05-1
102-71-6
99-76-3
CUTTING FLUID, VV-C-846 64742-52-5
146 3272 POTASSIUM BROMIDE (ANHYDROUS) 7758-02-3
146 3280 POTASSIUM BROMIDE (ANHYDROUS) 7758-02-3
NL615 HALF WAVE RECTIFIER (MERCURY) 7439-97-6
CEE BEE J-84 L CONCENTRATE 1310-73-2
155 9566 KODALITH SUPER RT DEVELOPER,PART A 870-72-4
123-31-9
10043-35-3
7757-83-7
10124-56-8
155 9566 KODALITH SUPER RT DEVELOPER,PART B 497-19-8
7758-02-3
10124-56-8
155 9566 KODALITH SUPER RT DEVELOPER,WORKING SOLUTION 7732-18-5
497-19-8
870-72-4
123-31-9
10043-35-3
2000, 2300 COPIER TONER 7439-89-6
68650-50-0
1333-86-4
8005-02-5
TELLUS OIL 100 64742-54-7
150 1931 ANTI-FOG,6 6112-39-6
REWARD AQUATIC & NON-CROP HERBICIDE 85-00-7
106-93-4
162 8007 RECORDAK ELECTROSTATIC 12 N TONER 64475-85-0
P/N 3300006 HALON 1301 75-63-8
C31HE-2 WET;LEAD/ACID BATTERY 7439-92-1
7440-36-0
7440-38-2
7664-93-9
7440-70-2
7440-31-5
VISILOX V-740 1314-13-2
63148-82-3
153 4890 AQUA-IMAGE NEGATIVE FINISHER, READY-TO-USE 7732-18-5
9004-53-9
7558-80-7
9003-39-8
DALIC SOLUTION TIN, CODE 2090 7440-31-5
107-15-3
7732-18-5
P/N 30101006 SIFCO DALIC SOLUTION CLEANER & DEOXIDIZER 1310-73-2
7732-18-5
LEAD-ACID BATTERY 7439-92-1
7440-36-0
7440-38-2
7440-70-2
7440-31-5
7664-93-9
9003-07-4
60676-86-0
PN:75-26222-01 ANACOMP-AUTOPOS 2000 FIRST DEVELOPER 123-31-9
1310-73-2
109-83-1
PN:75-26222-02 ANACOMP-AUTOPOS 2000 SECOND DEVELOPER 123-31-9
1310-73-2
109-83-1
PN:75-272521 ANACOMP-AUTOPOS 2000 FIXER 7783-18-8
10192-30-0
PN:75-28202-00 ANACOMP-AUTOPOS 2000 ARCHIVAL WASH
PN:75-29202-00 ANACOMP-AUTOPOS 2000 FINAL WASH
SCOTCHGARD BRAND CLEANER FOR FABRIC & UPHOLSTERY,1014 7732-18-5
75-28-5
151-21-3
1643-20-5
111-76-2
25882-44-4
67-63-0
DUPONOL WA PASTE SURFACTANT 151-21-3
1191-50-0
1120-01-0
7647-14-5
7732-18-5
STIMUKIL FLY BAIT 16752-77-5
023477-000 NICKEL CADMIUM AIRCRAFT BATTERY 1313-99-1
1310-58-3
1306-19-0
7440-50-8
LITHIUM OXYHALIDE PRIMARY BATTERY (BCXII) 7439-93-2
7791-25-5
7782-50-5
P/N 34000004-2 HALON 1301 75-63-8
TADIRAN LITHIUM INORGANIC 3.6V BATTERY,SIZE AA. 7719-09-7
7439-93-2
7446-70-0
7447-41-8

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net