===================== Product Identification =====================
MSDS NAME:REGULAR CLEAR PVC SOLVENT CEMENT, 31013
NIIN:01-381-7326
MSDS Number: CGDVG
=== Responsible Party ===
Company:OATEY
Address:4700 WEST 160TH ST
Box:35906
City:CLEVELAND
State:OH
ZIP:44135
Country:US
Info Phone Num:216-267-7100
Emergency Phone Num:303-623-5716;800-424-9300(CHEMTREC)
CAGE:IO629
=== Contractor Identification ===
Company:OATEY
Address:4700 W 160TH ST
Box:35096
City:CLEVELAND
State:OH
ZIP:44135
Country:US
Phone:303-623-5716
CAGE:IO629
Company:OATEY CO
Address:4700 WEST 160TH STREET
Box:35906
City:CLEVELAND
State:OH
ZIP:44135
Country:US
Phone:216-267-7100/303-623-5716
CAGE:53472
============= Composition/Information on Ingredients =============
Name:POLYVINYL CHLORIDE
CAS:9002-86-2
RTECS #:KV0350000
Fraction by Wt: 10-14%
OSHA PEL:N/K
ACGIH TLV:N/K
Name:2-BUTANONE; (METHYL ETHYL KETONE) (SARA 313) (CERCLA)
CAS:78-93-3
RTECS #:EL6475000
Fraction by Wt: 40-55%
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/300 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:FURAN, TETRAHYDRO-; (TETRAHYDROFURAN) (CERCLA)
CAS:109-99-9
RTECS #:LU5950000
Fraction by Wt: 25-40%
OSHA PEL:200 PPM
ACGIH TLV:200 PPM/250 STEL
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:CYCLOHEXANONE (CERCLA)
CAS:108-94-1
RTECS #:GW1050000
Fraction by Wt: 5-10%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 0-5%
OSHA PEL:1000 PPM
ACGIH TLV:750 PPM/1000 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHAL: MAY CAUSE IRRIT OF
MUCOUS MEMBRANES, NOSE & THROAT, HEADACHE, DIZZ, NAUS, NUMBNESS OF
EXTREMITIES & NARCOSIS IN HIGH CONCS. HAS CAUSED CNS DEPRESS &
LIVER DAMAGE IN ANIMALS, & HIGH CONCS HAVE CAUSED RETARDATION OF
FETAL DEVELOPMENT IN RATS. SKIN: CHRONIC CONT MAY LEAD TO IRRIT &
DERM. (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: CHRONIC EXPOSURE TO VAPS OF HIGH CONC
MAY CAUSE DERMATITIS. MAY POSSIBLY BE ABSORBED THRU SKIN. EYE:
VAPORS/DIRECT CONT MAY CAUSE IRRIT. INGEST: MAY BE ASPIRATED INTO
LUNGS/CAUSE SYSTEMIC EF TS DESCRIBED UNDER INHALATION. TARGET
ORGANS: EYES, SKIN, KIDNEY, LUNG, LIVER, CENTRAL NERVOUS SYSTEM.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:SKIN:WASH THORO W/SOAP & WATER. SEEK MED ATTN IF IRRIT
PERSISTS. EYES:IF FUMES CAUSE IRRIT, MOVE TO FRESH AIR & IRRIGATE
EYES W/WATER FOR @ LST 15 MINS. IF IRRIT PERSISTS, SEEK MED ATTN.
INHAL:MOVE TO FRESH AIR. IF BRTHG IS DFCLT, GIVE OXYG. IF NOT
BRTHG, GIVE ARTF RESP. KEEP VICTIM QUIET & WARM. CALL POIS CTL
CTR/PHYS IMMED. INGEST:DRINK WATER & CALL POIS CTL CTR/PHYS IMMED.
AVOID (SUPDAT)
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:>0F,>-18C
Lower Limits:1.8%
Upper Limits:11.8%
Extinguishing Media:FOR SM FIRES: USE DRY CHEM, CO*2, WATER/FOAM
EXTING. FOR LG FIRES: EVACUATE AREA & CALL FIRE DEPARTMENT
IMMEDIATELY.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA, STOP LEAK IF IT CAN BE DONE
W/OUT RISK. TAKE UP WITH SAND, EARTH, OR OTHER NON-COMBUSTIBLE
ABSORBING MATERIAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP AWAY FROM HEAT, SPARKS AND
FLAMES; STORE IN COOL, DRY AREA.
Other Precautions:CONTAINERS, EVEN EMPTIES WILL RETAIN RESIDUE AND
VAPORS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPROVED CANNISTER RESPIRATOR IN ABSENCE
OF ADEQUATE VENTILATION.
Ventilation:GEN MECH: EXHAUST VENT CAPABLE OF MAINTAINING EMISSIONS @
POINT OF USE BELOW PEL. LOC EXHAUST: OPEN DOORS & (SUPDAT)
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
% VOLT:88+/-2%. MATLS TO AVOID:COPPER ALLOYS. FIRST AID PROC:ALCOHOLIC
BEVERAGES. NEVER GIVE ANYTHING BY MOUTH TO UNCON PERSON.
VENT:WINDOWS. IF USED IN ENCLOSED AREA, USE EXHAUST FANS.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:151F,66C
Vapor Pres:145 @ 20C
Vapor Density:2.5
Spec Gravity:0.90+/-0.015
Evaporation Rate & Reference:5.5-8.0 (BUAC =1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:CLEAR LIQUID, ETHER-LIKE ODOR.
Percent Volatiles by Volume:SUPDAT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ACIDS, OXIDIZING MATLS, ALKALIS, CHLORINATED INORGANICS (POTASSIUM,
CALCIUM & SODIUM HYPOCHLORITE), COPPER OR (SUPDAT)
Stability Condition to Avoid:HEAT, SPARKS AND OPEN FLAME.
Hazardous Decomposition Products:POTS:CARBON MONOXIDE/CARBON
DIOXIDE/HYDROGEN CHLORIDE/SMOKE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF ACCORDING TO LOCAL, STATE, AND
FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|