===================== Product Identification =====================
MSDS NAME:NUTEC SEMI PASTE PAINT AND VARNISH STRIPPER
NIIN:00N068598
MSDS Number: CGTBN
=== Responsible Party ===
Company:NUTEC INDUSTRIAL CHEMICAL CO INC
Address:15561 PRODUCT LN D-15
City:HUNTINGTON BEACH
State:CA
ZIP:92649
Country:US
Info Phone Num:800-322-0351
Emergency Phone Num:800-322-0351; 800-535-5053
CAGE:03SD1
=== Contractor Identification ===
Company:NUTEC INDUSTRIAL CHEMICAL CO INC
Address:15561 PRODUCT LN D-15
Box:City:HUNTINGTON BEACH
State:CA
ZIP:92649
Country:US
Phone:800-322-0351
CAGE:03SD1
============= Composition/Information on Ingredients =============
Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
OSHA PEL:1000 PPM
ACGIH TLV:750 PPM;1000 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:METHANOL; (METHYL ALCOHOL) (SARA 313) (CERCLA)
CAS:67-56-1
RTECS #:PC1400000
OSHA PEL:200 PPM, S
ACGIH TLV:200 PPM;250 STEL, S
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:2-BUTANONE; (METHYL ETHYL KETONE) (MEK) (SARA 313) (CERCLA)
CAS:78-93-3
RTECS #:EL6475000
OSHA PEL:200 PPM
ACGIH TLV:200 PPM;300 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:TOLUENE (SARA 313) (CERCLA)
CAS:108-88-3
RTECS #:XS5250000
OSHA PEL:200 PPM
ACGIH TLV:50 PPM, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:VOLATILE ORGANIC COMPOUNDS: 589 G/L.
RTECS #:9999999VO
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACETONE:PROLONGED OR REPEATED TOPICAL
USE MAY CAUSE EURHYTHMIA, DRYNESS. INHALATION MAY PRODUCE NARCOSIS.
METHANOL:CAUTION:POISONING MAY OCCUR FROM INGESTION, INHALATION OR
PERCUTANEOUS ABSORPTION. TO LUENE:CAUTION:NARCOTIC IN HIGH
CONCENTRATIONS. NOTE:TOLUENE APPEARS ON THE NAVY LIST OF
OCCUPATIONAL (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ:CHEMICAL REPRODUCTIVE HAZARDS. SEEK
CONSULTATION FROM APPROPRIATE HEALTH PROFESSIONALS CONCERNING
LATEST HAZARD INFO & SAFE HANDING & EXPOSURE INFO .
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . SHOULD AVOID EXPOSURE ABOVE OSHA PELS BY PROVIDING ADEQUATE
AIR MOVEMENT OR PROPER NIOSH APPROVED BREATHING APPARATUS. SKIN:FL
USH W/COPIOUS AMOUNTS OF WATER. CALL MD. EYES:AVOID CONTACT. WASH
IMMEDIATELY FOR AT LEAST 15 MINUTES, SEE MD. INGEST:INDUCE
VOMITING, SEE MD.
===================== Fire Fighting Measures =====================
Flash Point Method:OC
Flash Point:86.0F,30.0C
Lower Limits:1.5%
Upper Limits:12%
Extinguishing Media:WATER FOG, CO*2, DRY CHEMICAL ON SMALL FIRES. FOAM
FOR LARGE FIRES.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . COOL FIRE EXPOSED CONTAINERS W/WATER SPRAY TO PREVENT
PRESSURE BUILDUP.
Unusual Fire/Explosion Hazard:FLAMMABLE LIQUID; CAN BE IGNITED BY
SPARKS OR FLAME, ELECTRICAL EQUIPMENT, STATIC DISCHARGE, ETC, VAPOR
& AIR CAN FORM EXPLOSIVE MIXTURES - SEE LEL/UEL RANGE.
================== Accidental Release Measures ==================
Spill Release Procedures:IMMEDIATELY EXTINGUISH IGNITION SOURCES,
VENTILATE AREA. TAKE UP GROSS QUANTITIES W/NON-SPARKING TOOLS,
PLACE INTO APPROVED-DISPOSAL DRUM. TAKE UP RESIDUE AS INERT,
NON-FLAMMABLE ABSORBENT MATERIAL & PLACE INTO APPROVED WASTE
CONTAINER FORDISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE AWAY FROM HIGH TEMPERATURES,
OPEN FLAME, OTHER POTENTIAL IGNITION SOURCES, OUT OF DIRECT
SUNLIGHT, AWAY FROM INCOMPATIBILITIES.
Other Precautions:STORE AT TEMPERATURES <120F. AVOID SKIN & EYE
CONTACT, INGESTION, BREATHING OF VAPORS. USE W/ADEQUATE
VENTILATION. NO EATING, DRINKING OR SMOKING AT POINT OF USE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR A NIOSH APPROVED CARTRIDGE-TYPE RESPIRATOR
SPECIFIC FOR ORGANIC VAPORS. IF TLV'S ARE EXCEEDED NIOSH APPROVED
AIR SUPPLIED RESPIRATORS OR SCBA SHOULD BE WORN. NOTE:DO NOT EXCEED
MFR'S PRESCRIBED L IMITATIONS FOR RESPIRATOR TYPE.
Ventilation:LOC EXHST:AT POINTS WHERE VAPS ESCAPE TO WORKPLACE AIR.
MECH(GEN):MAINTAIN AIRBORNE LEVELS BELOW TLV'S. SPECIAL:(SUPDAT)
Protective Gloves:NEOPRENE GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPROVED EYE WASH FOUNTAIN & DELUGE
SHOWER . WEAR IMPERVIOUS APRON/OTHER PROT CLTHG TO PVNT SKIN
CONT(SUPDAT)
Work Hygienic Practices:WASH THOROUGHLY W/SOAP & WATER AFTER USE,
BEFORE EATING, DRINKING OR SMOKING, W/SOAP & WATER.
Supplemental Safety and Health
VENT:EXPLOSION-PROOF EQUIPMENT IS RECOMMENDED. OTHER PROT EQUIP:DURING
USE.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:132F,56C
Vapor Pres:27
Vapor Density:2.5
Spec Gravity:0.814 (H*2O=1)
Evaporation Rate & Reference:1.6 (BUTYL ACETATE=1)
Solubility in Water:75%
Appearance and Odor:CLEAR LIQUID; SWEET ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZERS, ACIDS, BASES.
Stability Condition to Avoid:AVOID HIGH TEMPERATURES, OPEN FLAMES,
SPARKS, OTHER POTENTIAL IGNITION SOURCES.
Hazardous Decomposition Products:CARBON OXIDE, TRACES OF FORMALDEHYDE
VAPORS, UNIDENTIFIABLE ORGANIC MATERIALS.
==================== Disposal Considerations ====================
Waste Disposal Methods:COMPLY W/ALL FEDERAL, STATE & LOCAL REGULATIONS
REGARDING DISPOSAL OF HAZARDOUS WASTE. CONSULT LOCAL AUTHORITIES
FOR PROPER DISPOSAL PROCEDURES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|