===================== Product Identification =====================
MSDS NAME:NON ACID COIL CLEANER
NIIN:00N085266
MSDS Number: CHBJL
=== Responsible Party ===
Company:MKG SALES ASSOCIATES INC
Address:409 BLOOMFIELD DR UNIT 5
City:WEST BERLIN
State:NJ
ZIP:08091
Country:US
Info Phone Num:609-753-7111
Emergency Phone Num:609-753-7111
Preparer's Name:RR
CAGE:JO005
=== Contractor Identification ===
Company:MKG SALES ASSOCIATES
Address:409 BLOOMFIELD DR UNIT 5
Box:City:BERLIN
State:NJ
ZIP:08054
Country:US
Phone:609-753-7111
CAGE:JO005
Company:MKG SALES ASSOCIATES INC
Address:130 MILLER RD
Box:City:MEDFORD
State:NJ
ZIP:08055
Country:US
Phone:609-953-4700
CAGE:045E5
============= Composition/Information on Ingredients =============
Name:ETHANOL, 2-BUTOXY-; (2-BUTOXYETHANOL)
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 5-10%
OSHA PEL:S, 50 PPM
ACGIH TLV:S, 25 PPM
Name:SILICIC ACID (H2SIO3), DISODIUM SALT; (SODIUM METASILICATE)
CAS:6834-92-0
RTECS #:VV9275000
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: REDNESS, IRRITATION.
SKIN: REDNESS, SEVERE IRRITATION. HEADACHE, NAUSEA, DIZZINESS MAY
RESULT FROM BREATHING VAPORS OR FROM ABSORPTION THROUGH SKIN.
INHALATION: IRRITATION TO MUCOUS MEMBR ANES. INGESTION: SEVERE
IRRITATION TO MUCOUS MEMBRANES. CHRONIC: ANIMAL STUDIES HAVE
CLEARLY (EFFECTS OF OVEREXPOSURE)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: DEMONSTRATED DOSE-RELATED ADVERSE
EFTS ON THE CNS, HEMATOPOIETIC TISS, BLOOD, KIDNEYS & LIVER ASSOC
W/ADMIN OF ETHYLENE GLYCOL MONOBUTYL ETHER (EGBE). (EXTRACTED FROM
DHHS (NIOSH) PUB NO. 90 -118) .
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:EYE CONT: FLUSH IMMEDIATELY WITH WATER FOR AT LEAST 15
MINUTES. IF IRRIT PERSIST, CALL PHYS. SKIN CONT: WASH WITH SOAP &
WATER. REMOVE CONTAMINATED CLOTHING & WASH BEFORE REUSE. INGEST:
DRINK LARGE QU ANTITIES OF MILK OR WATER. CALL PHYS. INHAL: REMOVE
EXPOSED PERSON TO FRESH AIR. TREAT SYMPTOMATICALLY. CALL PHYS.
===================== Fire Fighting Measures =====================
Flash Point:NONE TO BOILING
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM, WATER SPRAY.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE KNOWN.
================== Accidental Release Measures ==================
Spill Release Procedures:ABSORB LIQUID WITH SUITABLE ABSORBENT. FOR
LARGE SPILLS, ABSORB WITH SUITABLE ABSORBENT AND COLLECT FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT GET IN EYES, ON SKIN, ON
CLOTHING. AVOID BREATHING VAPOR OR MIST. KEEP CONTAINER CLOSED. USE
WITH ADEQUATE VENTILATION.
Other Precautions:KEEP OUT OF REACH OF CHILDREN.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NOT NEEDED UNDER NORMAL CONDITIONS OF USE. NIOSH
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:MECHANICAL.
Protective Gloves:RUBBER GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . MAY
BE NEEDED IF SPLASHING OR SPRAY DRIFT OCCURS.
Work Hygienic Practices:WASH THOROUGHLY AFTER HANDLING.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:212F,100C
Spec Gravity:1.040 (H*2O=1)
pH:12.5
Evaporation Rate & Reference:ABOUT THE SAME AS WATER
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, "BUTYL" ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZERS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:CARBON MONOXIDE AND OTHER UNIDENTIFIED
ORGANIC GASES MAY OCCUR DURING COMPLETE COMBUSTION.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH APPLICABLE
FEDERAL, STATE AND LOCAL ORDINANCES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|