===================== Product Identification =====================
MSDS NAME:CEILCOTE 695 CEILCRETE BASECOAT LIQUID
NIIN:00N086599
MSDS Number: CHFPR
=== Responsible Party ===
Company:MASTER BUILDERS INC
Address:23700 CHAGRIN BLVD
City:CLEVELAND
State:OH
ZIP:44122
Country:US
Info Phone Num:216-831-5500
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:FO873
=== Contractor Identification ===
Company:MARTIN MARIETTA CHEM MASTER BUILDERS DIV
Address:23700 CHAGRIN BLVD
Box:City:CLEVELAND
State:OH
ZIP:44122-5506
Country:US
Phone:216-831-5500
CAGE:98898
Company:MASTER BUILDERS DIV MARTIN MARIETTA CORP
Address:23700 CHAGRIN BLVD
City:CLEVELAND
State:OH
ZIP:44122-5506
Phone:(216) 831-5500
CAGE:FO873
============= Composition/Information on Ingredients =============
Name:STYRENE (SARA 313). BP:293F,145C. LEL:1.1%. UEL:6.1%.
LD50:(ORAL,RAT) 5000 MG/KG.
CAS:100-42-5
RTECS #:WL3675000
Fraction by Wt: 35-50%
OSHA PEL:100 PPM
ACGIH TLV:50 PPM;100 STEL, S
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Name:SUPP DATA:LEVELS MAY BE A HAZARD TO DEVELOPING EMBRYOS.
RTECS #:9999999ZZ
Name:FIRST AID PROC:WATER; GET IMMED MED ATTN. IF VOMIT OCCURS
SPONT, KEEP HEAD BELOW HIPS TO PVNT ASPIR OF LIQ INTO (ING 4)
RTECS #:9999999ZZ
Name:ING 3:LUNGS. DO NOT GIVE ANYTHING BY MOUTH TO AN
UNCONSCIOUS PERSON.
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:INHALATION:VAPORS CAN BE
IRRITATING TO NOSE & MUCOUS MEMBRANES. HIGH STYRENE EXPOSURES MAY
RESULT IN NARCOTIC EFFECT, HEADACHES AND POSSIBLE UNCONSCIOUSNESS.
EYES:CONTACT CAN CAUSE SEVERE IRRITA TION, REDNESS, TEARING,
BLURRED VISION.MAY CAUSE CORNEAL INJURY. SKIN CONTACT:PROLONGED OR
REPEATED (EFTS OF OVEREXP)
Explanation of Carcinogenicity:STYRENE:IARC MONOGRAPHS, VOL 60, PG 115,
1994:GROUP 2B. ANIMAL:REPRODUCTIVE SYSTEM.
Effects of Overexposure:HLTH HAZ:EXPOS MAY CAUSE IRRIT, REDNESS & EVEN
DMG. SKIN ABSORPTION:NO KNOWN INFO AVAIL. INGEST:INTAKE CAN CAUSE
GI IRRIT, NAUS, VOMIT, DIARR, HDCH & DROW. MAY CAUSE CHEM PNEUM IF
ASPIRATED INTO LUNGS . CHRONIC:MATLS ARE NOT KNOWN MUTAGENIC,
TERATOGENIC/REPRO HLTH HAZS. STYRENE IS NOT CONSIDERED TERATOGENIC,
(SUPP DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE VICTIM FROM EXPOS. IF DFCLTY W/BRTHG, ADMIN
OXYG. IF BRTHG HAS STOPPED ADMIN ARTF RESP, PREF MOUTH-TO-MOUTH.
SEEK MED ATTN. EYES:FLUSH W/WATER, LIFTING UPPER & LOWER LIDS OCCAS
FOR AT LST 15 MINS. SEEK MED ATTN. SKIN:REMOVE CONTAM CLTHG. WASH
THORO W/SOAP & WATER. IF IRRIT PERSISTS SEEK MED ATTN. WASH CONTAM
CLTHG BEFORE REUSE. INGEST:DO NOT INDUCE VOMIT; GIVE LG QTYS OF
(ING 3)
===================== Fire Fighting Measures =====================
Flash Point Method:PMCC
Flash Point:82.4F,28.0C
Lower Limits:SEE ING 1
Upper Limits:SEE ING 1
Extinguishing Media:CARBON DIOXIDE, FOAM, DRY CHEMICAL & WATER FOG.
Fire Fighting Procedures:USE NIOSH APPRVD SCBA & FULL PROTECTIVE
EQUIPMENT . AT HIGHER TEMP VAPS CAN CAUSE PRESS BUILD UP IN SEALED
CNTNRS. USE WATER TO COOL CNTNRS EXPOS TO FIRE.
Unusual Fire/Explosion Hazard:VAPS HVR/AIR CAN CONCENTRATE, TRAVEL TO
SOURCE OF IGNIT & FLASH BACK. RESIDUE IN CNTNR CAN IGNITE
EXPLOSIVELY. ELEC GROUNDING IS REC WHEN TRANSFERRING (SUPDAT)
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE AREA, ELIMINATE ALL SOURCES OF
IGNITION. WEAR APPROPRIATE PROTECTIVE GEAR, CONTAIN LEAK OR SPILL,
SALVAGE, CLEAN UP RESIDUE W/ABSORBENT MATERIAL. RQ: PRODUCT - 2000
LBS; STYRENE - 1000 LBS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE BELOW 70F, USE IMMEDIATELY.
Other Precautions:FLAMMABLE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WEAR NIOSH APPRVD RESP PROT WHENEVER AIRBORNE
CONCS EXCEED TLV CEILINGS/TWA, USE NIOSH APPRVD RESPS EQUIPPED
W/ORG VAP CARTRIDGE FOR LISTED HAZ. CONFINED SPACES, ROOMS/TANKS
ARE AREAS WHERE CONCERN FO R TLV'S IS ESP IMPORTANT. (SUPP DATA)
Ventilation:VENT IS REC. AIR MOVEMENT MUST BE DESIGNED TO INSURE
TURNOVER AT ALL LOCATIONS IN WORK AREA TO AVOID BUILD UP OF(SUPDAT)
Protective Gloves:RUBBER/LATEX GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EYE WASH FOUNTAIN & DELUGE
SHOWER . SELECTION OF SPECIFIC ITEMS SUCH AS BOOTS & APRON WILL
(SUPP DATA)
Work Hygienic Practices:DO NOT WEAR CONTACT LENSES WHEN WORKING W/THIS
MATERIAL.
Supplemental Safety and Health
EXPLO HAZ:MATL IN CNTNRS 1 GAL (4 LITERS) OR LGR. CNDTNS(STAB):PROD IS
NOT MIXED & USED ACCORDING TO DIRECTIONS. RESP PROT:REFERENCE OSHA
REG CFR 29 1910.134 FOR REC RESP PROT. VENT:HEAVY VAPS. OTHER PROT
EQUIP:DEPEND ON OPERATION. EFTS OFOVEREXP:ALTHOUGH A FEW ANIMAL
STUDIES INDICATED THAT EXPOS TO VERY HIGH (ING 2)
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:SEE ING 1
Vapor Pres:5 @ 20C
Vapor Density:HVR/AIR
Spec Gravity:1.04
Solubility in Water:NONE
Appearance and Odor:ORANGE LIQUID; AROMATIC SWEET ODOR.
Percent Volatiles by Volume:50
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
PEROXIDE, OXIDIZING & REDUCING AGENTS, METAL SALTS SUCH AS FERRIC &
ALUMINUM CHLORIDES.
Stability Condition to Avoid:NOT SENSITIVE TO MECH IMPACT. AVOID
EXCESSIVE CATALYST & HEAT. EXCESSIVE HEAT, FUMES & SMOKE CAN OCCUR
IF THIS (SUPDAT)
Hazardous Decomposition Products:ACRID FUMES, OXIDES OF CARBON &
NITROGEN, VARIOUS UNKNOWN HYDROCARBONS FROM INCOMPLETE COMBUSTION.
==================== Disposal Considerations ====================
Waste Disposal Methods:HANDLE DISPOSAL OF WASTE MATERIAL IN MANNER
WHICH COMPLIES W/LOCAL, STATE, PROVINCE & FEDERAL REGULATION.
LANDFILL IF SOLIDIFIED OR INCINERATION AT AGENCY APPROVED
WASTE-DISPOSAL FACILITIES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|