===================== Product Identification =====================
MSDS NAME:850 6248 ANACOMP AUTOEXCEL(R) FIXER, 1 GALLON, READY-TO-USE
NIIN:00D005797
MSDS Number: CHKVV
=== Responsible Party ===
Company:EASTMAN KODAK COMPANY
Address:343 STATE STREET
City:ROCHESTER
State:NY
ZIP:14650
Country:US
Info Phone Num:716-477-3194 MSDS :800- 242-2424
Emergency Phone Num:716-722-5151
CAGE:19139
=== Contractor Identification ===
Company:EASTMAN KODAK CO GOVERNMENT MARKETS CONTRACTS
Address:343 STATE ST
Box:City:ROCHESTER
State:NY
ZIP:14650-1115
Country:US
Phone:716-722-5151/(800) 242-2424
CAGE:19139
Company:EASTMAN KODAK CO US CUSTOMER SERVICE/GOVERNMENT SALES
Address:800 LEE RD
Box:City:ROCHESTER
State:NY
ZIP:14650-3129
Country:US
Phone:800-828-6203
CAGE:5K871
============= Composition/Information on Ingredients =============
Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 80-90%
Other REC Limits:NONE RECOMMENDED
Name:AMMONIUM THIOSULFATE
CAS:7783-18-8
RTECS #:XN6465000
Fraction by Wt: 10-15%
Other REC Limits:NONE RECOMMENDED
Name:SODIUM ACETATE
CAS:127-09-3
RTECS #:AJ4300010
Fraction by Wt: 1-5%
Other REC Limits:NONE RECOMMENDED
Name:AMMONIUM BISULFITE (CERCLA)
CAS:10192-30-0
RTECS #:WT3595000
Fraction by Wt: <1%
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:AMMONIUM ACETATE (CERCLA)
CAS:631-61-8
RTECS #:AF3675000
Fraction by Wt: <1%
Other REC Limits:NONE RECOMMENDED
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHAL:EXPECTED TO BE LOW HAZ FOR
RECOMMENDED HNDLG.CONTACT W/STRONG ACIDS/HEATED SULFITES LIBERATE
SO2 GAS-IRRIT RESP TRACT.SOME ASTHMATICS/HYPERSENS PEOPLE MAY
EXPERIENCE DIFFI BREATH.EYE:NO SPEC HAZ KNONW.MAY CAUSE TRANS
IRRIT.SKIN:HAS LOW POT TO CAUSE ALLERGIC SKIN RXS;HOEWEVER CASES OF
HUMAN SKIN SENS HAVE(SIGN/SY)
Explanation of Carcinogenicity:PER MSDS:CARCINOGENICITY
CLASSIFICATION:IARC/ACGIH/NTP/OSHA:NONE.
Effects of Overexposure:HEALTH:BEEN REPORTED.INGEST:MAY BE HARMFUL.SOME
ASTHMATICS/SULFITE-SENS INDIVIDUALS MAY EXPERIENCE WHEEZING,CHEST
TIGHTNESS,STOMACH UPSET,HIVES,FAINT,WEAK,DIARR.
SIGNS/SYMPTOMS:IRRIT RESP TRACT,TRANST EYE IRRIT,SKIN SENS,IN SOME
PEOPLER-BREATHING,WHEEZING,CHEST TIGHTNESS,STOMACH
UPSET,HIVES,FAINTNESS,WEAKNESS,DIARR.
Medical Cond Aggravated by Exposure:SOME ASTHMATICS/SULFITE SENS
INDIVIDUALS MAY EXPERIENCE WHEEZING,CHEST TIGHTNESS,STOMACH
UPSET,HIVES,FAINTNESS,WEAK,DIARR.SOME ASTHMATICS/HYPERSEN
INDIVIDUALS MAY EXPERIENCE DIFFICULT BREATHING.
======================= First Aid Measures =======================
First Aid:INHAL:SYMPTO MOVE TO FRESH AIR.TREAT SYMPTOMATIC.SYMPT
PERSIST GET MED ATTN.EYE:ANY MATL THAT CONTACT EYE SHOULD BE WASHED
OUT IMMED W/WATER.SYMPT OCCUR GET MED ATTN.SKIN:WASH
W/SOAP/WATER.SYMPT OCCUR GET MED ATTN.INGEST:DRINK 1-2 GLASSES OF
WATER.SEEK MED ATTN.NEVER GIVE ANYTHING BY MOUTH IF UNCONSC.
===================== Fire Fighting Measures =====================
Flash Point:NONE
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NP
Upper Limits:NP
Extinguishing Media:USE APPROPRIATE AGENT FOR ADJACENT FIRE.
Fire Fighting Procedures:WEAR SELF CONTAINED BREATHING APPARATUS AND
PROTECTIVE CLOTHING.FIRE OR EXCESSIVE HEAT MAY PRODUCE HAZARDOUS
DECOMPOSITION PRODUCTS.
Unusual Fire/Explosion Hazard:NONE. NON-COMBUSTIBLE LIQUID.
================== Accidental Release Measures ==================
Spill Release Procedures:FLUSH TO SEWER W/LG AMTS OF WATER.OTHERWISE
ABSORB SPILL W/VERMICULITE OR OTHER INERT MATL,THEN PLACE IN
CONTAINER FOR CHEMICAL WASTE.CLEAN SURFACE THOROUGHLY TO REMOVE
RESIDUAL CONTAMINATION.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID BREATH MIST/VAP.AVOID EYE
CONTACT/PROL/REP SKIN CONTACT.USE W/ADEQU VENTI.KEEP FROM CONTACT
W/OXIDI MATLS.KEEP CNTNR TIGHTLY CLOSED.
Other Precautions:KEEP AWAY FRM INCOMPA SUBST.MATL ACIDIC AQU
SOLN.PROPERTIES:MOD BIOCHEM OXY DEMAND,MAY CAUSE OXY DEPLETION IN
AQU SYS,MOD POT TO AFFECT SOME AQUATIC ORG,LOW POT TO AFFECT 2ND
WASTE TREAT MICROBIAL MET ABOLISM,LOW POT TO AFFECT GERM/(SUPPLE)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:RESPI SHOLD BE WORN IF HAZ DECOMPO PROD LIKELY
TO BE OR HAVE BEEN RELEASED.RESP TYPE:ACID GAS OR ORANIC VAPOR.IF
RESP ARE USED PROGRAM SHOULD BE INSTITUTED TO ASSURE COMPLIANCE
W/OSHA STD 29CFR1910.13 4.
Ventilation:GOOD GENERAL VENTILATION(TYP 10AIR CHANG/HR)SHOULD BE
USED.VENTILATION RATES SHOULD BE MATCHED TO CONDITIONS.
Protective Gloves:IMPERV GLOVES
Eye Protection:SAF GLASSESS W/SIDE SHIELD (OR GOGGLES)
Other Protective Equipment:EYE BATH,WASHING FACILITIES,SAFETY SHOWER.
Work Hygienic Practices:WASH THOROUGHLY AFT HNDLG.GOOD INDUSTRIAL
HYGIENE PRACT TO MIN SKIN & EYE CONTACT.
Supplemental Safety and Health
KEY1:HCC=N1. OTHER PRECAUT:EARLY GROWTH OF SOME PLANTS,LOW POT TO
BIOCONCEN.DIL W/LG AMT OF WATER MATL RELEASED DIRECTLY/INDIRECTLY
INTO ENVIRO NOT EXPECTED TO HAVE SIGNIF IMPACT.
================== Physical/Chemical Properties ==================
HCC:B1
Boiling Pt:B.P. Text:>212F,>100C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:18MM @ 20C
Vapor Density:0.6
Spec Gravity:1.07
pH:5.1
Viscosity:NP
Evaporation Rate & Reference:NP
Solubility in Water:COMPLETE
Appearance and Odor:LIQUID, COLORLESS, VINEGAR ODOR
Percent Volatiles by Volume:80-90
Corrosion Rate:NP
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS,BASES,STRONG OXIDZING AGENTS,SODIUM
HYPOCHLORITE(BLEACH).CONTACT W/BASE LIBERATES FLAMM MATL.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:HAZ COMBUST PROD:NONE. HAZ DECOMPO
PRODS:SULFUR DIOXIDE, NITROGEN OXIDES (NOX), AMMONIA, CHLORAMINE.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISCHARGE/TREAT/DISPO MAY BE SUBJ TO
NAT/STATE/LOC LAWS.FLUSH TO SEWERS W/LG AMTS OF WATER.CHEMS SUBJ TO
SEC 313 TITLE III SARA/40CFR372:NONE.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|