===================== Product Identification =====================
MSDS NAME:TT-P-86 TV 1 RED LEAD PRIMER
NIIN:00-297-2135
Status Code:A
MSDS Number: CKQWG
=== Responsible Party ===
Company:JORDAN PAINT MFG CO INC
Address:7250 FRANKLIN ST
City:FOREST PARK
State:IL
ZIP:60130-1162
Country:US
Info Phone Num:708-366-8171
Emergency Phone Num:312-366-8171
Preparer's Name:DR
CAGE:28194
=== Contractor Identification ===
Company:JORDAN PAINT MFG CO INC
Address:7250 FRANKLIN ST
Box:City:FOREST PARK
State:IL
ZIP:60130-1162
Country:US
Phone:708-366-8171
CAGE:28194
============= Composition/Information on Ingredients =============
Name:97% RED LEAD
CAS:1314-41-6
RTECS #:OG5425000
= Wt:78.
OSHA PEL:.05 MG/M3
ACGIH TLV:.03 MG/M3
Name:PETROLEUM SOLVENT/MINERAL SPIRITS
CAS:8032-32-4
RTECS #:OI6180000
= Wt:5.
OSHA PEL:500 PPM
ACGIH TLV:100 PPM
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SHORT -TERM HIGH-LEVEL EXPOSURE MAY BE
POISONOUS. KIDNEY DAMAGE MAY OCCUR WITHOUT SYMPTOMS.
Effects of Overexposure:INHALATION: DIZZINESS, BREATHING DIFFICULTY AND
LOSS OF COORDINATION. EYE CONTACT: SEVERE IRRITATION, TEARING,
REDNESS AND BLURRING. SKIN CONTACT: CAN DRY AND DEFAT SKIN CAUSING
CRACKS, IRRITATION A ND DERMATITIS. INGESTION: CAN CAUSE
GASTROINTESTINAL IRRITATION, VOMITING, NAUSEA AND DIARRHEA. MAY
INCLUDE TIREDNESS, DECREASED APPETITE, METALLIC TASTE, AND STOMACH
CRAMPS RESEMBLING COLIC (INTERM ITTENT RATHER THAN CONTINUOUS
PAIN). DEPENDING ON INDIVIDUAL SUSCEPTABILITY AND DEGREE OF OVER
EXPOSURE, EFFECTS ARE GENERALLY SEEN ONLY AFTER LONG-TERM EXPOSURE.
Medical Cond Aggravated by Exposure:MORE SEVERE SYMPTOMS COULD INCLUDE
TRUE MUSCLE WEAKNESS, INTENSE HEADACHES AND ON RARE OCCASIONS
CONVULSIONS OR DEATH.
======================= First Aid Measures =======================
First Aid:INHALATION OVEREXPOSURE: MOVE PERSON TO FRESH AIR. IF
BREATHING STOPS, APPLY ARTIFICIAL RESPIRATION AND SEEK IMMEDIATE
MEDICAL ATTENTION. EYE CONTACT: FLUSH WITH LARGE QUANTITIES OF
WATER FOR 15 MIN UTES. SKIN CONTACT: WASH THOROUGHLY WITH SOAP AND
WATER AND SEE A DOCTOR. INGESTION: DO NOT INDUCE VOMITING, CAN
CAUSE CHEMICAL PNEUMONITIS AND PULMONARY EDEMA. CONTACT PHYSICIAN
IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:TCC
Flash Point:=42.2C, 108.F
Lower Limits:0.9%
Upper Limits:7.0%
Extinguishing Media:FOAM, CO2, DRY CHEMICAL, WATER FOG
Fire Fighting Procedures:ALL PROTECTIVE EQUIPMENT INCLUDING
SELF-CONTAINED BREATHING APPARATUS IS RECOMMENDED TO PROTECT
FIREFIGHTERS FROM ANY HAZARDOUS COMBUSTION BY-PRODUCTS. A STRAIGHT
WATER STREAM MAY SPREAD FIRE.
Unusual Fire/Explosion Hazard:EXPOSURE TO EXTREME HEAT MAY CAUSE
PRESSURE BUILD UP IN CLOSED CONTAINERS. A VAPOR ACCUMULATION MAY
FLASH OR EXPLODE IF IGNITED.
================== Accidental Release Measures ==================
Spill Release Procedures:VENTILATE CLOSED AREAS AND REMOVE ALL IGNITION
SOURCES. WIPE UP IMMEDIATELY AND SAFELY DISCARD ABSORBENTS. FOR
LARGE SPILLS, DIKE THE AREA AND PUMP MATERIAL TO WASTE CONTAINER
WITH PROPERLY GROUNDED EQUIPMENT. OBEY REVELANT LAWS.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE NON SPARKING UTENSILS WHEN
HANDLING THIS MATERIAL. AVOID HOT METAL SURFACES. USE IN COOL,
WELL VENTILATED AREAS. KEEP CONTAINERS CLOSED WHEN NOT IN USE.
KEEP AWAY FROM HEAT AND OPEN FLAMES.
Other Precautions:SMOKING IN AREA WHERE THIS MATERIAL IS USED SHOULD BE
STRICTLY PROHIBITED. TOOLS USED WITH THIS MATERIAL SHOULD BE MADE
FROM ALUMINUM,BRASS OR COPPER. PLASTIC UTENSILS SHOULD NOT BE USED.
REPORTS HAVE ASSOCIATED REPEATED AND PROLONGED OCCUPATIONAL
OVEREXPOSURE TO SOLVENTS WITH PERMANENT BRAIN AND NE RVOUS SYSTEM
DAMAGE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:WHEN SPRAYING THIS MATERIAL USE A NIOSH APPROVED
CARTRIDGE RESPIRATOR OR GAS MASK SUITABLE TO KEEP AIRBORNE MISTS OR
VAPOR CONCENTRATIONS BELOW THE TIME WEIGHTEDTHRESHOLD LIMIT VALUES.
WHEN USING IN POORLY VENTILATED AND CONFINED SPACES USE A FRESH
AIR SUPPLYING RESPIRATOR OR A SELF CONTAINED BREATHING APPARATUS.
Ventilation:GENERAL MECHANICAL VENTILATION OR LOCAL EXHAUST SHOULD BE
SUITABLE TO KEEP VAPOR CONCENTRATION BELOW TLV. VENTILATION
EQUIPMENT SHOULD BE EXPLOSION PROOF.
Protective Gloves:IMPERMABLE CHEMICAL HANDLING GLOVES FOR SKIN
PROTECTION.
Eye Protection:USE CHEMICAL SAFETY GLASSES, GOGGLES AND FACE SHIELDS
FOR EYE PROTECTION.
Other Protective Equipment:USE IMPERMEABLE APRONS AND PROTECTIVE
CLOTHING WHENEVER POSSIBLE TO PREVENT SKIN CONTACT. THE USE OF
HEAD CAPS WHENEVER POSSIBLE IS STRONGLY RECOMMENDED.
Work Hygienic Practices:EYE WASHES AND SAFETY SHOWERS IN THE WORKPLACE
IS RECOMMENDED.
Supplemental Safety and Health
================== Physical/Chemical Properties ==================
Boiling Pt:=193.9C, 381.F
Vapor Density:>AIR
Spec Gravity:3.0
VOC Pounds/Gallon:207
VOC Grams/Liter:1.73
Evaporation Rate & Reference:SLOWER THAN ETHER
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND IGNITION
SOURCES.
=================== Toxicological Information ===================
Toxicological Information:LEAD CROSSES THE PLACENTA. FETAL EXPOSURE
SHOULD BE KEPT WITHIN CDC GUIDELINES- 10UG/100G OF BLOOD. POTENTIAL
LUNG HEALTH HAZARD MAY EXIST WHEN CHROMATE PIGMENT AIRBORNE DUST
LEVELS EXCEED REGULATIONS .
==================== Disposal Considerations ====================
Waste Disposal Methods:COLLECT ABSORBENT/WATER/SPILLED LIQUID MIXTURE
INTO METAL CONTAINERS AND ADD ENOUGH WATER TO COVER. CONSULT LOCAL
AND FEDERAL HAZARDOUS WASTE REGULATIONS BEFORE DISPOSING INTO
APPROVED HAZARDOUS WAST E LANDFILLS. OBEY RELEVANT LAWS.
===================== Regulatory Information =====================
SARA Title III Information:97% READ LEAD CAS# 1314-41-6
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|