===================== Product Identification =====================
MSDS NAME:ETERNACELL LITHIUM SDX
NIIN:01-160-3873
Status Code:A
MSDS Number: CLNCK
=== Responsible Party ===
Company:HAWKER ETERNACELL, INC.
Address:495 BOULEVARD
City:ELMWOOD PARK
State:NJ
ZIP:07407-2029
Country:US
Info Phone Num:201-796-4800 /FAX: 201-796-6243
Emergency Phone Num:(800)424-9300
Preparer's Name:K. ERRICKSON
Chemtrec Ind/Phone:(800)424-9300
CAGE:5G978
=== Contractor Identification ===
Company:HAWKER ETERNACELL, INC.
Address:495 BOULEVARD
Box:City:ELMWOOD PARK
State:NJ
ZIP:07407-2029
Country:US
Phone:201-796-4800 /FAX: 201-796-6243
CAGE:5G978
Company:NORTH AMERICAN TRADE CORP
Address:13901 HWY 105 W
Box:City:CONROE
State:TX
ZIP:77304
Country:US
Phone:936-588-8006
Contract Num:SP0430-01-M-FT56
CAGE:9X121
============= Composition/Information on Ingredients =============
Name:SULFUR DIOXIDE
CAS:7446-09-5
RTECS #:WS4550000
OSHA PEL:13 MG/M3;5 PPM
ACGIH TLV:5.2 MG/M3;2 PPM
ACGIH STEL:13 MG/M3;5 PPM
Name:LITHIUM METAL
CAS:7439-93-2
RTECS #:OJ5540000
OSHA PEL:NA
ACGIH TLV:NA
Name:PROPYLENE
CAS:115-07-1
RTECS #:UC6740000
OSHA PEL:NE
ACGIH TLV:NE
Name:ACETONITRILE
CAS:75-05-8
RTECS #:AL7700000
OSHA PEL:67 MG/M3
ACGIH TLV:101 MG/M3
ACGIH STEL:101 MG/M3;60 PPM
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS
Name:LITHIUM SLATS MIXTURE
OSHA PEL:NE
ACGIH TLV:NE
Name:STEEL CASING & NON-HAZARDOUS COMPONENTS
OSHA PEL:NE
ACGIH TLV:NE
Name:TEFLON
CAS:9002-84-0
RTECS #:KX4025000
OSHA PEL:15 MG/M3
ACGIH TLV:NE
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ROUTE OF ENTRY: ELECTROLYTE:
INHALATION, DERMAL, INGESTION. RISK ONLY OCCURS IF CELL VENTS OR
IS OPENED. ACUTE: ELECTROLYTE IS SEVERE IRRITANT. INTACT LITHIUM IS
REACTIVE, WITH MOISTURE. AVOID CONTAC T. CHRONIC: MAY CAUSE
DERMATITIS. SOME COMPONENTS HAVE BEEN SHOWN TO BE TERTAOGENIC TO
ANIMALS. AVOID CONTACT.
Effects of Overexposure:EXPOSURE TO SKIN OR EYES MAY CAUSE IRRITATION.
INHALATION MAY RESULT IN DIFFICULTY BREATHING
Medical Cond Aggravated by Exposure:UNKNOWN.
======================= First Aid Measures =======================
First Aid:EYE: FLUSH WITH WATER FOR 15 MINUTES. SEEK MEDICAL
ASSISTANCE. SKIN: FLUSH WITH WATER FOR 15 MINUTES. SEEK MEDICAL
ASSISTANCE. INHALATION: REMOVE TO FRESH AIR. SEEK MEDICAL
ASSISTANCE
===================== Fire Fighting Measures =====================
Flash Point:NA, AVOID > 185F
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:LITH-X, DRY SAND, DRY POWDERED GRAPHITE.
Fire Fighting Procedures:COVER BATTERY WITH EXTINGUISHING MEDIA, ALLOW
TO COOL, REMOVE ADJACENT COMBUSTIBLE MATERIALS IF SAFE TO DO SO.
SCBA REQUIRED.
Unusual Fire/Explosion Hazard:DO NOT USE WATER TO EXTINGUISH FIRES,
CELLS CAN REACT WITH WATER VOILENTLY. CELLS CAN VENT ELECTROLYTE IF
SUBJECTED TO TEMPERATURES OF 185 DEG F OR GREATER. HEATING ABOVE
354 DEG F WILL LEAD TO MELTIN G OF LITHIUM AND REPRESENTS A SEVERE
FIRE AND EXPLOSION HAZARD.
================== Accidental Release Measures ==================
Spill Release Procedures:ALLOW BATTERY TO COOL AND VAPOR TO DISSIPATE.
AVOID CONTACT. AVOID INHALATION OF VAPORS. REMOVE SPILLED
ELECTROLYTE WITH ABSORBENT MATERIAL. WEAR FULL-FACE ACID/ORGANIC
CARTRIDGE RESPIRATOR.
====================== Handling and Storage ======================
Handling and Storage Precautions:BATTERIES MAY EXPLODE, IGNITE, OR VENT
ELECTROLYTE IF CRUSHED, OPENED, PUNCTURED, OR EXPOSED TO
TEMPERATURES IN EXCESS OF 185 DEG F. DO NOT SHORT CIRCUIT, INSTALL
WITH INCORRECT POLARITY, OR ATTEMPT T O RECHARGE. DO NOT
INCINERATE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE FULL-FACE ACID/ORGANIC VAPOR RESPIRATOR IF
CELL VENTS. USE SCBA IF LARGE NUMBERS OF CELLS VENT SIMULTANEOUSLY.
Ventilation:PROVIDE IF CELL VENTS.
Protective Gloves:NATURAL OR BUTYL RUBBER GLOVES.
Eye Protection:CHEMICAL GOGGLES.
Other Protective Equipment:USE ENCAPSULATING SUIT IF FIRE OCCURS.
Work Hygienic Practices:AVOID EXPOSURE. WASH HANDS AFTER HANDLING.
Supplemental Safety and Health
IDENTITY: LITHIUM/SULFUR DIOXIDE CELLS & BATTERIES. TRADE NAME:
ETERNACELL LITHIUM SDX.
================== Physical/Chemical Properties ==================
HCC:Z6
Boiling Pt:B.P. Text:NA
Vapor Pres:NA
Vapor Density:NA
Spec Gravity:NA
pH:NOT PROVIDED
Evaporation Rate & Reference:NA
Solubility in Water:DO NOT EXPOSE TO WATER
Appearance and Odor:APPEARANCE OF SMALL BATTERY, CYLINDRICAL OR
BOXLIKE. ODOR: NONE
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
DO NOT EXPOSE TO WATER.
Stability Condition to Avoid:DO NOT HEAT ABOVE 185 DEG F, PUNCTURE,
OPEN CELL, SHORT CIRCUIT, OR ATTEMPT TO RECHARGE.
Hazardous Decomposition Products:MAY INCLUDE CARBON MONOXIDE AND
CAUSTIC LITHIUM OXIDE.
Conditions to Avoid Polymerization:WILL NOT OCCUR
==================== Disposal Considerations ====================
Waste Disposal Methods:FULLY DISCHARGE PRIOR TO DISPOSAL. DISPOSE OF IN
ACCORDANCE WITH LOCAL, STATE, AND FEDERAL REGULATIONS.
=================== MSDS Transport Information ===================
Transport Information:APPLICABLE REGULATIONS: 49 CFR 172.101, 173, 185,
IATA. PROPER SHIPPING NAME: LITHIUM BATTERY. CLASS: 9. UN ID NO.:
UN3090. PACKING GROUP: II. LABEL: CLASS 9. EXCEPTION: LITHIUM CELLS
AND BATTERIES CO NTAINING NO MORE THAN 1.0G LITHIUM ARE NOT SUBJECT
TO 49 CFR 173.185.
======================================================================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|