Search   
MSDS  
:
 FP-93 A PENETRANT
CAS  
:
 64742-46-7
NAME  
:
 hydrotreated middle petroleum distillate/petroleum
=====================  Product Identification  =====================

MSDS NAME:FP-93 A PENETRANT
NIIN:00-782-2732
MSDS Number: BFPLW
=== Responsible Party ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID ST
City:SANTA MONICA
State:CA
ZIP:90404
Country:US
Info Phone Num:310-450-1111
Emergency Phone Num:310-450-1111/800-424-9300(CHEMTREC)
CAGE:98733
=== Contractor Identification ===
Company:MET-L-CHEK COMPANY
Address:1639 EUCLID ST
Box:00000
City:SANTA MONICA
State:CA
ZIP:90404
Country:US
Phone:310-450-1111/FAX 310452-4046
CAGE:98733

=============  Composition/Information on Ingredients  =============

Name:HYDROTREATED MIDDLE PETROLEUM DISTILLATE/PETROLEUM
    HYDROCARBON,SEVERELY HYDROTREATED MIDDLE DISTILLATE
CAS:64742-46-7
RTECS #:JN9379645
Other REC Limits:NONE RECOMMENDED
OSHA PEL:5 MG/M3 AS OIL MIST
ACGIH TLV:5 MG/M3 AS OIL MIST

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 (ORAL, RAT) IS NOT KNOWN.
Routes of Entry: Inhalation:NO	Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS:EYES, SKIN, RESPIRATORY
    AND GASTROINTESTINAL TRACTS. ACUTE- EYES/SKIN:MAY CAUSE SLIGHT
    IRRITATION. INHALE:VAPORS OR OIL MIST MAY CAUSE MILD IRRITATION TO
    UPPER RESPIRATORY TRACT. ORAL:IN GESTION MAY CAUSE VOMITING.
    ASPIRATION HAZARD. CHRONIC- UNKNOWN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:IRRITATION, NAUSEA, VOMITING
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING
    DISEASES OF THE EYE, SKIN, RESPIRATORY TRACT MAY HAVE INCREASED
    SUSCEPTIBILITY TO THE TOXICITY OF EXCESSIVE EXPOSURES.

=======================  First Aid Measures  =======================

First Aid:CALL PHYSICIAN IF SYMPTOMS PERSIST. EYE:FLUSH WITH PLENTY OF
    WATER. HOLD EYELIDS OPEN. SKIN:FLUSH WITH WATER & WASH SKIN WITH
    SOAP & WATER. INHALED:REMOVE TO FRESH AIR. PROVIDE CPR/OXYGEN IF
    NEEDED. O RAL:DO NOT INDUCE VOMITING. CALL A PHYSICIAN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:210F,99C
Extinguishing Media:USE WATER FOG, CARBON DIOXIDE, FOAM/DRY CHEMICAL.
    DO NOT USE DIRECT STREAM OF WATER. COOL FIRE EXPOSED CONTAINER
    W/WATER
Fire Fighting Procedures:DO NOT ENTER ANY ENCLOSED OR CONFINED AREA
    WITHOUT PROPER PROTECTIVE EQUIPMENT AND NIOSH-APPROVED
    SELF-CONTAINED BREATHING APPARATUS. DO NOT BURN UNLESS HEATED.
Unusual Fire/Explosion Hazard:NONE

==================  Accidental Release Measures  ==================

Spill Release Procedures:PREVENT SKIN AND EYE CONTACT. ABSORB SPILLS
    WITH INERT MATERIAL SUCH AS SAND OR VERMICULITE. TRANSFER TO
    SUITABLE CONTAINERS FOR DISPOSAL. CLEAN SPILL AREA AFTER PICK UP IS
    COMPLETE.
Neutralizing Agent:NOT RELEVANT

======================	Handling and Storage  ======================

Handling and Storage Precautions:STORE AWAY FROM OPEN FLAMES AND
    OXIDIZING AGENTS.
Other Precautions:WASH THOROUGHLY WITH SOAP AND WATER AFTER HANDLING
    AND BEFORE EATING, DRINKING, SMOKING. KEEP OUT OF REACH OF
    CHILDREN. DO NOT INGEST. AVOID EYE AND SKIN CONTACT.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF TLV IS EXCEEDED OR FOR SYMPTOMS OF OVER
    EXPOSURE, WEAR NIOSH-APPROVED RESPIRATOR.
Ventilation:LOCAL EXHAUST IS RECOMMENDED FOR CONFINED AREAS. GENERAL
    MECHANICAL VENTILATION IS ADEQUATE FOR NORMAL USE.
Protective Gloves:RUBBER RECOMMENDED
Eye Protection:SAFETY GLASSES/GOGGLES RECOMMENDED
Other Protective Equipment:EYE WASH STATION, SAFETY SHOWER, PROTECTIVE
    CLOTHING
Work Hygienic Practices:OBSERVE GOOD INDUSTRIAL HYGIENE PRACTICES AND
    RECOMMENDED PROCEDURES.
Supplemental Safety and Health
FORMULA CHANGED. FOR PREVIOUS FORMULATION, SEE PNI A, SAME NSN.

==================  Physical/Chemical Properties  ==================

HCC:N1
NRC/State Lic Num:NOT RELEVANT
Boiling Pt:B.P. Text:>400F,>204C
Melt/Freeze Pt:M.P/F.P Text:-75F,-59C
Spec Gravity:0.86
Solubility in Water:INSOLUBLE
Appearance and Odor:YELLOW-GREEN LIQUID, SLIGHT HYDROCARBON ODOR

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZING AGENTS
Stability Condition to Avoid:EXCESSIVE HEAT, OPEN FLAME
Hazardous Decomposition Products:MAY FORM CARBON MONOXIDE, CARBON
    DIOXIDE, SMOKE AND OTHER UNIDENTIFIED ORGANIC COMPOUNDS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
    AND FEDERAL REGULATIONS. PLACE IN APPROPRIATE DISPOSAL FACILITY.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
D-70 DEVELOPER 67-63-0
14807-96-6
MIL-I-25135,INSPECTION MATERIAL,PENETRANT
D-70 DEVELOPER 67-63-0
14807-96-6
FLUORO FINDER FL-2 8030-30-6
63-74-1
ZL-2A ZYGLO PENETRANT (PRE NOV 86) 68477-31-6
8008-20-6
206-44-0
ZL-2C ZYGLO PENETRANT 68477-31-6
8008-20-6
ZL-2D ZYGLO PENETRANT 64742-46-7
8008-20-6
68477-31-6
VP-131 PENETRANT(PRE 10/86) SEE SUPPL DATA
FP-93 A PENETRANT 64742-46-7
DP50 DYE PENETRANT
VP-30 PENETRANT
SKL-HF/SKL-S SPOTCHECK PENETRANT(PRE MAY86) 91-20-3
SKL-LO SPOTCHECK PENETRANT(LOW ODOR)POST 86 68477-31-6
64771-72-8
91-20-3
VP-31 PENETRANT(PRE 10/86)
VP-31A PENETRANT (POST 10/86) 64742-46-7
FLUORO-FINDER FL-17A PENETRANT (NSN CANCLD) 64742-94-5
117-81-7
206-44-0
FLUORO FINDER
ZL-15 ZYGLO PENETRANT (PRE 9/1985)NSN CNCLD
ZL-15B ZYGLO WATER WASH PENETRNT(POST 9/85) 64742-46-7
8008-20-6
64742-52-5
TURCO FLURO CHECK WP-1 PENETRANT 8002-05-9
FP-90 PENETRANTL
FLUORO-FINDER FL-22A PENETRANT (POST 3/84) 64742-94-5
117-81-7
206-44-0
URESCO 149A
ZL-22A ZYGLO PENETRANT (PRE 11/86)
ZL-22D ZYGLO PENETRANT (POST 11/86) 64742-46-7
8008-20-6
68477-31-6
ZL-27A ZYGLO PENETRANT 64742-46-7
8008-20-6
68477-31-6
FP-95 A PENETRANT 64742-46-7
FLUORO-FINDER EMULSIFIER FE-5 (PRE 12/88) 64742-06-9
71-55-6
TRACER TECH E-153 111-76-2
FLUORO FINDER FE-5 8030-30-6
71-43-2
ZE-3 ZYGLO EMULSIFIER (PRE 5/86) 8012-95-1
ZE-3 ZYGLO EMULSIFIER (POST 5/1986) 8012-95-1
ZE-4B ZYGLO EMULSIFIER 64742-52-5
98-55-5
TURCO FLURO-CHEK E EMULSIFIER
E-57 EMULSIFIER 64741-96-4
ZE-3 ZYGLO EMULSIFIER 8012-95-1
ZE-4B ZYGLO EMULSIFIER 64742-52-5
98-55-5
E-50 EMULSIFIER REMOVER 64742-88-7
64742-95-6
E-56 EMULSIFIER
RC65 FLUORESCENT PENETRANT 75-28-5
DR61 CLEANER/REMOVER 71-55-6
106-88-7
123-91-1
75-52-5
75-28-5
D100NF (D101NF) DEVELOPER 71-55-6
75-28-5
D100 DEVELOPER & D350 DEVELOPER 67-63-0
14807-96-6
75-28-5
FP-30 PENETRANT
TRACER TECH P149 INSPECTION PENETRANT 206-44-0
75-45-6
115-10-6
TRACER TECH P149 INSPECT PENETRANT REMOVER 71-55-6
124-38-9
75-45-6
115-10-6
TRACER TECH P149 INSPECT PENETRANT DEVELOPE 71-55-6
75-09-2
ZL-22A ZYGLO PENETRANT(PRE 1/87-SEE SUPPL) 124-38-9
SKC-NF/ZC-7 CLEANER (PRE 1/87-SEE SUPPL) 71-55-6
124-38-9
75-28-5
ZP-9B ZYGLO DEVELOPER (PRE 10/82-SEE SUPPL) 71-55-6

Free MSDS Search ( Providing 250,000+ Material Properties )