 FLUORO-FINDER FL-17A PENETRANT (NSN CANCLD)
CAS  
:
 64742-94-5
117-81-7
206-44-0
NAME  
:
 heavy aromatic naphtha (aromatic hydrocarbons solvent, per
di-sec-octyl phthalate (di-2-ethylhexyl-phthalate) (sara
fluoranthene (sara iii)
=====================  Product Identification  =====================

MSDS NAME:FLUORO-FINDER FL-17A PENETRANT (NSN CANCLD)
NIIN:00-782-2735
MSDS Number: BFPMF
=== Responsible Party ===
Company:AMERICAN GAS AND CHEMICAL CO.LTD.
Address:220 PEGASUS AVENUE
City:NORTHVALE
State:NJ
ZIP:07647-1904
Country:US
Info Phone Num:201-767-7300
Emergency Phone Num:201-767-7300
CAGE:03530
=== Contractor Identification ===
Company:AMERICAN GAS AND CHEMICAL COMPANY,LTD
Address:220 PEGASUS AVENUE,
City:N0RTHVALE
State:NJ
ZIP:07647-1904
Country:US
Phone:201-767-7300
CAGE:03530

=============  Composition/Information on Ingredients  =============

Name:HEAVY AROMATIC NAPHTHA (AROMATIC HYDROCARBONS SOLVENT, PER
    MSDS)
CAS:64742-94-5
Fraction by Wt: 38.0%

Name:DI-SEC-OCTYL PHTHALATE (DI-2-ETHYLHEXYL-PHTHALATE)	(SARA
    III)
CAS:117-81-7
RTECS #:TI0350000
Fraction by Wt: 10.0%
OSHA PEL:5 MG/M3/10 STEL
ACGIH TLV:5 MG/M3; 9192
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

Name:FLUORANTHENE  (SARA III)
CAS:206-44-0
RTECS #:LL4025000
Fraction by Wt: 2.0%
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:NO	Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:YES    IARC:UNKNOWN    OSHA:YES
Explanation of Carcinogenicity:DI(2-ETHYLHEXYL)PHTHALATE IS LISTED AS
    INDIRECT CARCINOGEN BY NIOSH AND NTP.
Effects of Overexposure:EYE:IRRITATTING; SKN:CAUSES
    IRRITATION,DEFATTING,DERMATITIS; INHALATION:VAPOR CAUSES IRRITATION
    TO REPIRATORY TRACT,DIZZINESS,AND EFFECTS CNS; INGESTION:CAUSES
    VOMITING;POSSIBLE CHEM PNEUMONITIS.
Medical Cond Aggravated by Exposure:NONE KNOWN

=======================  First Aid Measures  =======================

First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING GIVE CPR; IF
    BREATHING DIFFICULT GIVE OXYGEN. EYE:IMMEDIATELY FLUSH WITH PLENTY
    OF WATER. SKIN:WASH WITH SOAP & WATER.REMOVE CONTAMINATED CLOTHING
    & SHOES;  INGESTION: DO NOT INDUCE VOMIT. NOTHINGBY MOUTH IF VICTIM
    IS UNCONSCIOUS.GET MEDICAL HELP.

=====================  Fire Fighting Measures  =====================

Flash Point Method:COC
Flash Point:150F/66C
Lower Limits:0.8
Upper Limits:6.0
Extinguishing Media:FOAM,DRY CHEMICAL,CO*2.WATER SPRAY OR FOG.
Fire Fighting Procedures:COOL WITH WATER SPRAY.USE SCBA WITH FULL
    PROTECTION.
Unusual Fire/Explosion Hazard:USE REASONABLE CARE.AVOID STORING WITH
    STRONG OXIDANTS,LIQUID CHLORINE OR CONC.O*2.

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE IGNITION SOURCES. RECOVER FREE LIQUID.
    COLLECT SPILL W/ABSORBENT & PLACE IN CLOSED CONTAINERS.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTAINERS CLOSED. STORE IN COOL
    AREA AWAY FROM HEAT & IGNITION SOURCES.GROUND LIQUID XFER SYSTEMS
    PER NFPA PETROLEUM STANDARDS.
Other Precautions:COMBUSTIBLE LIQUID.HANDLE EMPTY CONTAINERS WITH
    CARE.DO NOT CLEAN EMPTIES,RETURN TO DRUM RECONDITIONER, OR DISPOSE
    SAFELY IAW ALL LAWS/REGS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE SAPP RESPIRATOR AS REQD IN CONFINED SPACES
Ventilation:USE HOOD FACE VEL >60 FPM.
Protective Gloves:CHEM RESIST
Eye Protection:GOGGLES OR FACE SHIELD
Other Protective Equipment:CHEM RESIST APRON OR IMPERV CLOTHING
Supplemental Safety and Health
I/A/W QPL-25135-13 OF MIL-I-25135,REV C, ITEM WAS OF GROUP IV WHICH NO
    LONGER QUALIFIES FOR QPL-25135-15 UNDER REV E OF MIL-I-25135; HENCE
    EFFECTIVE 89121, NSN HAS BEEN CANCELLED AND REPLACED BY 6850-
    01-263-4055;UPDATE PER OSHA MSDS DTD 17JUN86.

==================  Physical/Chemical Properties  ==================

HCC:V4
Boiling Pt:B.P. Text:360F
Vapor Pres:<10
Vapor Density:4.8
Spec Gravity:0.92
Evaporation Rate & Reference:<0.1 (N-BUAC=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW-GREEN LIQUID;MILD,AROMATIC ODOR.
Percent Volatiles by Volume:38

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE SPECIFIED BY THE MFR
Hazardous Decomposition Products:CARBON MONOXIDE IN CASE OF INCOMPLETE
    COMBUSTION

====================  Disposal Considerations  ====================

Waste Disposal Methods:INCINERATE IN APPROVED FACILITY I/A/W ALL
    APPLICABLE FEDERAL,STATE, AND LOCAL LAWS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.

*** END OF RECORD ***
Search More   
ALL PAGES On Chemical Property IN THIS GROUP
NAMECAS
D-70 DEVELOPER 67-63-0
14807-96-6
MIL-I-25135,INSPECTION MATERIAL,PENETRANT
D-70 DEVELOPER 67-63-0
14807-96-6
FLUORO FINDER FL-2 8030-30-6
63-74-1
ZL-2A ZYGLO PENETRANT (PRE NOV 86) 68477-31-6
8008-20-6
206-44-0
ZL-2C ZYGLO PENETRANT 68477-31-6
8008-20-6
ZL-2D ZYGLO PENETRANT 64742-46-7
8008-20-6
68477-31-6
VP-131 PENETRANT(PRE 10/86) SEE SUPPL DATA
FP-93 A PENETRANT 64742-46-7
DP50 DYE PENETRANT
VP-30 PENETRANT
SKL-HF/SKL-S SPOTCHECK PENETRANT(PRE MAY86) 91-20-3
SKL-LO SPOTCHECK PENETRANT(LOW ODOR)POST 86 68477-31-6
64771-72-8
91-20-3
VP-31 PENETRANT(PRE 10/86)
VP-31A PENETRANT (POST 10/86) 64742-46-7
FLUORO-FINDER FL-17A PENETRANT (NSN CANCLD) 64742-94-5
117-81-7
206-44-0
FLUORO FINDER
ZL-15 ZYGLO PENETRANT (PRE 9/1985)NSN CNCLD
ZL-15B ZYGLO WATER WASH PENETRNT(POST 9/85) 64742-46-7
8008-20-6
64742-52-5
TURCO FLURO CHECK WP-1 PENETRANT 8002-05-9
FP-90 PENETRANTL
FLUORO-FINDER FL-22A PENETRANT (POST 3/84) 64742-94-5
117-81-7
206-44-0
URESCO 149A
ZL-22A ZYGLO PENETRANT (PRE 11/86)
ZL-22D ZYGLO PENETRANT (POST 11/86) 64742-46-7
8008-20-6
68477-31-6
ZL-27A ZYGLO PENETRANT 64742-46-7
8008-20-6
68477-31-6
FP-95 A PENETRANT 64742-46-7
FLUORO-FINDER EMULSIFIER FE-5 (PRE 12/88) 64742-06-9
71-55-6
TRACER TECH E-153 111-76-2
FLUORO FINDER FE-5 8030-30-6
71-43-2
ZE-3 ZYGLO EMULSIFIER (PRE 5/86) 8012-95-1
ZE-3 ZYGLO EMULSIFIER (POST 5/1986) 8012-95-1
ZE-4B ZYGLO EMULSIFIER 64742-52-5
98-55-5
TURCO FLURO-CHEK E EMULSIFIER
E-57 EMULSIFIER 64741-96-4
ZE-3 ZYGLO EMULSIFIER 8012-95-1
ZE-4B ZYGLO EMULSIFIER 64742-52-5
98-55-5
E-50 EMULSIFIER REMOVER 64742-88-7
64742-95-6
E-56 EMULSIFIER
RC65 FLUORESCENT PENETRANT 75-28-5
DR61 CLEANER/REMOVER 71-55-6
106-88-7
123-91-1
75-52-5
75-28-5
D100NF (D101NF) DEVELOPER 71-55-6
75-28-5
D100 DEVELOPER & D350 DEVELOPER 67-63-0
14807-96-6
75-28-5
FP-30 PENETRANT
TRACER TECH P149 INSPECTION PENETRANT 206-44-0
75-45-6
115-10-6
TRACER TECH P149 INSPECT PENETRANT REMOVER 71-55-6
124-38-9
75-45-6
115-10-6
TRACER TECH P149 INSPECT PENETRANT DEVELOPE 71-55-6
75-09-2
ZL-22A ZYGLO PENETRANT(PRE 1/87-SEE SUPPL) 124-38-9
SKC-NF/ZC-7 CLEANER (PRE 1/87-SEE SUPPL) 71-55-6
124-38-9
75-28-5
ZP-9B ZYGLO DEVELOPER (PRE 10/82-SEE SUPPL) 71-55-6

Free MSDS Search ( Providing 250,000+ Material Properties )
Chemcas.com| Ads link:todaystock.net