===================== Product Identification =====================
MSDS NAME:FLUORO-FINDER FL-17A PENETRANT (NSN CANCLD)
NIIN:00-782-2735
MSDS Number: BFPMF
=== Responsible Party ===
Company:AMERICAN GAS AND CHEMICAL CO.LTD.
Address:220 PEGASUS AVENUE
City:NORTHVALE
State:NJ
ZIP:07647-1904
Country:US
Info Phone Num:201-767-7300
Emergency Phone Num:201-767-7300
CAGE:03530
=== Contractor Identification ===
Company:AMERICAN GAS AND CHEMICAL COMPANY,LTD
Address:220 PEGASUS AVENUE,
City:N0RTHVALE
State:NJ
ZIP:07647-1904
Country:US
Phone:201-767-7300
CAGE:03530
============= Composition/Information on Ingredients =============
Name:HEAVY AROMATIC NAPHTHA (AROMATIC HYDROCARBONS SOLVENT, PER
MSDS)
CAS:64742-94-5
Fraction by Wt: 38.0%
Name:DI-SEC-OCTYL PHTHALATE (DI-2-ETHYLHEXYL-PHTHALATE) (SARA
III)
CAS:117-81-7
RTECS #:TI0350000
Fraction by Wt: 10.0%
OSHA PEL:5 MG/M3/10 STEL
ACGIH TLV:5 MG/M3; 9192
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Name:FLUORANTHENE (SARA III)
CAS:206-44-0
RTECS #:LL4025000
Fraction by Wt: 2.0%
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
===================== Hazards Identification =====================
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:UNKNOWN OSHA:YES
Explanation of Carcinogenicity:DI(2-ETHYLHEXYL)PHTHALATE IS LISTED AS
INDIRECT CARCINOGEN BY NIOSH AND NTP.
Effects of Overexposure:EYE:IRRITATTING; SKN:CAUSES
IRRITATION,DEFATTING,DERMATITIS; INHALATION:VAPOR CAUSES IRRITATION
TO REPIRATORY TRACT,DIZZINESS,AND EFFECTS CNS; INGESTION:CAUSES
VOMITING;POSSIBLE CHEM PNEUMONITIS.
Medical Cond Aggravated by Exposure:NONE KNOWN
======================= First Aid Measures =======================
First Aid:INHAL:REMOVE TO FRESH AIR. IF NOT BREATHING GIVE CPR; IF
BREATHING DIFFICULT GIVE OXYGEN. EYE:IMMEDIATELY FLUSH WITH PLENTY
OF WATER. SKIN:WASH WITH SOAP & WATER.REMOVE CONTAMINATED CLOTHING
& SHOES; INGESTION: DO NOT INDUCE VOMIT. NOTHINGBY MOUTH IF VICTIM
IS UNCONSCIOUS.GET MEDICAL HELP.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:150F/66C
Lower Limits:0.8
Upper Limits:6.0
Extinguishing Media:FOAM,DRY CHEMICAL,CO*2.WATER SPRAY OR FOG.
Fire Fighting Procedures:COOL WITH WATER SPRAY.USE SCBA WITH FULL
PROTECTION.
Unusual Fire/Explosion Hazard:USE REASONABLE CARE.AVOID STORING WITH
STRONG OXIDANTS,LIQUID CHLORINE OR CONC.O*2.
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE IGNITION SOURCES. RECOVER FREE LIQUID.
COLLECT SPILL W/ABSORBENT & PLACE IN CLOSED CONTAINERS.
====================== Handling and Storage ======================
Handling and Storage Precautions:KEEP CONTAINERS CLOSED. STORE IN COOL
AREA AWAY FROM HEAT & IGNITION SOURCES.GROUND LIQUID XFER SYSTEMS
PER NFPA PETROLEUM STANDARDS.
Other Precautions:COMBUSTIBLE LIQUID.HANDLE EMPTY CONTAINERS WITH
CARE.DO NOT CLEAN EMPTIES,RETURN TO DRUM RECONDITIONER, OR DISPOSE
SAFELY IAW ALL LAWS/REGS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE SAPP RESPIRATOR AS REQD IN CONFINED SPACES
Ventilation:USE HOOD FACE VEL >60 FPM.
Protective Gloves:CHEM RESIST
Eye Protection:GOGGLES OR FACE SHIELD
Other Protective Equipment:CHEM RESIST APRON OR IMPERV CLOTHING
Supplemental Safety and Health
I/A/W QPL-25135-13 OF MIL-I-25135,REV C, ITEM WAS OF GROUP IV WHICH NO
LONGER QUALIFIES FOR QPL-25135-15 UNDER REV E OF MIL-I-25135; HENCE
EFFECTIVE 89121, NSN HAS BEEN CANCELLED AND REPLACED BY 6850-
01-263-4055;UPDATE PER OSHA MSDS DTD 17JUN86.
================== Physical/Chemical Properties ==================
HCC:V4
Boiling Pt:B.P. Text:360F
Vapor Pres:<10
Vapor Density:4.8
Spec Gravity:0.92
Evaporation Rate & Reference:<0.1 (N-BUAC=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:YELLOW-GREEN LIQUID;MILD,AROMATIC ODOR.
Percent Volatiles by Volume:38
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS.
Stability Condition to Avoid:NONE SPECIFIED BY THE MFR
Hazardous Decomposition Products:CARBON MONOXIDE IN CASE OF INCOMPLETE
COMBUSTION
==================== Disposal Considerations ====================
Waste Disposal Methods:INCINERATE IN APPROVED FACILITY I/A/W ALL
APPLICABLE FEDERAL,STATE, AND LOCAL LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|