===================== Product Identification =====================
MSDS NAME:LAMINAR X-500 HRDNER(50-C-3)(2ND REFORMLTN)
NIIN:00-908-0362
Kit Part:Y
MSDS Number: BFVYY
=== Responsible Party ===
Company:MIDLAND DIVISION,THE DEXTER CORPORATION
Address:31500 HAYMAN ST
City:HAYWARD
State:CA
ZIP:94544-7120
Country:US
CAGE:98795
=== Contractor Identification ===
Company:DEXTER CORP THE DEXTER CROWN METRO AEROSPACE DIV
Address:31500 HAYMAN ST
Box:City:HAYWARD
State:CA
ZIP:94544-7120
Country:US
Phone:510-471-7171
CAGE:98795
============= Composition/Information on Ingredients =============
Name:TOLUENE-2,4-DIISOCYANATE (TDI) (SARA III)
CAS:584-84-9
RTECS #:CZ6300000
Fraction by Wt: 0.6%
OSHA PEL:C,0.02 PPM/0.02 STEL
ACGIH TLV:0.005PPM/0.02STEL;93
EPA Rpt Qty:100 LBS
DOT Rpt Qty:100 LBS
Name:1 METHOXY 2 PROPANOL ACETATE (CAS # 108-65-6)
Fraction by Wt: 25%
Name:XYLENES (O-,M-,P- ISOMERS) (SARA III)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 15%
OSHA PEL:100 PPM/150 STEL
ACGIH TLV:100 PPM/150STEL;9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
===================== Hazards Identification =====================
Effects of Overexposure:INH:ANESTH;IRRIT RESP TRACT,ACUTE CNS DEPRESS
W/HDCH,DIZ,STAG GAIT,CONFUS,UCON,COMA. SKIN/EYE:IRRIT
======================= First Aid Measures =======================
First Aid:FUMES: REMOVE FROM EXPOS. RESTORE BREATHING. KEEP WARM &
QUIET. NOTIFY MD. EYES:FLUSH IMMED W/COPIOUS QTY OF RUNNING WATER
AT LEAST 15 MIN. SEE MD FOR DEFINITIVE TREATMENT. SKIN:REMOVE
W/SOAP & WATER. REMOVE CONTAMINATED CLOTHING.
===================== Fire Fighting Measures =====================
Flash Point:92F SCC
Lower Limits:0.9
Extinguishing Media:CO*2,DRY CHEMICAL,FOAM FOR CLASS IB FLAM LIQ
Fire Fighting Procedures:USE WATER FOG TO COOL CLSD CONTAINERS EXPOS TO
FIRE.
Unusual Fire/Explosion Hazard:KEEP CANS TIGHTLY CLSD. KEEP FROM IGNIT
SOURCES. CLSD CANS MAY EXPLO FROM HEAT EXPOS. SEE OTHER PREC
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION(FLAMES,HOT
SURFACES, & ELECTRICAL,STATIC OR FRICTIONAL SPARKS). AVOID
BREATHING VAPORS. VENTILATE AREA. REMOVE W/INERT ABSORBENT &
NON-SPARKING TOOLS.
====================== Handling and Storage ======================
Handling and Storage Precautions:DO NOT STORE ABOVE 120F. STORE LG QTY
IN BUILDINGS DESIGN FOR STORAGE OF NFPA CLASS II FLAM LIQ. DO NOT
TAKE INTERNALLY. GROUND CONTAINER WHEN POURING
Other Precautions:AVOID FREE FALL OF LIQ IN EXCESS OF A FEW INCHES. DO
NOT FLAME CUT,BRAZE,OR WELD W/O NIOSH APROVED RESP OR APPROP
VENTILATION. UNUSUAL FIRE/EXPLO HAZ: DO NOT APPLY TO HOT SURFACES.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH/MSHA APPRVD RESP PROT REQD. VARIES
W/CONDITIONS OF USE.
Ventilation:GEN DILTN/LOC EXHST IN VOLUME & PATTERN TO KEEP 1.0
Spec Gravity:1.1057
Evaporation Rate & Reference:SLOWER THAN ETHER
Percent Volatiles by Volume:48
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:SOURCES OF IGNITION
Hazardous Decomposition Products:FUMES FROM HEATING TO DECOMP:CO,OXIDES
OF NITROGEN.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOS OF IAW LOCAL, STATE & FEDERAL
REGULATIONS. DO NOT INCINERATE CLOSED CONTAINERS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|