===================== Product Identification =====================
MSDS NAME:7018XLM(E7018)
NIIN:01-039-3494
MSDS Number: BGGYR
=== Responsible Party ===
Company:TELEDYNE MCKAY
Emergency Phone Num:717-845-7581
CAGE:76254
=== Contractor Identification ===
Company:HOBART BROS CO MCKAY WELDING PRODUCTS DIV
Address:400 TRADE SQ E
Box:City:TROY
State:OH
ZIP:45373-2900
Country:US
Phone:513-332-5706
CAGE:76254
============= Composition/Information on Ingredients =============
Name:IRON AS FILLER, CAS #7439-89-6; TLV AS RESPIRABLE FUME
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: >90%
ACGIH TLV:5 MG/CUM (FUME)
Name:MANGANESE (SARA III)
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: 1.1%
OSHA PEL:(C) 5 MG/M3 DUST
ACGIH TLV:5 MG/M3 DUST 9293
Name:SILICON
CAS:7440-21-3
RTECS #:VW0400000
Fraction by Wt: 0.5%
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293
Name:CALCIUM FLUORIDE
CAS:7789-75-5
RTECS #:EW1760000
OSHA PEL:2.5 MG/M3 (F)
ACGIH TLV:2.5 MG/M3 (F); 8990
Name:ALUMINUM (SARA III)
CAS:7429-90-5
RTECS #:BD0330000
OSHA PEL:15MG/M3 DUST/5 FUME
ACGIH TLV:10MG/M3 DUST; 9192
===================== Hazards Identification =====================
Effects of Overexposure:INHAL: METAL FUME FEVER, DRY THROAT, FATIGUE,
HEADACHE, IRRITATION OF NOSE/THROAT/EYES; NAUSEA.
======================= First Aid Measures =======================
First Aid:INHAL: REMOVE TO FRESH AIR- GIVE O*2/CPR AS SITUATION
DICTATES.
===================== Fire Fighting Measures =====================
Extinguishing Media:EXTINGUISH WITH AGENT SUITABLE FOR SURROUNDING FIRE
Unusual Fire/Explosion Hazard:WELDING ARC AND SPARK (SPATTER) CAN
IGNITE COMBUSTIBLE AND FLAMMABLE MATERIALS.
================== Accidental Release Measures ==================
Spill Release Procedures:SWEEP UP RODS AND PLACE IN APPROPRIATE
CONTAINER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL,DRY WELL VENTED,LOW FIRE
RISK AREA. PROTECT FR HEAT,SHOCK KEEP CONTAINERS CLOSED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:NIOSH APPRVD RESPIRABLE FUME RESPIRATOR,OR SCBA'
IN CONFINED SPACE.
Ventilation:PROVIDE MECHAN(GEN/LOCAL EXHAUST)VENT TO MAINTN
| |