===================== Product Identification =====================
MSDS NAME:BRAYCOTE 646
NIIN:00-687-4241
MSDS Number: BGXCZ
=== Responsible Party ===
Company:CASTROL INC.,BRAY PRODUCTS DIV.
Address:16715 VON KARMAN AVE.,SUITE230
City:IRVINE
State:CA
ZIP:92714
Country:US
Info Phone Num:714-660-9414
Emergency Phone Num:714-660-9414
Preparer's Name:KAREL WRIGHT
CAGE:EO288
=== Contractor Identification ===
Company:CASTROL INC.,BRAY PRODUCTS DIV.
Address:16715 VON KARMAN AVE.,SUITE 230
City:IRVINE
State:CA
ZIP:92714
Country:US
Phone:714-660-9414/ABROAD 202-4837616COLL
CAGE:EO288
Company:CASTROL INDUSTRIAL NORTH AMERICA INC SPECIALTY PRODUCTS
DIV
Address:1001 WEST 31ST STREET
Box:City:DOWNERS GROVE
State:IL
ZIP:60515-1280
Country:US
Phone:800-621-2661/ FAX: 630-241-4140
CAGE:2R128
============= Composition/Information on Ingredients =============
Name:SYNTHETHIC ESTER
Other REC Limits:5MG/CUM AS OIL MIST
Name:DIISOPROPYL HYDROGEN PHOSPHITE
CAS:1809-20-7
RTECS #:SZ7660000
Fraction by Wt: <2.0%
Name:OTHER COMPONENTS (TYPE NOT SPECIFIED)
===================== Hazards Identification =====================
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:IRRITATION OF
EYES,REDNESS,TEARING,SKIN IRRITATION,DEFATING AND RESPIRATORY
IRRITATION. CHRONIC:IRRITATION OF SKIN,DERMATITIS,DEFATTING.
Explanation of Carcinogenicity:PER MSDS
Effects of Overexposure:SEE HEALTH HAZARDS DATA.
Medical Cond Aggravated by Exposure:NONE KNOWN TO MFR.
======================= First Aid Measures =======================
First Aid:EYE:FLUSH WITH PLENTY OF WATER FOR ABOUT 15 MINUTES;SEEK
MEDICAL ATTENTION. SKIN:DO NOT USE CONTAMINATED CLOTHES;WASH
THOROUGHLY WITH SOAP & WATER. INHALATION:REMOVE TO FRESH AIR;SEEK
MEDICAL HELP. IN GESTION:DO NOT INDUCE VOMITING;CONSULT A PHYSICIAN
IMMEDIATELY.
===================== Fire Fighting Measures =====================
Flash Point Method:COC
Flash Point:500F/260C
Extinguishing Media:DRY CHEMICAL,CO*2,FOAM.
Fire Fighting Procedures:FIRE FIGHTERS SHOULD USE NIOSH APPROVED SCBA &
FULL PROTECTIVE EQUIPMENT WHEN FIGHTING CHEMICAL FIRE. USE WATER
SPRAY TO COOL NEARBY CONTAINERS EXPOSED TO FIRE.
Unusual Fire/Explosion Hazard:NONE NOTED BY MFR.
================== Accidental Release Measures ==================
Spill Release Procedures:USE PROPER PERSONAL PROTECTION;REMOVE ALL
IGNITION SOURCES;CONTAIN FREE LIQUID IF POSSIBLE;USE SUITABLE INERT
ABSORBENT MATERIAL AND RECOVER FOR PROPER DISPOSAL.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN COOL,DRY AND WELL VENTILATED
AREA;KEEP AWAY FROM HEAT,FLAMES,STRONG OXIDIZERS;KEEP CONTAINER
TIGHTLY CLOSED WHEN NOT IN USE.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR FOR ORGANIC
VAPORS/MIST IF ABOVE PEL/TLV.
Ventilation:LOCAL EXHAUST/GENERAL TO MAINTAIN PEL/TLV.
Protective Gloves:NEOPRENE.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:IMPERVIOUS APRON OR UNIFORM;EYE-WASH
FACILITIES.
Work Hygienic Practices:AVOID CONTACT WITH EYES & SKIN;DO NOT BREATHE
VAPORS/MIST;WASH THOROUGHLY AFTER EACH USE;DO NOT USE CONTAMINATED
CLOTHES
Supplemental Safety and Health
.
================== Physical/Chemical Properties ==================
HCC:V6
Boiling Pt:B.P. Text:>600F/316C
Spec Gravity:0.93
Solubility in Water:NEGLIGIBLE
Appearance and Odor:TAN SEMI-FLUID COMPOUND,MILD ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS
Stability Condition to Avoid:HIGH TEMPERATURES, SPARKS, AND OPEN FLAMES
Hazardous Decomposition Products:SMOKE,FUMES,CO & CO*2,MINOR AMOUNTS OF
VARIOUS HYDRO-CARBONS,OXIDES OF SULFUR.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSE OF BY METHOD IN COMPLIANCE WITH
LOCAL,STATE AND FEDERAL REGULATIONS FOR HEALTH,AIR AND WATER
POLLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.
*** END OF RECORD *** |
|